10106/2/1 Honeywell FSC Series Fail-Safe Digital Input Module
Technical specifications
Manufacturer: Honeywell
Condition:New with Original Package
Product Type: Digital Input Modules
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
By submitting a request for this item, you confirm that you have reviewed and accepted our Terms & Conditions. Please note that all transactions will be processed offline.
Ask an expert
Help us reach more people! Share this product with your network and show your support!
Product Description
The Honeywell 10106/2/1, also identified as the 10106/2/1 digital input module, monitors 16 discrete input channels using DIN 19234 (NAMUR) signal characteristics. The module operates with a 24 VDC supply requirement and detects input states through defined current switching thresholds. Its fail-safe designation identifies the module type; specific safety response behavior must be verified against the applicable system documentation.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 10106/2/1 |
| Brand | Honeywell |
| Module Type | Fail-Safe Digital Input Module |
| Origin | USA |
| Weight | 0.12 kg |
| Estimated Shipping Size | 2 x 18.8 x 12.7 cm |
| Operating Temp | Not specified |
| Power Consumption | 5 VDC at 160 mA; 24 VDC at 110 mA |
| Number of Input Channels | 16 |
| Input Type | DIN 19234 (NAMUR) |
| Switch Level | 1.4 to 1.9 mA |
| Hysteresis | 0.2 mA +/- 0.05 mA |
| Field Wire Resistance | Maximum 50 Ohm |
| Output Voltage | 7.9 to 8.7 V |
| Output Current | 170 mA |
| Space Requirements | 4 TE, 3 HE (4 HP, 3U) |
| Safety Class | AK1-6 |
| Software Version | 510 or later |
| Approvals | CE, UL, TUV, FM |
NAMUR Input Signal Characteristics
The 10106/2/1 evaluates field input currents according to DIN 19234 (NAMUR). The specified switching level ranges from 1.4 to 1.9 mA, while the hysteresis is 0.2 mA +/- 0.05 mA. These values define the input switching characteristics.
Field wiring resistance must not exceed 50 Ohm. Therefore, installation personnel should check cable resistance and verify the connected field device's electrical compatibility before commissioning.
The module specifies an output voltage of 7.9 to 8.7 V and an output current of 170 mA. Confirm the intended circuit configuration and electrical ratings against the manufacturer's technical documentation before connecting field devices.
Frequently Asked Questions (FAQ)
Q: How many input channels does the Honeywell 10106/2/1 support?
A: The module provides 16 digital input channels using DIN 19234 (NAMUR) input characteristics.
Q: What are the input switching thresholds?
A: The specified switch level is 1.4 to 1.9 mA, with hysteresis of 0.2 mA +/- 0.05 mA.
Q: What power supply requirements apply to this module?
A: The specified power requirements are 5 VDC at 160 mA and 24 VDC at 110 mA. Verify that the installed system provides both required supply rails.
Field Installation Guidelines
- Verify module compatibility: Confirm the module designation, system hardware configuration, and required software version of 510 or later before installation.
- Check mounting space: Allow for the specified 4 TE and 3 HE mounting requirements, equivalent to 4 HP and 3U.
- Inspect field wiring: Verify conductor condition, terminal assignments, polarity where applicable, and field wire resistance. Keep resistance within the specified maximum of 50 Ohm.
- Confirm signal compatibility: Ensure connected field devices match the DIN 19234 (NAMUR) input characteristics and the specified switching thresholds.
- Verify power supplies: Check the 5 VDC and 24 VDC supply rails against the module requirements before energizing the system.
- Separate signal wiring: Route low-level field signal cables away from high-current and switching conductors where practical. Apply the system manufacturer's shielding and grounding instructions.
- Test input response: After installation, verify all 16 channels against known field input states and confirm correct indication within the documented operating thresholds.
- Validate safety behavior: Follow the approved system safety documentation for fail-safe testing and commissioning. Do not infer SIL capability or specific fault responses from the module designation alone.
Other Attributes
- Series: Honeywell FSC
- Country of Origin: USA
- Lead Time: In Stock, 2 Working Days
In Stock Hot Items of Honeywell
| FC-SDO-1624 | 8C-PAIH51 | MC-TAMR03 51309218-175 |
| FC-TSDI-1624 | 8C-PAIH51*E | MC-TAOY22 51204172-175 |
| FC-TSDO-1624 | 8C-PAIH52 | MU-TMCN02 561401846-200 |
| FS-TSAI-1620M | 8C-PAIN01 | MC-TAIH02 51304453-150 |
| FS-TSDI-1624 | 8C-PAOH51 | MC-TAIL02 51304437-150 |
| FC-RUSIO-3224 | 8C-PAON01 | MC-TDID72 51303928-150 |
| FC-SDI-1624 | 8C-PCNT01 | MC-TDODI3 51304650-150 |
| FC-BKM-0001 | 8C-PDIL51 | MC-TDOY23 51204166-175 |
| FC-IO-0001 | 8C-PDILAI | MU-KLAM06 51304465-400 |
| FC-PSU-UNI2450U | 8C-PDOD51 | MU-TAIH02 51304453-100 |
| FC-QPP-0001 | 8C-TAID51 | MU-TAMR03 501309218-125 |
| FC-SAI-1620M | 8C-TAIX51 | MU-TAOX12 51304335-100 |
| FC-USI-0001 | 8C-TAIX61 | MU-TDID72 51303928-100 |
| CC-PAOX01 | 8C-TAOX61 | MU-TDOD12 51304423-100 |
| CC-PFB801 | 8C-TCNT01 | MU-TDOR22 51304427-100 |
| CC-PPIX01 | TC-CCN013 | DC-TFB412 51307618-176 |
| CC-TAID11 | TC-CCR012 | TK-IOLI01 51403427-175 |
| DC-TAOX11 | TC-IAH161 | TK-PPD011 51309241-175 |
| TC-IDJ161 | TC-OAV081 | TK-PRS021 51404305-275 |
| TC-IXL061 | 10300/1/1 | CC-TAIX01 51308363-175 |
| TDCS3000LCN | 51305887-150 | 8C-PAOHA1 51454469-275 |
| TK-FPDXX2 | 10012/1/2 | 8C-PAIMA1 51454473-175 |
Our Competitive Brands
- - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
- - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
- - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
- - Bently Nevada 3300 System, 3500 System
- - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
- - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
- - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider
Question 1: Is Our Price Competitive?
NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.
Question 2: What Is The Warranty Period?
We offer a standard one-year warranty for all new and original items.
Question 3: What Payment Methods Do We Accept?
We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.
Question 4: What Shipping Methods Do We Use?
We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.
Question 5: What Is Our Delivery Time?
Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.
Question 6: How Do We Package The Goods?
Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.
Question 7: How Can Customers Contact Us And Request A Quote?
Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.