Product Description
The BACHMANN DPM200 is a PROFIBUS DP communication module for the M200 controller system. It exchanges process data between the controller and PROFIBUS devices, supporting master, slave, and combined master/slave operation. The module provides two 9-pin D-sub connectors, 8 KB of process image memory, and communication rates up to 12 Mbaud for distributed automation applications.
Communication Functions
The DPM200 connects an M200 controller to PROFIBUS DP networks for cyclic process data exchange with compatible field devices. Depending on the configured operating mode, it can act as a DP Master, DP Slave, or combined Master/Slave. This allows the controller to exchange data with remote I/O stations and other PROFIBUS-based equipment.
The module supports transfer rates from 9.6 kbaud to 12 Mbaud. It can manage up to 32 slaves without a repeater or up to 125 slaves with a repeater, subject to the network configuration and applicable PROFIBUS limits.
Process Data and Controller Integration
The DPM200 provides shared process image memory for exchanging data between the PROFIBUS network and the controller. Its data consistency locking function helps maintain consistent process data during access, while configurable data handling supports the requirements of the control application.
The module supports a maximum of three DPM200 modules per M200 controller. Its firmware can be updated through SolutionCenter, providing a defined method for module firmware maintenance.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | DPM200 |
| Brand | BACHMANN |
| Product Type | PROFIBUS DP Master Module |
| Compatible Controller System | M200 |
| PROFIBUS Standard | V0 |
| Operating Modes | DP Master, DP Slave, Master/Slave |
| Process Image Memory | 8 KB x 16 DPM |
| Maximum Number of DPM200 Modules | 3 per M200 controller |
| Maximum Number of Slaves | 32 without repeater; 125 with repeater |
| Data Length | 732 bytes per slave |
| Transfer Rate | 9.6 kbaud to 12 Mbaud |
| Connection | 2 x 9-pin D-sub sockets |
| Electrical Isolation | Galvanic isolation between PROFIBUS interface and controller backplane |
| Data Consistency | Configurable data consistency locking |
| Firmware Update | Via SolutionCenter |
| Current Consumption | 400 mA at 5 V DC |
| Operating Temperature | -30 to +60 deg C |
| Relative Humidity | 5% to 95%, non-condensing |
| Country of Origin | Austria |
| Estimated Shipping Dimensions | 5.4 x 5.7 x 11.8 cm |
| Weight | 0.2 kg |
| HS Code | 8537101190 |
Connection and Configuration Considerations
The two 9-pin D-sub sockets provide the physical PROFIBUS connection points for network cabling. When planning a network, verify the configured operating mode, transmission rate, slave count, and process data requirements against the existing controller and fieldbus configuration.
The specified slave capacity depends on whether repeaters are used. Network design must also account for the applicable PROFIBUS topology, cable length, termination, and device configuration requirements.
Frequently Asked Questions
Q: Which controller system is the DPM200 designed for?
A: The DPM200 is specified for the BACHMANN M200 controller system. The maximum stated configuration is three DPM200 modules per controller.
Q: Can the DPM200 operate as a PROFIBUS DP Slave?
A: Yes. The module supports DP Master, DP Slave, and combined Master/Slave operation. The required mode must match the intended network architecture and configuration.
Q: How many PROFIBUS devices can the DPM200 support?
A: The stated maximum is 32 slaves without a repeater and 125 slaves with a repeater. The actual network configuration must comply with the applicable PROFIBUS requirements.
Other Attributes
- Country of Origin: Austria
- Lead Time: In Stock, 2 Working Days
In Stock Hot Items of Bachmann
| WT205V | AIO288 | FM211 |
| BS208 | PCC200 | DIO248 |
| GIO212 | CM202 | BS206 |
| MX220 | ACR222/2 | DIO216 |
| MPC240/W | ISI222 | PTAI216 |
| NT250 | MPC270 | MPC240 |
| SWI205 | AI204/2 | 00016586-00 |
Our Competitive Brands
- - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
- - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
- - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
- - Bently Nevada 3300 System, 3500 System
- - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
- - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
- - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider
Question 1: Is Our Price Competitive?
NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.
Question 2: What Is The Warranty Period?
We offer a standard one-year warranty for all new and original items.
Question 3: What Payment Methods Do We Accept?
We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.
Question 4: What Shipping Methods Do We Use?
We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.
Question 5: What Is Our Delivery Time?
Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.
Question 6: How Do We Package The Goods?
Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.
Question 7: How Can Customers Contact Us And Request A Quote?
Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.