FC-TDOL-0724 Honeywell Digital Output FTA
Technical specifications
Manufacturer: Honeywell
Condition:New with Original Package
Product Type: Digital Output Field Termination Assemblies
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
By submitting a request for this item, you confirm that you have reviewed and accepted our Terms & Conditions. Please note that all transactions will be processed offline.
Ask an expert
Help us reach more people! Share this product with your network and show your support!
Product Description
The Honeywell FC-TDOL-0724, also identified as the FC-TDOL-0724 Digital Output FTA, provides seven line-monitored relay contact output channels for discrete field circuit control. The assembly includes one relay with an indicator LED, a fused contact output rated at 2 A time-delay (2 AT), and a 22 kOhm current injection resistor. The supplied data lists 120 VAC or 120 VDC +/- 20% output supply voltage; verify field wiring and load compatibility against the applicable hardware documentation.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | FC-TDOL-0724 |
| Spare Model | FC-TDOL-0724 |
| Brand | Honeywell |
| Product Type | Digital Output Field Termination Assembly (FTA) |
| Origin | USA |
| Weight | 0.62 kg |
| Dimensions | 24 x 10.8 x 8.5 cm |
| Number of Channels | 7 |
| Output Supply Voltage | 120 VAC or 120 VDC +/- 20% (as supplied) |
| Relay Output | Line-monitored relay contact |
| Indicator | One relay indicator LED |
| Contact Fuse | 2 AT |
| Current Injection Resistor | 22 kOhm |
| Minimum Required Field Load | 1 W |
| Leakage Current to Load | Maximum 1 mA at 120 V |
| Short-Circuit Detection Load Threshold | 200 Ohm < RTh < 400 Ohm |
| Maximum Load Capacitance | 1 uF |
| AC Voltage Rating | 250 V |
| DC Voltage Rating | 300 V |
| Approvals | CE, UL, CSA, TUV |
| Tariff Code | 8537101190 |
Line Monitoring and Relay Output Characteristics
The FC-TDOL-0724 uses relay contacts for discrete output switching and incorporates line-monitoring components. The 22 kOhm current injection resistor supports the specified monitoring circuit, while the fused contact output provides a 2 AT fuse rating. The relay indicator LED provides a local visual indication; its exact relationship to relay energization or output status should be verified against the manufacturer's documentation.
The listed leakage current, field-load requirement, load capacitance, and short-circuit detection threshold define electrical considerations for field circuit selection. The stated voltage ratings must not be confused with the operating supply voltage.
Frequently Asked Questions (FAQ)
Q: How many output channels does the FC-TDOL-0724 provide?
A: The supplied specifications identify seven channels in the digital output FTA.
Q: What components support line monitoring?
A: The listed hardware includes a 22 kOhm current injection resistor and a line-monitored relay contact output. Confirm the complete monitoring circuit and field wiring arrangement using the manufacturer's wiring documentation.
Q: What voltage should be applied to the output circuits?
A: The supplied data lists 120 VAC or 120 VDC +/- 20% and separate AC and DC voltage ratings. Confirm the applicable circuit configuration and terminal ratings before energizing the assembly.
Field Installation Guidelines
- Verify the module model and terminal assignments against the applicable Honeywell installation documentation.
- Confirm the required field supply voltage and distinguish operating voltage from the maximum AC and DC voltage ratings.
- Check field-load power, leakage-current tolerance, and load capacitance before connecting external devices.
- Verify fuse type and rating before installation. The supplied specification identifies a 2 AT contact fuse.
- Route field signal wiring separately from high-noise power conductors where practical. Apply the cabinet grounding and cable-shielding practices specified for the installed control system.
- Inspect terminal connections and verify circuit continuity before energizing the assembly.
- Test relay switching, LED indication, and line-monitoring behavior according to the approved commissioning procedure.
Other Attributes
- Series: Honeywell Experion PKS(C200,C300)
- Country of Origin: USA
- Lead Time: In Stock, 2 Working Days
In Stock Hot Items of Honeywell
| FC-SDO-1624 | 8C-PAIH51 | MC-TAMR03 51309218-175 |
| FC-TSDI-1624 | 8C-PAIH51*E | MC-TAOY22 51204172-175 |
| FC-TSDO-1624 | 8C-PAIH52 | MU-TMCN02 561401846-200 |
| FS-TSAI-1620M | 8C-PAIN01 | MC-TAIH02 51304453-150 |
| FS-TSDI-1624 | 8C-PAOH51 | MC-TAIL02 51304437-150 |
| FC-RUSIO-3224 | 8C-PAON01 | MC-TDID72 51303928-150 |
| FC-SDI-1624 | 8C-PCNT01 | MC-TDODI3 51304650-150 |
| FC-BKM-0001 | 8C-PDIL51 | MC-TDOY23 51204166-175 |
| FC-IO-0001 | 8C-PDILAI | MU-KLAM06 51304465-400 |
| FC-PSU-UNI2450U | 8C-PDOD51 | MU-TAIH02 51304453-100 |
| FC-QPP-0001 | 8C-TAID51 | MU-TAMR03 501309218-125 |
| FC-SAI-1620M | 8C-TAIX51 | MU-TAOX12 51304335-100 |
| FC-USI-0001 | 8C-TAIX61 | MU-TDID72 51303928-100 |
| CC-PAOX01 | 8C-TAOX61 | MU-TDOD12 51304423-100 |
| CC-PFB801 | 8C-TCNT01 | MU-TDOR22 51304427-100 |
| CC-PPIX01 | TC-CCN013 | DC-TFB412 51307618-176 |
| CC-TAID11 | TC-CCR012 | TK-IOLI01 51403427-175 |
| DC-TAOX11 | TC-IAH161 | TK-PPD011 51309241-175 |
| TC-IDJ161 | TC-OAV081 | TK-PRS021 51404305-275 |
| TC-IXL061 | 10300/1/1 | CC-TAIX01 51308363-175 |
| TDCS3000LCN | 51305887-150 | 8C-PAOHA1 51454469-275 |
| TK-FPDXX2 | 10012/1/2 | 8C-PAIMA1 51454473-175 |
Our Competitive Brands
- - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
- - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
- - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
- - Bently Nevada 3300 System, 3500 System
- - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
- - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
- - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider
Question 1: Is Our Price Competitive?
NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.
Question 2: What Is The Warranty Period?
We offer a standard one-year warranty for all new and original items.
Question 3: What Payment Methods Do We Accept?
We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.
Question 4: What Shipping Methods Do We Use?
We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.
Question 5: What Is Our Delivery Time?
Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.
Question 6: How Do We Package The Goods?
Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.
Question 7: How Can Customers Contact Us And Request A Quote?
Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.