ICS Triplex T7481 Monitored Guarded Output Module
Thông số kỹ thuật
Manufacturer: ICS TRIPLEX
Condition:New with Original Package
Product Type: Digital Output Modules
-
Country of Origin: Mexico
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Bằng cách gửi yêu cầu cho mục này, bạn xác nhận rằng bạn đã xem xét và chấp nhận Điều khoản & Điều kiện của chúng tôi. Xin lưu ý rằng tất cả các giao dịch sẽ được xử lý ngoại tuyến.
Hỏi chuyên gia
Hãy giúp chúng tôi tiếp cận được nhiều người hơn! Chia sẻ sản phẩm này với mạng lưới của bạn và thể hiện sự ủng hộ của bạn!
Product Description
The ICS Triplex T7481, also cataloged as the T7481 Monitored Guarded Output Module, operates as a dedicated hardware component for 24 VDC load switching and fault supervision within the Regent + Plus safety control system. It provides sixteen monitored outputs with isolated groups, redundant switching paths, and diagnostic feedback for fail-safe execution.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | T7481 |
| Brand | ICS Triplex |
| Product Type | Monitored Guarded Output Module |
| Operating Temp | 0 to 60 deg C |
| Storage Temp | -40 to 85 deg C |
| Operating Humidity | 0 to 95% RH, non-condensing |
| Field Voltage Range | 18 to 36 VDC |
| Output Arrangement | 16 circuits in two isolated groups of 8 |
| Continuous Load Current | 2 A at 0 to 40 deg C; 1.5 A at 60 deg C |
| Minimum Load Current | 20 mA |
| Maximum On-State Voltage Drop | 1.0 V |
| Maximum Off-State Leakage | 5 mA single configuration; 7.5 mA dual configuration |
| Output Fuse Type | One 3 A, 250 V fast-acting 3AB rectifier-type fuse per output |
| Switching Delay | 0.5 ms turn-on and 0.5 ms turn-off |
| SafetyBus Power Consumption | 1.5 load units |
| Heat Dissipation | 30 W |
| Isolation Voltage | 2500 V minimum between field and logic, and between output groups |
| Power Consumption | 30 W maximum heat dissipation |
ICS Triplex Safety Control Output Monitoring
The T7481 module performs supervised switching of DC field loads through monitored guarded outputs. Each output circuit includes automatic diagnostic tests that evaluate wiring conditions, external load status, and fuse integrity. The module detects open circuits, short circuits, and output path faults through continuous monitoring functions.
For SIS architectures requiring fault tolerance, the T7481 supports operation as a single module in a fail-safe configuration or as a configured parallel pair. The dual arrangement provides additional fault tolerance while maintaining monitored output control. Individual output indicators and fault indicators provide local status information for maintenance and system diagnostics.
The module architecture follows ICS Triplex safety control principles, including galvanic isolation between field circuits and logic circuits. The isolated output groups reduce electrical interaction between channels and support separation of field load circuits.
Triple Modular Redundancy and Fail-Safe Output Execution
Within safety instrumented applications, ICS Triplex Trusted and Regent + Plus architectures use fault-tolerant design methods based on redundant processing and diagnostic coverage. The T7481 contributes to fail-safe state execution by monitoring output switching conditions and identifying abnormal field circuit behavior.
The module supports safety-related output applications where controlled DC loads require supervised activation and deactivation. Diagnostic monitoring evaluates output feedback conditions without changing the commanded field state during normal operation.
Frequently Asked Questions
Q: How many output channels does the ICS Triplex T7481 provide?
A: The T7481 provides sixteen monitored output circuits arranged as two isolated groups of eight channels.
Q: What field voltage range is supported by the T7481 output circuits?
A: The module supports a field supply range from 18 to 36 VDC for connected loads.
Q: How does the module detect external circuit faults?
A: The T7481 uses automatic diagnostic tests to detect conditions including open wiring, short circuits, and load or fuse faults.
Field Installation Guidelines
Install the T7481 module according to the Regent + Plus system hardware configuration requirements. Verify that the field wiring matches the designated output channel assignments and isolated group arrangement before energizing the module.
Use appropriate separation between field power wiring and low-level signal or communication wiring to reduce electrical interference. Confirm that output fuses, load ratings, and field voltage levels match the module specifications before commissioning.
Maintain proper cabinet grounding practices. Connect protective earth and shield layers according to the system installation standard to reduce noise coupling and improve fault detection accuracy.
Before operation, check output indicators and diagnostic status information to confirm correct module insertion, field connection status, and normal safety controller communication.
Other Attributes
- Country of Origin: Mexico
- Lead Time: In Stock, 2 Working Days
In Stock Hot Items of ICS TRIPLEX
Our Competitive Brands
- - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
- - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
- - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
- - Bently Nevada 3300 System, 3500 System
- - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
- - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
- - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider
Question 1: Is Our Price Competitive?
NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.
Question 2: What Is The Warranty Period?
We offer a standard one-year warranty for all new and original items.
Question 3: What Payment Methods Do We Accept?
We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.
Question 4: What Shipping Methods Do We Use?
We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.
Question 5: What Is Our Delivery Time?
Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.
Question 6: How Do We Package The Goods?
Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.
Question 7: How Can Customers Contact Us And Request A Quote?
Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.