CC-TAOX01 51308351-175 | Output IOTA Board | Honeywell
Tehniskās specifikācijas
Manufacturer: Honeywell
Condition:New with Original Package
Product Type: Output IOTA Board
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Iesniedzot pieprasījumu par šo preci, jūs apstiprināt, ka esat izskatījis un pieņēmis mūsu Noteikumus un nosacījumus. Lūdzu, ņemiet vērā, ka visas transakcijas tiks apstrādātas bezsaistē.
Jautājiet ekspertam
Palīdziet mums sasniegt vairāk cilvēku! Kopīgojiet šo produktu ar savu tīklu un izrādiet savu atbalstu!
Product Description
Configured for analog current output execution in a Honeywell control system, the Honeywell CC-TAOX01 51308351-175 (CC-TAOX01 Output IOTA Board) provides direct electrical interface for 4-20 mA analog output channels. The module supports non-redundant operation with 24 VDC field wiring and calibrated current transmission for external control devices.
Suffix Breakdown & Model Matrix
The supplied documentation identifies a single catalog number only. No official suffix allocation or option matrix is specified. Therefore, no model suffix interpretation is provided.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | CC-TAOX01 51308351-175 |
| Brand | Honeywell |
| Description | Output IOTA Board |
| Module Type | Analog Output IOTA Board |
| Origin | USA |
| Place of Shipment | Xiamen, China |
| Weight | 0.24 kg |
| Dimensions | 14.6 x 12.1 x 6.8 cm |
| Operating Temp | Up to 60 deg C |
| Power Supply | 24 VDC |
| Power Consumption | Not specified |
| Output Type | 4-20 mA analog current |
| Output Channels | 16 |
| Output Ripple | Less than 100 mV peak-to-peak across 250 ohm load at power line frequency |
| Output Temperature Drift | 0.005% of full scale per deg C |
| Output Readback Accuracy | +/-4% of full scale |
| Output Current Linearity | +/-0.05% of full scale nominal |
| Resolution | +/-0.05% of full scale |
| Calibrated Accuracy | +/-0.35% of full scale at 25 deg C including linearity |
| Directly Settable Output Range | 0 mA, 2.9 mA to 21.1 mA |
| Maximum Resistive Load | 800 ohms |
| Maximum Output Compliance Voltage | 16 V |
| Maximum Open Circuit Voltage | 22 V |
| Redundancy | Non-redundant |
| Protective Coating | Coated |
Channel-to-Channel Isolation Considerations
The CC-TAOX01 output interface is intended for independent analog current transmission on 16 output channels. Proper installation practice requires separation of analog field wiring from high-energy conductors to minimize coupled noise and preserve output accuracy. Shield termination should follow the control system grounding philosophy, and shield continuity should be maintained without creating multiple ground paths.
The module is designed for standard 4-20 mA process control loops. Loop loading must remain within the specified compliance voltage and maximum resistive load limits to maintain calibrated output performance.
Frequently Asked Questions
Q: Does this module support hot replacement while the controller remains energized?
A: The supplied specifications do not state hot-swap capability. Module replacement should follow the maintenance procedure defined for the associated Honeywell control platform.
Q: Can each output channel directly drive an 800 ohm load?
A: Yes. The specified maximum resistive load is 800 ohms, provided the output remains within the stated compliance voltage limits.
Q: Is HART communication specified for the 4-20 mA outputs?
A: The available documentation identifies standard 4-20 mA analog output characteristics only. HART protocol support is not specified.
Field Installation Guidelines
- Verify 24 VDC field power before connecting field wiring.
- Route analog output cables separately from motor power and high-current conductors.
- Use shielded twisted-pair cable where required by the installation standard.
- Terminate cable shields according to the site's grounding practice to reduce electrical noise.
- Confirm field device loop resistance does not exceed the specified 800 ohm maximum load.
- Inspect terminal connections for correct polarity before energizing the output circuits.
- Replace or install the module only in accordance with the maintenance procedure for the associated control system.
Other Attributes
- Series: Honeywell Experion PKS(C200,C300)
- Country of Origin: USA
- Lead Time: In Stock, 2 Working Days
In Stock Hot Items of Honeywell
| FC-SDO-1624 | 8C-PAIH51 | MC-TAMR03 51309218-175 |
| FC-TSDI-1624 | 8C-PAIH51*E | MC-TAOY22 51204172-175 |
| FC-TSDO-1624 | 8C-PAIH52 | MU-TMCN02 561401846-200 |
| FS-TSAI-1620M | 8C-PAIN01 | MC-TAIH02 51304453-150 |
| FS-TSDI-1624 | 8C-PAOH51 | MC-TAIL02 51304437-150 |
| FC-RUSIO-3224 | 8C-PAON01 | MC-TDID72 51303928-150 |
| FC-SDI-1624 | 8C-PCNT01 | MC-TDODI3 51304650-150 |
| FC-BKM-0001 | 8C-PDIL51 | MC-TDOY23 51204166-175 |
| FC-IO-0001 | 8C-PDILAI | MU-KLAM06 51304465-400 |
| FC-PSU-UNI2450U | 8C-PDOD51 | MU-TAIH02 51304453-100 |
| FC-QPP-0001 | 8C-TAID51 | MU-TAMR03 501309218-125 |
| FC-SAI-1620M | 8C-TAIX51 | MU-TAOX12 51304335-100 |
| FC-USI-0001 | 8C-TAIX61 | MU-TDID72 51303928-100 |
| CC-PAOX01 | 8C-TAOX61 | MU-TDOD12 51304423-100 |
| CC-PFB801 | 8C-TCNT01 | MU-TDOR22 51304427-100 |
| CC-PPIX01 | TC-CCN013 | DC-TFB412 51307618-176 |
| CC-TAID11 | TC-CCR012 | TK-IOLI01 51403427-175 |
| DC-TAOX11 | TC-IAH161 | TK-PPD011 51309241-175 |
| TC-IDJ161 | TC-OAV081 | TK-PRS021 51404305-275 |
| TC-IXL061 | 10300/1/1 | CC-TAIX01 51308363-175 |
| TDCS3000LCN | 51305887-150 | 8C-PAOHA1 51454469-275 |
| TK-FPDXX2 | 10012/1/2 | 8C-PAIMA1 51454473-175 |
Our Competitive Brands
- - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
- - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
- - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
- - Bently Nevada 3300 System, 3500 System
- - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
- - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
- - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider
Question 1: Is Our Price Competitive?
NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.
Question 2: What Is The Warranty Period?
We offer a standard one-year warranty for all new and original items.
Question 3: What Payment Methods Do We Accept?
We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.
Question 4: What Shipping Methods Do We Use?
We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.
Question 5: What Is Our Delivery Time?
Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.
Question 6: How Do We Package The Goods?
Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.
Question 7: How Can Customers Contact Us And Request A Quote?
Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.