The GE IS200EACFG1BAA, based on the IS200EACF Exciter AC Feedback Board designation, measures three-phase AC voltage from the exciter Power Potential Transformer (PPT) and receives current signals from two flux or air-core current sensors. It belongs to the GE EX2100 excitation control system and provides conditioned measurement signals to the M1, M2, and C controller interfaces.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | IS200EACFG1BAA |
| Brand | General Electric (GE) |
| Series | EX2100 |
| Product Type | Exciter AC Feedback Board |
| Functional Category | AC Voltage and Current Measurement |
| Origin | United States of America (USA) |
| Operating Temp | -30 to 65 deg C |
| Voltage Measurement | Three-phase AC voltage |
| Voltage Rating | Up to 480 V RMS for EACFG1; verify the exact rating for the supplied assembly |
| Current Measurement | Two flux or air-core current sensor inputs |
| Voltage Sensing Components | Input transformers T1 through T4, as identified in the supplied documentation |
| Voltage Input Terminals | TB1, TB2, TB3 |
| Current Input Terminals | TB4 |
| Controller Interfaces | Three 9-pin D-sub connectors: J504, J509, J514 |
| Backplane Interface | EBKP backplane board |
| Maximum Cable Length | Up to 90 m between EACF and EBKP, as specified in the supplied information |
| Availability | In Stock |
EX2100 AC Feedback and Signal Conditioning
The EACF board provides voltage and current measurement interfaces for the excitation system. Its voltage input transformers provide electrical isolation and reduce the input voltage for internal measurement circuits. Two flux or air-core sensor connections receive exciter current signals for conditioning and transmission to the controller interfaces.
The three D-sub connectors J504, J509, and J514 provide connections associated with the M1, M2, and C controller paths through the EBKP backplane architecture. Confirm the applicable cable assembly and connector mapping against the system drawings before wiring.
The supplied documentation identifies two EACF voltage-rating variants:
- EACFG1: Input voltage up to 480 V RMS.
- EACFG2: Input voltage up to 1000 V RMS.
These ratings describe the stated variant options. Do not assume the 1000 V RMS rating applies to the IS200EACFG1BAA assembly without confirming its hardware identification.
Frequently Asked Questions
Q: What electrical signals does the IS200EACFG1BAA measure?
A: It measures three-phase AC voltage from the exciter PPT and accepts current signals from two flux or air-core current sensors.
Q: Which connectors interface with the EX2100 controller system?
A: The board uses three 9-pin D-sub connectors identified as J504, J509, and J514 for connections associated with the controller paths through the EBKP backplane.
Q: Can the board be hot-swapped during operation?
A: The supplied information does not establish hot-swap support for this exact assembly. Confirm the applicable EX2100 hardware revision, isolation requirements, and maintenance procedure before removing or replacing the board.
Field Installation Guidelines
- Verify the hardware identity. Confirm the complete part number, assembly revision, and voltage-rating designation before installation.
- Isolate the circuit. Follow the site's electrical isolation and lockout procedures before disconnecting voltage or current measurement wiring.
- Check voltage inputs. Connect the three-phase PPT measurement circuits to the designated terminals according to the applicable GE wiring diagram.
- Check current sensor wiring. Verify the two flux or air-core sensor connections at TB4, including polarity and cable identification where specified.
- Route signal cables correctly. Separate measurement wiring from high-current conductors and switching-noise sources where practicable.
- Terminate cable shields correctly. Follow the system grounding diagram and use the designated shield termination points. Avoid creating unintended ground loops.
- Inspect controller connections. Verify J504, J509, and J514 connector seating and confirm the corresponding cable destinations at the EBKP backplane.
- Verify commissioning signals. Before returning the system to service, check voltage and current measurement values against approved commissioning procedures and controller diagnostics.
Other Attributes
- Series: GE Multilin 350 Feeder
- Country of Origin: USA
- Lead Time: In Stock, 2 Working Days
In Stock Hot Items of The GE General Electric Mark VI
| IS200ICBDH1ABB | IS210MACCH2AGG | IS220YAICS1AJ |
| IS220PPRAH1A | IS210AEBIH1BEA | IS220YDIAS1AK |
| IS220UCSAH1A | IS200ISBEH1ABB | IS220YDOAS1AJ |
| IS200ACLEH1BCB | IS200TBAIH1CDC | IS420ESWBH3A |
| IS200EPSMG2AED | IS210AEDBH4AGD | IS420UCSCS2A |
| IS200EROCH1ABC | IS200AEADH4ADA | IS410JPDHG1A |
| IS200ERIOH1ABC | IS200REBFH1BBA | IS200TBAIS1CED |
| IS200ERDDH1ABB | IS210AEBIH3BED | IS200TBCIS2CCD |
| IS200DSPXH1DBD | IS220PCLAH1A | IS200TRLYS1BGG |
| IS230TRLSH2B | IS420UCSCH1C | IS230TAISH2C |
| IS220PDIAH1B | IS200DSPXH1DBD/DSPXH1D | IS230TCISH6C |
Our Competitive Brands
- - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
- - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
- - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
- - Bently Nevada 3300 System, 3500 System
- - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
- - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
- - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider
Question 1: Is Our Price Competitive?
NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.
Question 2: What Is The Warranty Period?
We offer a standard one-year warranty for all new and original items.
Question 3: What Payment Methods Do We Accept?
We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.
Question 4: What Shipping Methods Do We Use?
We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.
Question 5: What Is Our Delivery Time?
Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.
Question 6: How Do We Package The Goods?
Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.
Question 7: How Can Customers Contact Us And Request A Quote?
Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.