Emerson VE4017 FOUNDATION Fieldbus H1 Interface Card
Specyfikacja techniczna
Manufacturer: Emerson
Condition:New with Original Package
Product Type: FOUNDATION Fieldbus Interface Cards
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Składając prośbę o ten przedmiot, potwierdzasz, że zapoznałeś się i zaakceptowałeś nasze Warunki korzystania. Proszę pamiętać, że wszystkie transakcje będą przetwarzane offline.
Zapytaj eksperta
Pomóż nam dotrzeć do większej liczby osób! Udostępnij ten produkt swojej sieci i okaż swoje wsparcie!
Product Description
Configured for FOUNDATION Fieldbus H1 communication in the Emerson DeltaV M-series DCS, the Emerson VE4017P0 (VE4017 FOUNDATION Fieldbus H1 Interface Card) provides two independent communication ports for exchanging digital process data with field instruments.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | VE4017P0 |
| Base Model | VE4017 |
| Brand | Emerson |
| Product Series | DeltaV M-series |
| Product Type | FOUNDATION Fieldbus H1 Interface Card |
| Operating Temp | -40 to 70 deg C (provided data) |
| Storage Temperature | -40 to 85 deg C |
| Relative Humidity | 5% to 95%, non-condensing |
| Power Consumption | Maximum 200 mA at nominal 12 VDC LocalBus supply |
| Communication Ports | 2 FOUNDATION Fieldbus H1 ports |
| Field Devices per Port | Up to 16, subject to fieldbus segment power and device requirements |
| Field Circuit Voltage | 9 to 32 VDC |
| Field Circuit Current | 12 mA per channel, as provided |
| Function Block Capacity | Up to 96 per card, as provided |
| Isolation | Channel-to-system and channel-to-channel isolation, as provided |
| Isolation Test Voltage | 1,500 VDC, as provided |
| Enclosure Protection | IP20 |
| Protocol | FOUNDATION Fieldbus H1 |
FOUNDATION Fieldbus H1 Communication and Isolation
The VE4017 interface supports two FOUNDATION Fieldbus H1 ports for digital communication with compatible field instruments. Each port can accommodate up to 16 devices, subject to segment power availability, device current requirements, and network design constraints.
Channel-to-system and channel-to-channel isolation separates communication circuits from the system interface and other channels. Verify the applicable hardware revision documentation for isolation ratings, grounding arrangements, and approved segment configurations before installation.
The supplied information lists a function block capacity of up to 96 per card, comprising 64 fieldbus and 32 standard DeltaV function blocks. Confirm this capacity against the installed hardware revision and DeltaV software documentation.
Frequently Asked Questions
Q: How many FOUNDATION Fieldbus H1 ports does the VE4017P0 provide?
A: The supplied specifications identify two independent FOUNDATION Fieldbus H1 communication ports.
Q: What field supply voltage does the interface support?
A: The supplied data specifies a field circuit voltage range of 9 to 32 VDC. Confirm the segment power requirements and device load before connecting field instruments.
Q: What is the LocalBus current consumption?
A: The supplied data specifies a maximum LocalBus current consumption of 200 mA at a nominal 12 VDC supply. Check the DeltaV carrier loading documentation to verify the available current budget.
Field Installation Guidelines
- Verify the VE4017P0 model and hardware revision against the DeltaV system configuration before installation.
- Confirm carrier compatibility and available LocalBus current capacity before inserting the interface card.
- Separate FOUNDATION Fieldbus H1 wiring from high-voltage power cables and other sources of electrical interference.
- Follow the approved fieldbus segment wiring, shield termination, grounding, and termination requirements.
- Check field segment voltage, device current consumption, and total segment loading before connecting instruments.
- Verify channel isolation requirements and protective grounding arrangements against the manufacturer's installation documentation.
- Confirm configuration recognition and communication status through the DeltaV engineering tools after installation.
- Do not assume hot-swap support or redundant operation without confirming the applicable hardware and system documentation.
Other Attributes
- Country of Origin: USA
- Lead Time: In Stock, 2 Working Days
In Stock Hot Items of Emerson DeltaV
| KC3010X1-BAI | KJ2201X1-HA1 | KJ3221X1-EA1 |
| KC4011X1-BP1 | KJ3242X1-FA1 | KJ1501X1-BC1 |
| KJ1501X1-BA2 | KJ4001X1-CJ1 | KJ3102X1-BA1 |
| KJ3001X1-BB1 | KJ3221X1-BA1 | KJ2005X1-MQ1 |
| KJ3001X1-BE1 | KJ3002X1-BF1 | KJ1501X1-BA1 |
| KJ3001X1-BG1 | KJ3208X1-BA2 | KJ1501X1-BB1 |
| KJ3001X1-BJ1 | KJ3242X1-EA1 | KJ2002X1-BA1 |
| KJ3002X1-BC1 | KJ4001X1-BE1 | KJ3002X1-BB1 |
| KJ3002X1-BE1 | KJ3223X1-BA1 | KJ3002X1-BG1 |
| KJ3201X1-EA1 | KJ4001X1-NB1 | KJ3004X1-BA1 |
| KJ3222X1-EA1 | KJ4001X1-NA1 | KJ3242X1-BA1 |
| KJ4001X1-CE1 | KJ2003X1-BB1 | KC3011X1-BA1 |
| KJ2201X1-BA1 | KJ3002X1-BG2 | KL4201X1-BA1 |
| KJ2005X1-BA1 | KJ3201X1-BA1 | KJ4001X1-BA3 |
| KJ2003X1-BA2 | KJ3202X1-BA1 | CL6721X1-A4 41B5215X132 |
| KJ3204X1-BA1 | KJ3206X1-BA1 | CL6821X1-A5 43B5797X032 |
| KJ4001X1-CB1 | KJ3208X1-BA1 | CL6821X1-A6 12P0663X032 |
| KJ4001X1-HB1 | KJ3222X1-BA1 | CL6824X1-A1 12P0050X032 |
| KJ4001X1-CH1 | KJ3241X1-BA1 | CL6824X1-A2 12P0050X052 |
| KJ3004X1-EA1 | KJ4001X1-CA1 | CL6824X1-A6 12P0767X032 |
| KJ3243X1-BA1 | KJ4001X1-CC1 | DC9430X1-CA1 34B2574X012 |
| KJ3203X1-BA1 | KJ1501X1-BC2 | KJ3221X1-BK1 12P4704X042 |
| KJ4001X1-CG1 | KJ4001X1-BA2 | KJ4001X1-BE1 12P0818X072 |
Our Competitive Brands
- - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
- - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
- - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
- - Bently Nevada 3300 System, 3500 System
- - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
- - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
- - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider
Question 1: Is Our Price Competitive?
NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.
Question 2: What Is The Warranty Period?
We offer a standard one-year warranty for all new and original items.
Question 3: What Payment Methods Do We Accept?
We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.
Question 4: What Shipping Methods Do We Use?
We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.
Question 5: What Is Our Delivery Time?
Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.
Question 6: How Do We Package The Goods?
Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.
Question 7: How Can Customers Contact Us And Request A Quote?
Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.