Product Description
The Honeywell MC-TDID52, also identified as the MC-TDID52 Digital Input Field Termination Assembly (FTA), is described as a 32-channel interface for acquiring 24 VDC discrete signals from field devices within Honeywell TDC 3000 and TPS process control architectures. The supplied specifications list status monitoring, direct/reverse input logic, and event accumulation functions. Exact electrical thresholds and compatibility details require confirmation against the applicable hardware documentation.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | MC-TDID52 |
| Brand | Honeywell |
| Product Type | Digital Input Field Termination Assembly (FTA) |
| Number of Input Channels | 32, as stated in the supplied description |
| Nominal Voltage | 24 VDC |
| Input Voltage Range | 20-30 VDC, reported |
| Supported Functions | Digital status monitoring, direct/reverse logic, event counting |
| Isolation | Optical isolation reported |
| System Compatibility | TDC 3000 / TPS Process Manager architecture, reported |
Digital Input Signal Processing and Isolation
The supplied description identifies the MC-TDID52 as a digital input termination component for discrete field signals. Typical signal sources include push buttons, limit switches, and proximity switches.
- Signal acquisition: Receives discrete field status signals for processing by the associated control system.
- Input logic: Direct and reverse logic configurations are reported. Confirm the supported configuration options in the applicable system documentation.
- Event accumulation: Event counting is reported; supported counting modes and processing limits are not specified.
- Electrical isolation: Optical isolation is reported but requires verification for the exact hardware revision.
- Alarm processing: Time-deadband functionality is reported. Configuration limits and implementation details are not available in the supplied data.
The MC-TDID52 model designation alone does not establish the exact terminal arrangement, channel grouping, or compatibility with a particular controller revision.
Frequently Asked Questions (FAQ)
Q: What is the nominal operating voltage of the MC-TDID52?
A: The supplied specifications identify 24 VDC as the nominal voltage and report an input range of 20-30 VDC. Confirm the permissible field voltage and switching thresholds using the applicable hardware manual.
Q: Can the MC-TDID52 be replaced without shutting down the control system?
A: Hot-swap capability is not established by the supplied information. Before replacement, verify the system's power isolation requirements, termination arrangement, and controller configuration procedures.
Q: How should field wiring and signal grounding be handled?
A: Separate low-level signal wiring from high-current and switching-power conductors. Follow the manufacturer's terminal wiring and grounding instructions, and verify polarity and common-reference requirements before energizing the circuit.
Field Installation Guidelines
- Verify hardware identity: Check the MC-TDID52 nameplate, part number, hardware revision, and system compatibility before installation.
- Confirm electrical ratings: Verify field voltage, input thresholds, polarity, and common-reference requirements against the applicable technical manual.
- Inspect terminal assignments: Match every field conductor to the approved terminal diagram. Do not infer terminal positions from the channel count.
- Route signal cables: Keep discrete input wiring separate from high-current power cables and sources of electrical interference.
- Apply grounding practices: Terminate cable shields according to the system grounding design. Avoid unintended ground loops.
- Check system configuration: Confirm channel assignments, direct/reverse logic, and any event-counting or alarm deadband settings.
- Test before service: Verify each input state at the field terminals and confirm the corresponding status at the controller or operator interface.
Other Attributes
- Series: Honeywell Experion PKS(C200,C300)
- Country of Origin: USA
- Lead Time: In Stock, 2 Working Days
In Stock Hot Items of Honeywell
| FC-SDO-1624 | 8C-PAIH51 | MC-TAMR03 51309218-175 |
| FC-TSDI-1624 | 8C-PAIH51*E | MC-TAOY22 51204172-175 |
| FC-TSDO-1624 | 8C-PAIH52 | MU-TMCN02 561401846-200 |
| FS-TSAI-1620M | 8C-PAIN01 | MC-TAIH02 51304453-150 |
| FS-TSDI-1624 | 8C-PAOH51 | MC-TAIL02 51304437-150 |
| FC-RUSIO-3224 | 8C-PAON01 | MC-TDID72 51303928-150 |
| FC-SDI-1624 | 8C-PCNT01 | MC-TDODI3 51304650-150 |
| FC-BKM-0001 | 8C-PDIL51 | MC-TDOY23 51204166-175 |
| FC-IO-0001 | 8C-PDILAI | MU-KLAM06 51304465-400 |
| FC-PSU-UNI2450U | 8C-PDOD51 | MU-TAIH02 51304453-100 |
| FC-QPP-0001 | 8C-TAID51 | MU-TAMR03 501309218-125 |
| FC-SAI-1620M | 8C-TAIX51 | MU-TAOX12 51304335-100 |
| FC-USI-0001 | 8C-TAIX61 | MU-TDID72 51303928-100 |
| CC-PAOX01 | 8C-TAOX61 | MU-TDOD12 51304423-100 |
| CC-PFB801 | 8C-TCNT01 | MU-TDOR22 51304427-100 |
| CC-PPIX01 | TC-CCN013 | DC-TFB412 51307618-176 |
| CC-TAID11 | TC-CCR012 | TK-IOLI01 51403427-175 |
| DC-TAOX11 | TC-IAH161 | TK-PPD011 51309241-175 |
| TC-IDJ161 | TC-OAV081 | TK-PRS021 51404305-275 |
| TC-IXL061 | 10300/1/1 | CC-TAIX01 51308363-175 |
| TDCS3000LCN | 51305887-150 | 8C-PAOHA1 51454469-275 |
| TK-FPDXX2 | 10012/1/2 | 8C-PAIMA1 51454473-175 |
Our Competitive Brands
- - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
- - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
- - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
- - Bently Nevada 3300 System, 3500 System
- - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
- - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
- - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider
Question 1: Is Our Price Competitive?
NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.
Question 2: What Is The Warranty Period?
We offer a standard one-year warranty for all new and original items.
Question 3: What Payment Methods Do We Accept?
We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.
Question 4: What Shipping Methods Do We Use?
We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.
Question 5: What Is Our Delivery Time?
Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.
Question 6: How Do We Package The Goods?
Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.
Question 7: How Can Customers Contact Us And Request A Quote?
Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.