Bachmann CNT204 Counter Module
Especificações técnicas
Manufacturer: Bachmann
Condition:New with Original Package
Product Type: Counter Modules
-
Country of Origin: Austria
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Ao enviar um pedido para este item, você confirma que revisou e aceitou nossos Termos & Condições. Por favor, note que todas as transações serão processadas offline.
Pergunte a um especialista
Ajude-nos a alcançar mais pessoas! Compartilhe este produto com sua rede e mostre seu apoio!
Product Description
The Bachmann CNT204 is a counter module designed to process pulse signals from single-line pulse generators and incremental encoders. It provides four counter inputs, with two channels available for incremental encoder operation. The module supports 32-bit counting, configurable signal evaluation, encoder power supply, and high-resolution time measurements for monitoring pulse timing and phase differences.
Key Features
- Four counter inputs for single-line pulse generators.
- Two channels configurable for incremental encoder signals.
- 32-bit counter resolution.
- Incremental encoder evaluation with 1-fold, 2-fold, or 4-fold edge evaluation, or pulse direction mode.
- Adjustable input filters for signal conditioning.
- Green LED status indication for each counter or initiator input.
- Encoder power supply directly from the module via the terminal block.
- Synchronization of inputs.
- Monitoring of all supply voltages.
- Period and differential measurements with 42 ns resolution.
- Reverse polarity protection for the external power supply.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | CNT204 |
| Brand | Bachmann |
| Product Type | Counter Module |
| Number of Incremental Encoder Channels | 2 |
| Encoder Counter Resolution | 32 bit |
| Encoder Input Signals | A-, A+, B-, B+, N-, N+ |
| Encoder Signal Evaluation | 1-fold, 2-fold, 4-fold edge evaluation or pulse direction mode |
| Maximum Encoder Input Frequency | 1 MHz (RS-422) / 300 kHz (HTL) |
| Encoder Input Filter | 185 kHz to 6 MHz adjustable; default 6 MHz |
| Number of Counter Inputs | 4, reduced to 2 when incremental encoder inputs are used |
| Counter Resolution | 32 bit |
| Maximum Counter Input Frequency | 20 kHz |
| Minimum Pulse Length | 25 us |
| Counter Input Filter | 183 Hz to 46.88 kHz adjustable; disabled by default (fg = 100 kHz) |
| Period Measurement Resolution | 42 ns |
| Differential Measurement Resolution | 42 ns |
| Differential Measurement Channels | C1 and C3, or C2 and C4 |
| Encoder Supply Voltage | +5 V and +24 V |
| +5 V Supply Output | Uext - 1 V |
| +5 V Supply Tolerance | +/- 5% |
| +5 V Maximum Current per Encoder | 200 mA |
| +24 V Supply Output | Same as Uext |
| +24 V Maximum Current per Encoder | 300 mA |
| +5 V Residual Ripple | Less than 150 mV peak-to-peak |
| +24 V Residual Ripple | Same as Uext |
| Encoder Supply Short-Circuit Protection | Yes, permanent |
| External Power Supply | 18 VDC to 34 VDC |
| Current Consumption | 40 mA at 24 VDC + 1.2 x encoder current consumption |
| Reverse Polarity Protection | Yes |
| General Approvals | CE, UKCA, cULus |
| Marine Approvals | ABS, BV, DNV, KR, LR, NK, RINA |
| Operating Temperature | -30 deg C to +60 deg C |
| ColdClimate Operating Temperature | -30 deg C to +60 deg C |
| Operating Relative Humidity | Standard: 5% to 95%, noncondensing; ColdClimate: 5% to 95%, with condensation |
| Storage Temperature | -40 deg C to +85 deg C |
| Storage Relative Humidity | 5% to 95%, with condensation |
| Pollution Degree | 2 (IEC 60664-1) |
Counter and Encoder Operation
The CNT204 handles pulse counting and incremental encoder signals through configurable input channels. When incremental encoders are used, the module evaluates the A, B, and N signals according to the selected edge evaluation or pulse direction mode. This allows the application to process encoder pulse sequences and associated timing information.
The four counter inputs support single-line pulse generators with a maximum input frequency of 20 kHz. Using the two incremental encoder channels reduces the number of available counter inputs to two, so the required channel configuration should be checked before selection.
Measurement and Signal Monitoring
The module measures signal periods with a resolution of 42 ns. It can also measure the phase shift between counter inputs C1 and C3 or between C2 and C4 at the same resolution. These functions provide timing information for applications that require pulse interval or phase comparison.
Adjustable input filters allow the signal conditioning to be configured for the relevant input type. The module also monitors supply voltages and provides green LED status indication for each counter or initiator input.
Power Supply and Environmental Conditions
The CNT204 requires an external supply of 18 VDC to 34 VDC. Its encoder supply outputs provide +5 V and +24 V directly through the terminal block, subject to the specified voltage and current limits. The stated current consumption includes a base load of 40 mA at 24 VDC plus 1.2 times the encoder current consumption.
The module has a standard operating temperature range of -30 deg C to +60 deg C. The ColdClimate version has a different humidity condition, allowing operation at 5% to 95% relative humidity with condensation. Confirm the exact hardware variant before applying the relevant environmental specifications.
Frequently Asked Questions
Q: How many counter inputs are available on the CNT204?
A: The module provides four counter inputs for single-line pulse generators. When the two incremental encoder channels are used, the number of available counter inputs is reduced to two.
Q: What incremental encoder signals does the CNT204 support?
A: The listed signals are A-, A+, B-, B+, N-, and N+. The module supports 1-fold, 2-fold, or 4-fold edge evaluation and pulse direction mode. The maximum stated input frequency is 1 MHz for RS-422 or 300 kHz for HTL.
Q: What power supply does the CNT204 require?
A: The external supply range is 18 VDC to 34 VDC. The module can also supply encoders at +5 V and +24 V through its terminal block, within the specified current limits per encoder.
Other Attributes
- Country of Origin: Austria
- Lead Time: In Stock, 2 Working Days
In Stock Hot Items of Bachmann
| WT205V | AIO288 | FM211 |
| BS208 | PCC200 | DIO248 |
| GIO212 | CM202 | BS206 |
| MX220 | ACR222/2 | DIO216 |
| MPC240/W | ISI222 | PTAI216 |
| NT250 | MPC270 | MPC240 |
| SWI205 | AI204/2 | 00016586-00 |
Our Competitive Brands
- - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
- - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
- - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
- - Bently Nevada 3300 System, 3500 System
- - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
- - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
- - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider
Question 1: Is Our Price Competitive?
NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.
Question 2: What Is The Warranty Period?
We offer a standard one-year warranty for all new and original items.
Question 3: What Payment Methods Do We Accept?
We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.
Question 4: What Shipping Methods Do We Use?
We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.
Question 5: What Is Our Delivery Time?
Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.
Question 6: How Do We Package The Goods?
Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.
Question 7: How Can Customers Contact Us And Request A Quote?
Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.