Honeywell MU-TMCN02 FTA Mounting Channel
Technické špecifikácie
Manufacturer: Honeywell
Condition:New with Original Package
Product Type: Gas Detection Transmitters
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Odoslaním žiadosti o túto položku potvrdzujete, že ste si prečítali a prijali naše Podmienky a pravidlá. Upozorňujeme, že všetky transakcie budú spracované offline.
Opýtajte sa odborníka
Pomôžte nám osloviť viac ľudí! Zdieľajte tento produkt so svojou sieťou a prejavte svoju podporu!
Product Description
Configured for physical termination hardware mounting in Honeywell control system assemblies, the Honeywell MU-TMCN02 (MU-TMCN02 FTA Mounting Channel) provides a structured mechanical base for FTA and terminal hardware. The component supports organized field wiring and physical installation within compatible Honeywell control architectures.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | MU-TMCN02 |
| Part Number | 561401846-200 |
| Brand | Honeywell |
| Product Type | FTA Mounting Channel / Terminal Assembly Component |
| Origin | USA |
| Operating Temp | 0 deg C to +60 deg C |
| Storage Temp | -40 deg C to +85 deg C |
| Relative Humidity | 5% to 95% RH, non-condensing |
| Power Consumption | Not specified |
| System Compatibility | Honeywell Experion PKS and related control system architectures |
| Mounting | DIN rail or panel mounting, as specified for the installation |
| Primary Function | Mechanical mounting and physical organization of FTA and terminal hardware |
Honeywell DCS Termination and Mounting Characteristics
The MU-TMCN02 provides a physical mounting interface for field termination hardware. Therefore, installation should maintain the specified mechanical alignment between the mounting channel, terminal components, and associated wiring.
The supplied information does not specify an electrical signal interface, communication protocol, channel isolation rating, or power requirement for the MU-TMCN02. Consequently, these characteristics should not be assigned to the mounting component without the applicable Honeywell installation documentation.
The component can support organized termination assemblies within compatible Honeywell architectures. Field wiring should remain separated from power conductors and should follow the cabinet grounding and shielding practices defined for the associated FTA.
Frequently Asked Questions
Q: Does the MU-TMCN02 itself provide an I/O signal interface?
A: The supplied specifications identify it as an FTA mounting channel / terminal assembly component. They do not specify an independent I/O signal interface.
Q: Does the MU-TMCN02 consume electrical power?
A: No power-consumption value is specified in the supplied data. It should therefore be treated as a mounting component rather than assigned an electrical load without supporting documentation.
Q: What environmental limits are specified for the component?
A: The supplied data specifies 0 deg C to +60 deg C operating temperature, -40 deg C to +85 deg C storage temperature, and 5% to 95% RH non-condensing.
Field Installation Guidelines
Install the MU-TMCN02 on the designated DIN rail or panel mounting structure and verify that the mounting surface remains mechanically secure.
Position associated FTA and terminal hardware according to the applicable Honeywell cabinet layout. Keep field wiring organized and prevent excessive mechanical force from transferring to terminal connections.
Route signal wiring separately from high-voltage and high-current conductors where the cabinet design permits. Maintain appropriate cable bend radius and avoid sharp edges or excessive cable tension.
Connect cable shields and protective conductors according to the grounding scheme specified for the associated Honeywell control system. Do not create unintended ground loops by applying additional shield connections without system documentation.
Before commissioning, inspect mounting hardware, terminal alignment, conductor identification, and cable routing. Verify all associated electrical connections against the approved system drawings.
Other Attributes
- Series: Honeywell Experion PKS(C200,C300)
- Country of Origin: USA
- Lead Time: In Stock, 2 Working Days
In Stock Hot Items of Honeywell
| FC-SDO-1624 | 8C-PAIH51 | MC-TAMR03 51309218-175 |
| FC-TSDI-1624 | 8C-PAIH51*E | MC-TAOY22 51204172-175 |
| FC-TSDO-1624 | 8C-PAIH52 | MU-TMCN02 561401846-200 |
| FS-TSAI-1620M | 8C-PAIN01 | MC-TAIH02 51304453-150 |
| FS-TSDI-1624 | 8C-PAOH51 | MC-TAIL02 51304437-150 |
| FC-RUSIO-3224 | 8C-PAON01 | MC-TDID72 51303928-150 |
| FC-SDI-1624 | 8C-PCNT01 | MC-TDODI3 51304650-150 |
| FC-BKM-0001 | 8C-PDIL51 | MC-TDOY23 51204166-175 |
| FC-IO-0001 | 8C-PDILAI | MU-KLAM06 51304465-400 |
| FC-PSU-UNI2450U | 8C-PDOD51 | MU-TAIH02 51304453-100 |
| FC-QPP-0001 | 8C-TAID51 | MU-TAMR03 501309218-125 |
| FC-SAI-1620M | 8C-TAIX51 | MU-TAOX12 51304335-100 |
| FC-USI-0001 | 8C-TAIX61 | MU-TDID72 51303928-100 |
| CC-PAOX01 | 8C-TAOX61 | MU-TDOD12 51304423-100 |
| CC-PFB801 | 8C-TCNT01 | MU-TDOR22 51304427-100 |
| CC-PPIX01 | TC-CCN013 | DC-TFB412 51307618-176 |
| CC-TAID11 | TC-CCR012 | TK-IOLI01 51403427-175 |
| DC-TAOX11 | TC-IAH161 | TK-PPD011 51309241-175 |
| TC-IDJ161 | TC-OAV081 | TK-PRS021 51404305-275 |
| TC-IXL061 | 10300/1/1 | CC-TAIX01 51308363-175 |
| TDCS3000LCN | 51305887-150 | 8C-PAOHA1 51454469-275 |
| TK-FPDXX2 | 10012/1/2 | 8C-PAIMA1 51454473-175 |
Our Competitive Brands
- - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
- - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
- - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
- - Bently Nevada 3300 System, 3500 System
- - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
- - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
- - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider
Question 1: Is Our Price Competitive?
NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.
Question 2: What Is The Warranty Period?
We offer a standard one-year warranty for all new and original items.
Question 3: What Payment Methods Do We Accept?
We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.
Question 4: What Shipping Methods Do We Use?
We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.
Question 5: What Is Our Delivery Time?
Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.
Question 6: How Do We Package The Goods?
Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.
Question 7: How Can Customers Contact Us And Request A Quote?
Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.