Yokogawa F3AD08-5V | Analog Input Module

SKU: F3AD08-5V

Technické špecifikácie

  • Manufacturer: YOKOGAWA

  • Condition:New with Original Package

  • Product Type: Analog Input Module

  • Country of Origin: Singapore

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Odoslaním žiadosti o túto položku potvrdzujete, že ste si prečítali a prijali naše Podmienky a pravidlá. Upozorňujeme, že všetky transakcie budú spracované offline.

100% originálny a autentický
100% úplne nový, pripravený na odoslanie
Vrátenie platby za podporu, služba 7x24 hodín
1-ročná záruka na všetky produkty

Opýtajte sa odborníka

Pomôžte nám osloviť viac ľudí! Zdieľajte tento produkt so svojou sieťou a prejavte svoju podporu!

Product Description

Configured for multi-channel analog signal acquisition in Yokogawa distributed control systems, the Yokogawa F3AD08-5V (F3AD08-5V Analog Input Module) provides direct physical/electrical execution for differential voltage and current measurement within field signal acquisition layers.

HardwareSpecifications

Parameter Specification
ModelBrand Yokogawa F3AD08-5V
Weight 200 g
Dimensions 28.9 mm x 100 mm x 106.1 mm
OperatingTemp 0 to 55 degC
PowerConsumption 210 mA at 5 VDC
Input Channels 4 or 8 differential inputs (model dependent)
Input Types Voltage or Current (model dependent configuration)
Voltage Range 0-5 VDC, 1-5 VDC, -10 to 10 VDC, 0-10 VDC
Current Range 0-20 mA DC, 4-20 mA DC
ADC Resolution 12-bit
Conversion Cycle 1 ms x number of inputs
Input Resistance 1 M ohm min (voltage), 250 ohm (current)
Isolation Method Photocoupler isolation (input to internal circuit)
Withstanding Voltage 500 VDC for 1 minute
Overall Accuracy +/-0.2 percent (23 degC), +/-0.5 percent (0-55 degC)
Scaling Range -30000 to 30000
Offset Range -5000 to 5000
Filtering First-order lag or moving average selectable
Self Diagnostics Hardware diagnostics and over-range detection

Yokogawa DCS Analog Signal Conditioning Characteristics

The Yokogawa F3AD08-5V integrates tightly with Yokogawa process control architectures by implementing channel-level signal conditioning for mixed voltage and current inputs. Input acquisition supports 4-20 mA loop measurement and voltage scaling for transmitter-level field devices, enabling direct interfacing with standard instrumentation loops without external signal conversion stages.

Channel isolation is implemented through photocoupler-based separation between field inputs and internal processing circuits, reducing susceptibility to loop-induced electrical interference in multi-drop analog wiring environments. The module supports deterministic 1 ms per channel conversion sequencing, ensuring time-aligned sampling behavior across multi-input configurations in process data acquisition layers.

Scaling and offset functions are executed at module level, allowing raw ADC values to be linearized into engineering units prior to transmission to higher-level control processors.

Frequently Asked Questions

Q: Can the module process both voltage and current inputs simultaneously?
A: Input mode selection is defined per module configuration. Mixed operation depends on hardware variant and channel assignment restrictions.

Q: What is the conversion timing behavior under full channel load?
A: Conversion cycle is defined as 1 ms multiplied by number of active inputs, resulting in linear scan timing expansion with channel count.

Q: Does the module support electrical isolation between channels?
A: Input-to-internal circuit isolation is provided via photocouplers. Direct channel-to-channel isolation is not implemented.

Field Installation Guidelines

Ensure analog signal cabling is installed using shielded twisted pair conductors with single-point grounding at the control cabinet side. Maintain separation between analog input wiring and high-voltage or switching load lines to reduce induced coupling effects.

Terminal block torque for M3.5 screw connections should follow standard industrial tightening practices to maintain stable contact resistance. Avoid routing current-loop wiring in parallel with inverter output cabling over extended distances.

Verify correct configuration of voltage or current input mode prior to energizing field loops to prevent over-range input conditions.

Other Attributes

  • Country of Origin: Japan/Singapore
  • Lead Time: In Stock, 2 Working Days

 

In Stock Hot Items of YOKOGAWA

ANB10D-425/CU2N SDV144-S63 SAI143-S53
AAI143-H50/K4A00 ALE111-S50 SCP451-51
EC402-50 S1 CP471-00 SPW482-53
AAI143-H50 SCP461-51 CP461-10 S1
SAI143-H63 CP461-10 CP461-50 S2
AAI143-H50/A4S00 SAI533-H53 ACG10S-F2121 S4
ANB10D-420 SNT401-53 AIP826-2 S2
AFF50D-H41201 ADV161-P50 CP451-10
AAV144-S50 SEC402-51 CP451-11
AAI143-S53 ANB10D-420/CU2N/NDEL CP461
ANB10D-421/CU2N/NDEL SAI143-H53 CP461-50
ADV151-P53 AAI543-H53 DP97-B
PW484-50 CP451-50 YNT512D-Q12
CP345 AAI143-H53 ANB10D-410/S2
AAB841-S50 ANB10D-420 S2 NFCP100-S00
NFAF135-S50 CP461-51 CP451-10 S2
NFAI141-S00 SCP461-51 S1 SAI143-H33
NFAI141-S50 SCP461-51 S2 SAI143-H03
NFAI841-S50 SNB10D-225/CU2T CP345 S1
NFAR181-S00 AAI141-S50 SCP451-11
NFDV161-P00 AFV10D-S41211 PW702 S1
NFDV161-P50 ANB10D-421 AFV30D-A41452
AAR145-S50 ANB10D-425 ALE111-S50


Our Competitive Brands

  • - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
  • - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
  • - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
  • - Bently Nevada 3300 System, 3500 System
  • - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
  • - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
  • - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider

 

TEL: +86 18030205725     E-MAIL: manskiwong@cambia.cn

Question 1: Is Our Price Competitive?

NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.

Question 2: What Is The Warranty Period?

We offer a standard one-year warranty for all new and original items.

Question 3: What Payment Methods Do We Accept?

We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.

Question 4: What Shipping Methods Do We Use?

We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.

Question 5: What Is Our Delivery Time?

Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.

Question 6: How Do We Package The Goods?

Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.

Question 7: How Can Customers Contact Us And Request A Quote?

Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.