TC-FOD161 Honeywell 24 VDC Digital Output Module

SKU: TC-FOD161

Technical specifications

  • Manufacturer: Honeywell

  • Condition:New with Original Package

  • Product Type: Digital Output Modules

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

By submitting a request for this item, you confirm that you have reviewed and accepted our Terms & Conditions. Please note that all transactions will be processed offline.

100% Original and Authentic
100% Brand New, Ready to ship
Support Refund, 7X24h Service
1-Year Warranty on All Products

Help us reach more people! Share this product with your network and show your support!

Product Description

The Honeywell TC-FOD161 is a 16-channel, 24 VDC source digital output module designed to switch DC loads in industrial control systems. It provides one non-isolated group of 16 protected output channels, with individual channel status indicators for monitoring output activity. The module supports output currents up to 500 mA per channel and includes specified surge-current capability and output switching delay limits.

Technical Specifications

Parameter Specification
Model TC-FOD161
Brand Honeywell
Product Type Protected Digital Output Module
Output Type 24 VDC source digital output
Number of Channels 16
Channel Configuration 1 group of 16 channels
Channel Isolation Non-isolated between individual channels
Module Location DIN-rail mounted
ON-State Voltage 10 VDC minimum; 24 VDC nominal; 31.2 VDC maximum
ON-State Current 1 mA minimum per channel; 500 mA maximum per channel
OFF-State Voltage Drop 0.5 VDC maximum
OFF-State Leakage Current 0.5 mA maximum
Surge Current 1.5 A for 50 ms, repeatable every 2 s
OFF-to-ON Delay 0.5 ms maximum
ON-to-OFF Delay 1.0 ms maximum
Dielectric Withstand Test 850 VDC for 1 s between user and system; 100% tested
Flexbus Current 80 mA maximum
Power Dissipation 5 W at 31.2 VDC
Thermal Dissipation 17 BTU/hr at 31.2 VDC
Channel Indicators 16 yellow channel status indicators
External DC Supply Voltage 19.2-31.2 VDC
External DC Supply Ripple 5% AC ripple
External DC Supply Current 80 mA
Dimensions (H x W x D) 69 x 94 x 80 mm (2.72 x 3.70 x 3.20 in)
Operating Temperature 0 to 55 deg C (32 to 131 deg F)
Storage Temperature -40 to 85 deg C (-40 to 185 deg F)

Output Configuration and Load Requirements

The TC-FOD161 uses a sourcing output arrangement to deliver positive DC voltage to connected loads when the outputs are activated. Each channel supports a specified ON-state current range, with a maximum of 500 mA per channel. The actual load current must remain within the channel rating and the external supply limits.

The module provides 16 outputs in one non-isolated group. Therefore, individual channels do not have galvanic isolation from one another. The specified dielectric withstand test applies between the user side and the system side; it does not indicate isolation between output channels.

Electrical Protection and Switching Performance

The specified surge capability is 1.5 A for 50 ms, repeatable every 2 seconds. This rating describes a defined transient condition and should not be treated as the continuous output current rating. The maximum OFF-state leakage current and voltage drop are also relevant when selecting connected loads, particularly where a load may respond to small residual currents.

The module specifies a maximum switching delay of 0.5 ms from OFF to ON and 1.0 ms from ON to OFF. These values help establish whether the output response is suitable for the controlled device. They do not, by themselves, establish the complete response time of the control system.

Power and Environmental Requirements

The external DC supply must remain within the specified 19.2-31.2 VDC range, with 5% AC ripple. At the maximum stated operating voltage of 31.2 VDC, the module's specified power dissipation is 5 W and its thermal dissipation is 17 BTU/hr. These values should be considered when checking the installation's electrical supply and thermal conditions.

The operating temperature range is 0 to 55 deg C, while the storage range extends from -40 to 85 deg C. The module also has specified humidity, shock, and vibration limits. Installation conditions should remain within these ratings for the intended operating environment.

Frequently Asked Questions

Q: How many output channels does the Honeywell TC-FOD161 provide?

A: It provides 16 protected 24 VDC sourcing output channels arranged in one non-isolated group.

Q: What is the maximum continuous output current per channel?

A: The specified maximum ON-state current is 500 mA per channel. The separate 1.5 A surge rating applies only to the stated 50 ms transient condition, repeatable every 2 seconds.

Q: Are the 16 output channels electrically isolated from each other?

A: No. The individual channels are not isolated from one another. The 850 VDC dielectric withstand test applies between the user and system sides, not between individual output channels.

Other Attributes

  • Series: Honeywell Experion PKS(C200,C300)
  • Country of Origin:  USA
  • Lead Time: In Stock, 2 Working Days

 

In Stock Hot Items of Honeywell

FC-SDO-1624 8C-PAIH51 MC-TAMR03 51309218-175
FC-TSDI-1624 8C-PAIH51*E MC-TAOY22 51204172-175
FC-TSDO-1624 8C-PAIH52 MU-TMCN02 561401846-200
FS-TSAI-1620M 8C-PAIN01 MC-TAIH02 51304453-150
FS-TSDI-1624 8C-PAOH51 MC-TAIL02 51304437-150
FC-RUSIO-3224 8C-PAON01 MC-TDID72 51303928-150
FC-SDI-1624 8C-PCNT01 MC-TDODI3 51304650-150
FC-BKM-0001 8C-PDIL51 MC-TDOY23 51204166-175
FC-IO-0001 8C-PDILAI MU-KLAM06 51304465-400
FC-PSU-UNI2450U 8C-PDOD51 MU-TAIH02 51304453-100
FC-QPP-0001 8C-TAID51 MU-TAMR03 501309218-125
FC-SAI-1620M 8C-TAIX51 MU-TAOX12 51304335-100
FC-USI-0001 8C-TAIX61 MU-TDID72 51303928-100
CC-PAOX01 8C-TAOX61 MU-TDOD12 51304423-100
CC-PFB801 8C-TCNT01 MU-TDOR22 51304427-100
CC-PPIX01 TC-CCN013 DC-TFB412 51307618-176
CC-TAID11 TC-CCR012 TK-IOLI01 51403427-175 
DC-TAOX11 TC-IAH161 TK-PPD011 51309241-175 
TC-IDJ161 TC-OAV081 TK-PRS021 51404305-275 
TC-IXL061 10300/1/1 CC-TAIX01 51308363-175
TDCS3000LCN 51305887-150 8C-PAOHA1 51454469-275
TK-FPDXX2 10012/1/2 8C-PAIMA1 51454473-175

 

Our Competitive Brands

  • - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
  • - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
  • - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
  • - Bently Nevada 3300 System, 3500 System
  • - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
  • - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
  • - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider

 

TEL: +86 18030205725     E-MAIL: manskiwong@cambia.cn

Question 1: Is Our Price Competitive?

NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.

Question 2: What Is The Warranty Period?

We offer a standard one-year warranty for all new and original items.

Question 3: What Payment Methods Do We Accept?

We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.

Question 4: What Shipping Methods Do We Use?

We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.

Question 5: What Is Our Delivery Time?

Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.

Question 6: How Do We Package The Goods?

Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.

Question 7: How Can Customers Contact Us And Request A Quote?

Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.