Product Description
The CC-PAOH01 51405039-175 is a Honeywell HART analog output module designed to provide 16-channel current outputs for industrial control applications. It supports 4-20 mA analog signaling and HART communication, allowing the control system to transmit output commands to compatible field devices. The module operates with a 24 VDC supply and provides configurable output current ranges, readback, and specified accuracy characteristics for analog control applications.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | CC-PAOH01 51405039-175 |
| Spare Part Number | 51405039-175 |
| Brand | Honeywell |
| Product Type | HART Analog Output Module |
| Output Channels | 16 |
| Output Type | Analog current |
| Output Signal | 4-20 mA |
| Supply Voltage | 24 VDC |
| Rated Current | 0.46 A |
| Output Temperature Drift | 0.005% of full scale/deg C |
| Output Readback Accuracy | +/- 4% of full scale |
| Output Current Linearity | +/- 0.05% of full scale, nominal |
| Resolution | +/- 0.05% of full scale |
| Directly Settable Output Current Range | 0 mA, 2.9 mA to 21.1 mA |
| Maximum Resistive Load | 800 ohms |
| Maximum Output Compliance Voltage | 16 V |
| Maximum Open-Circuit Voltage | 22 V |
| Country of Origin | USA |
| Shipping Location | Xiamen, China |
| Shipping Dimensions | 6 x 15.5 x 14.5 cm |
| Weight | 0.4 kg |
| Tariff Code | 8537101190 |
Output Channels and HART Communication
The CC-PAOH01 provides 16 analog output channels for transmitting current signals from the control system to compatible field devices. The standard 4-20 mA signal supports analog command transmission, while HART communication enables digital communication over compatible current-loop connections. Actual HART functionality depends on the connected field device and the configured control system.
Output Range and Load Conditions
The directly settable output range extends from 0 mA to 2.9-21.1 mA, as specified in the supplied data. This range provides configurable current values beyond the nominal 4-20 mA operating span. When selecting field devices, check the required signal range and ensure that the total loop resistance remains within the module's maximum resistive load rating of 800 ohms.
The maximum output compliance voltage is 16 V, while the maximum open-circuit voltage is 22 V. These limits describe different output conditions and should not be treated as interchangeable ratings. Confirm the field device's input requirements and loop voltage drop before commissioning.
Accuracy and Signal Quality
The module's specified calibrated accuracy is +/- 0.35% of full scale at 25 deg C, including linearity. However, the separately listed output readback accuracy is +/- 4% of full scale. These figures describe different specifications and should not be combined into a single accuracy value without further technical clarification.
The specified output current linearity and resolution are each +/- 0.05% of full scale. The output temperature drift is 0.005% of full scale per deg C. These parameters help engineers assess analog signal performance, although the complete measurement and control loop accuracy also depends on the field device, wiring, and system configuration.
Frequently Asked Questions
Q: How many analog output channels does the CC-PAOH01 provide?
A: The module provides 16 analog output channels. Each channel is intended for current-signal control, with a nominal 4-20 mA output range.
Q: Can the CC-PAOH01 communicate with HART field devices?
A: The module is identified as a HART analog output module. Confirm compatibility with the specific field device and control system configuration before using HART communication.
Q: What load resistance can the CC-PAOH01 support?
A: The specified maximum resistive load is 800 ohms. The actual permissible loop resistance also depends on the connected device and the available output compliance voltage.
Other Attributes
- Series: Honeywell Experion PKS(C200,C300)
- Country of Origin: USA
- Lead Time: In Stock, 2 Working Days
In Stock Hot Items of Honeywell
| FC-SDO-1624 | 8C-PAIH51 | MC-TAMR03 51309218-175 |
| FC-TSDI-1624 | 8C-PAIH51*E | MC-TAOY22 51204172-175 |
| FC-TSDO-1624 | 8C-PAIH52 | MU-TMCN02 561401846-200 |
| FS-TSAI-1620M | 8C-PAIN01 | MC-TAIH02 51304453-150 |
| FS-TSDI-1624 | 8C-PAOH51 | MC-TAIL02 51304437-150 |
| FC-RUSIO-3224 | 8C-PAON01 | MC-TDID72 51303928-150 |
| FC-SDI-1624 | 8C-PCNT01 | MC-TDODI3 51304650-150 |
| FC-BKM-0001 | 8C-PDIL51 | MC-TDOY23 51204166-175 |
| FC-IO-0001 | 8C-PDILAI | MU-KLAM06 51304465-400 |
| FC-PSU-UNI2450U | 8C-PDOD51 | MU-TAIH02 51304453-100 |
| FC-QPP-0001 | 8C-TAID51 | MU-TAMR03 501309218-125 |
| FC-SAI-1620M | 8C-TAIX51 | MU-TAOX12 51304335-100 |
| FC-USI-0001 | 8C-TAIX61 | MU-TDID72 51303928-100 |
| CC-PAOX01 | 8C-TAOX61 | MU-TDOD12 51304423-100 |
| CC-PFB801 | 8C-TCNT01 | MU-TDOR22 51304427-100 |
| CC-PPIX01 | TC-CCN013 | DC-TFB412 51307618-176 |
| CC-TAID11 | TC-CCR012 | TK-IOLI01 51403427-175 |
| DC-TAOX11 | TC-IAH161 | TK-PPD011 51309241-175 |
| TC-IDJ161 | TC-OAV081 | TK-PRS021 51404305-275 |
| TC-IXL061 | 10300/1/1 | CC-TAIX01 51308363-175 |
| TDCS3000LCN | 51305887-150 | 8C-PAOHA1 51454469-275 |
| TK-FPDXX2 | 10012/1/2 | 8C-PAIMA1 51454473-175 |
Our Competitive Brands
- - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
- - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
- - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
- - Bently Nevada 3300 System, 3500 System
- - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
- - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
- - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider
Question 1: Is Our Price Competitive?
NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.
Question 2: What Is The Warranty Period?
We offer a standard one-year warranty for all new and original items.
Question 3: What Payment Methods Do We Accept?
We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.
Question 4: What Shipping Methods Do We Use?
We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.
Question 5: What Is Our Delivery Time?
Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.
Question 6: How Do We Package The Goods?
Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.
Question 7: How Can Customers Contact Us And Request A Quote?
Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.
Download the product documentation:
Click here to view or download the PDF