Honeywell TC-IDK161 16-Channel AC Digital Input Module
Technické špecifikácie
Manufacturer: Honeywell
Condition:New with Original Package
Product Type: AC Digital Input Modules
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Odoslaním žiadosti o túto položku potvrdzujete, že ste si prečítali a prijali naše Podmienky a pravidlá. Upozorňujeme, že všetky transakcie budú spracované offline.
Opýtajte sa odborníka
Pomôžte nám osloviť viac ľudí! Zdieľajte tento produkt so svojou sieťou a prejavte svoju podporu!
Product Description
The Honeywell TC-IDK161 is a 16-channel AC digital input module designed to monitor discrete field signals in industrial control systems. It accepts nominal 120 VAC inputs, with individually isolated channels for signal separation. The module provides programmable input delays, defined switching thresholds, and a 36-position terminal block connection using the TC-TBCH terminal block.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | TC-IDK161 |
| Brand | Honeywell |
| Product Type | AC Digital Input Module |
| Number of Input Channels | 16 |
| Channel Isolation | Individually isolated |
| Nominal Input Voltage | 120 VAC |
| On-State Voltage Range | 79-132 VAC |
| Input Frequency | 47-63 Hz |
| Maximum Off-State Voltage | 20 V |
| Minimum On-State Current | 5 mA at 79 V; 15 mA at 132 V |
| Maximum Off-State Current | 2.5 mA |
| Input Impedance | 11 kOhm at 60 Hz |
| Input Compatibility | IEC Type 1+ |
| Short/Inrush Current | 250 mA peak |
| Inrush Current Decay | Below 37% within 22 ms without activation |
| Programmable Off-to-On Delay | 1-10 ms |
| Programmable On-to-Off Delay | 9-18 ms |
| Hardware Delay | Up to 10 ms off-to-on; 8 ms on-to-off, plus filter time |
| Power Dissipation | 4.9 W |
| Backplane Current at 24 VDC | 0.003 A |
| Backplane Current at 5 VDC | 0.125 A |
| Terminal Block | 36-position, TC-TBCH |
| Dimensions | 51 x 178 x 356 mm |
| Weight | 0.43 lb |
Input Signal Characteristics
The TC-IDK161 monitors AC discrete signals within the specified voltage and frequency range. Its 79-132 VAC on-state range defines the voltage conditions for recognizing an active input, while the maximum off-state voltage of 20 V defines the specified inactive-state limit. The input current thresholds and impedance provide additional criteria for evaluating field signal compatibility.
The module supports IEC Type 1+ input compatibility. Its specified short-duration inrush response helps distinguish transient current behavior from a valid input activation, provided the current decays within the stated conditions.
Input Timing and Isolation
Programmable input delays allow the recognition timing to be adjusted for different signal transition requirements. The off-to-on and on-to-off delays have separate adjustment ranges, so signal activation and deactivation can be evaluated independently. Hardware delay and filter time also affect the overall response.
The specified 2546 VDC isolation rating applies to channel-to-channel and user-to-system isolation during a 1-second test. This rating describes the stated test condition and should not be interpreted as a continuous operating voltage rating.
Connection and Power Requirements
The module uses a 36-position TC-TBCH terminal block for field connections. Confirm the terminal assignment and wiring arrangement before connecting field devices, as the supplied specifications do not identify individual terminal positions.
Power planning should account for the listed backplane current draws at 5 VDC and 24 VDC, as well as the module's 4.9 W power dissipation. These values describe different electrical parameters and should not be treated as interchangeable.
Frequently Asked Questions
Q: What input signals does the Honeywell TC-IDK161 accept?
A: It accepts AC digital input signals with a nominal voltage of 120 VAC. The specified on-state range is 79-132 VAC at 47-63 Hz.
Q: Which terminal block is specified for the TC-IDK161?
A: The specified connection is a 36-position TC-TBCH terminal block. Verify the terminal assignment against the applicable wiring documentation before installation.
Q: Can the input response time be adjusted?
A: Yes. The specified programmable off-to-on delay is 1-10 ms, and the on-to-off delay is 9-18 ms. Hardware delay and filter time also contribute to the overall input response.
Other Attributes
- Series: Honeywell Experion PKS(C200,C300)
- Country of Origin: USA
- Lead Time: In Stock, 2 Working Days
In Stock Hot Items of Honeywell
| FC-SDO-1624 | 8C-PAIH51 | MC-TAMR03 51309218-175 |
| FC-TSDI-1624 | 8C-PAIH51*E | MC-TAOY22 51204172-175 |
| FC-TSDO-1624 | 8C-PAIH52 | MU-TMCN02 561401846-200 |
| FS-TSAI-1620M | 8C-PAIN01 | MC-TAIH02 51304453-150 |
| FS-TSDI-1624 | 8C-PAOH51 | MC-TAIL02 51304437-150 |
| FC-RUSIO-3224 | 8C-PAON01 | MC-TDID72 51303928-150 |
| FC-SDI-1624 | 8C-PCNT01 | MC-TDODI3 51304650-150 |
| FC-BKM-0001 | 8C-PDIL51 | MC-TDOY23 51204166-175 |
| FC-IO-0001 | 8C-PDILAI | MU-KLAM06 51304465-400 |
| FC-PSU-UNI2450U | 8C-PDOD51 | MU-TAIH02 51304453-100 |
| FC-QPP-0001 | 8C-TAID51 | MU-TAMR03 501309218-125 |
| FC-SAI-1620M | 8C-TAIX51 | MU-TAOX12 51304335-100 |
| FC-USI-0001 | 8C-TAIX61 | MU-TDID72 51303928-100 |
| CC-PAOX01 | 8C-TAOX61 | MU-TDOD12 51304423-100 |
| CC-PFB801 | 8C-TCNT01 | MU-TDOR22 51304427-100 |
| CC-PPIX01 | TC-CCN013 | DC-TFB412 51307618-176 |
| CC-TAID11 | TC-CCR012 | TK-IOLI01 51403427-175 |
| DC-TAOX11 | TC-IAH161 | TK-PPD011 51309241-175 |
| TC-IDJ161 | TC-OAV081 | TK-PRS021 51404305-275 |
| TC-IXL061 | 10300/1/1 | CC-TAIX01 51308363-175 |
| TDCS3000LCN | 51305887-150 | 8C-PAOHA1 51454469-275 |
| TK-FPDXX2 | 10012/1/2 | 8C-PAIMA1 51454473-175 |
Our Competitive Brands
- - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
- - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
- - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
- - Bently Nevada 3300 System, 3500 System
- - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
- - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
- - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider
Question 1: Is Our Price Competitive?
NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.
Question 2: What Is The Warranty Period?
We offer a standard one-year warranty for all new and original items.
Question 3: What Payment Methods Do We Accept?
We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.
Question 4: What Shipping Methods Do We Use?
We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.
Question 5: What Is Our Delivery Time?
Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.
Question 6: How Do We Package The Goods?
Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.
Question 7: How Can Customers Contact Us And Request A Quote?
Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.