MC-TAMR04 51305907-175 Honeywell UCN Low Level Analog Input Multiplexer

SKU: MC-TAMR04 51305907-175

Technical specifications

  • Manufacturer: Honeywell

  • Condition:New with Original Package

  • Product Type: Analog Input Modules

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

By submitting a request for this item, you confirm that you have reviewed and accepted our Terms & Conditions. Please note that all transactions will be processed offline.

100% Original and Authentic
100% Brand New, Ready to ship
Support Refund, 7X24h Service
1-Year Warranty on All Products

Help us reach more people! Share this product with your network and show your support!

Product Description

Configured for low-level thermocouple signal multiplexing in Honeywell UCN-based TPS/Experion PKS architectures, the Honeywell 51305907-175, also cataloged as the MC-TAMR04 Low Level Analog Input Multiplexer, provides direct physical/electrical execution of microvolt-range sensor acquisition and channel switching.

Hardware Specifications

Parameter Specification
Model MC-TAMR04 51305907-175
Brand Honeywell
Origin USA
Weight 0.7 kg
Dimensions 30.5 x 11.9 x 7 cm
Operating Temp 0 to 60 deg C (typical DCS cabinet ambient)
Power Consumption 15 W typical, 20 W maximum
Input Impedance >10 MΩ
Resolution 24-bit ADC
Accuracy ±0.02% of reading ±1 μV
Common Mode Rejection >140 dB @ 50/60 Hz
Tariff Code 8537101190

Cold Junction Compensation and Thermocouple Signal Conditioning

The module executes cold junction compensation (CJC) locally at the terminal block reference using an onboard precision temperature sensor, then offsets the raw thermocouple EMF against the CJC value before 24-bit conversion. Channel-to-channel isolation is maintained through galvanic barrier structure between the LLMUX FTA TC SLD ST.CC front-end and the UCN backplane, suppressing ground-loop injection from field wiring. Input scanning follows a sequential multiplexer schedule driven by the UCN controller; each thermocouple channel is sampled with auto-zero correction to cancel offset drift across the 0 to 60 deg C cabinet range.

Frequently Asked Questions

Q: Does the MC-TAMR04 support hot-swap replacement on a live UCN I/O link without controller restart?

A: No. The module must be de-energized at the cabinet power supply before extraction. Live removal disrupts the UCN node token and forces a re-scan cycle on the associated controller redundant pair.

Q: What is the backplane current draw contributed by one MC-TAMR04 at 5 VDC and 24 VDC rails?

A: Typical 15 W load distributes as approximately 1.2 A at 12 VDC internal conversion input from the cabinet power supply; no direct 5 VDC backplane current is drawn because the ADC and CJC subsystems are locally regulated from the 12 VDC intermediate rail.

Q: Can Type-K and Type-J thermocouples be mixed on the same MC-TAMR04 physical module?

A: Yes, per-channel linearization table selection is software-assigned in the DCS database. However, the CJC reference is shared per FTA block, so mixed types are allowed only if all connected probes share the same terminal block ambient environment.

Field Installation Guidelines

Mount the module into the designated UCN I/O carrier slot with the cabinet power isolated. Seat the LLMUX FTA TC SLD ST.CC terminal assembly first, then insert the MC-TAMR04 until the guide rails lock. Ground the shield drain wire of each thermocouple cable to the DCS cabinet ground bus at the single-point shield termination strip; do not tie shield to terminal block signal common. Keep thermocouple extension wires away from 120 VAC and 24 VDC solenoid wiring by minimum 150 mm separation or metal partition. Verify CJC accuracy by shorting one spare channel input to the CJC reference screw and confirming sub-2 μV offset after 30 min cabinet stabilization at 25 deg C.

 

Other Attributes

  • Series: Honeywell C200 C300
  • Country of Origin:  USA
  • Lead Time: In Stock, 2 Working Days

 

In Stock Hot Items of Honeywell

FC-SDO-1624 8C-PAIH51 MC-TAMR03 51309218-175
FC-TSDI-1624 8C-PAIH51*E MC-TAOY22 51204172-175
FC-TSDO-1624 8C-PAIH52 MU-TMCN02 561401846-200
FS-TSAI-1620M 8C-PAIN01 MC-TAIH02 51304453-150
FS-TSDI-1624 8C-PAOH51 MC-TAIL02 51304437-150
FC-RUSIO-3224 8C-PAON01 MC-TDID72 51303928-150
FC-SDI-1624 8C-PCNT01 MC-TDODI3 51304650-150
FC-BKM-0001 8C-PDIL51 MC-TDOY23 51204166-175
FC-IO-0001 8C-PDILAI MU-KLAM06 51304465-400
FC-PSU-UNI2450U 8C-PDOD51 MU-TAIH02 51304453-100
FC-QPP-0001 8C-TAID51 MU-TAMR03 501309218-125
FC-SAI-1620M 8C-TAIX51 MU-TAOX12 51304335-100
FC-USI-0001 8C-TAIX61 MU-TDID72 51303928-100
CC-PAOX01 8C-TAOX61 MU-TDOD12 51304423-100
CC-PFB801 8C-TCNT01 MU-TDOR22 51304427-100
CC-PPIX01 TC-CCN013 DC-TFB412 51307618-176
CC-TAID11 TC-CCR012 TK-IOLI01 51403427-175 
DC-TAOX11 TC-IAH161 TK-PPD011 51309241-175 
TC-IDJ161 TC-OAV081 TK-PRS021 51404305-275 
TC-IXL061 10300/1/1 CC-TAIX01 51308363-175
TDCS3000LCN 51305887-150 8C-PAOHA1 51454469-275
TK-FPDXX2 10012/1/2 8C-PAIMA1 51454473-175

 

Our Competitive Brands

  • - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
  • - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
  • - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
  • - Bently Nevada 3300 System, 3500 System
  • - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
  • - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
  • - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider

 

TEL: +86 18030205725     E-MAIL: manskiwong@cambia.cn

Question 1: Is Our Price Competitive?

NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.

Question 2: What Is The Warranty Period?

We offer a standard one-year warranty for all new and original items.

Question 3: What Payment Methods Do We Accept?

We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.

Question 4: What Shipping Methods Do We Use?

We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.

Question 5: What Is Our Delivery Time?

Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.

Question 6: How Do We Package The Goods?

Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.

Question 7: How Can Customers Contact Us And Request A Quote?

Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.