Product Description
Configured for customer and system I/O signal interfacing in the GE EX2100 excitation control system, the GE IS200ERIOH1ACB (IS200ERIOH1A Exciter Regulator Main I/O Board) provides signal interface connections between the regulator backplane and associated excitation control boards. It supports simplex and redundant configurations and interfaces with the Exciter PT/CT Terminal Board, Exciter Contact Terminal Board, Dynamic Discharge Board, and Exciter Regulator Options Card.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | IS200ERIOH1ACB |
| Base Model | IS200ERIOH1A |
| Brand | General Electric (GE) |
| Series | EX2100 |
| Product Type | Exciter Regulator Main I/O Board |
| Function | Customer and system I/O signal interfacing |
| Application | Excitation regulator control |
| Configuration | Simplex and redundant systems |
| Associated Boards | EPCT, ECTBG2, ERDD, EROC, ERRR |
| Origin | United States |
| Operating Temp | 0 to 60 deg C (provided specification) |
| Power Consumption | Not specified |
| Status Indicators | POWER LED, OK LED |
| Availability | In Stock |
EX2100 Regulator Backplane and I/O Interfaces
The IS200ERIOH1ACB provides interfaces for customer I/O signals and internal regulator system signals. Its installation location depends on the excitation system configuration.
In simplex applications, the board mounts in the Exciter Regulator Backplane (ERBP). It interfaces with customer signals associated with the Exciter PT/CT Terminal Board (EPCT) and Exciter Contact Terminal Board (ECTBG2). It also interfaces with the Exciter Regulator Dynamic Discharge Board (ERDD) and Exciter Regulator Options Card (EROC).
In redundant applications, the board is installed in the regulator backplane and the corresponding redundant regulator backplane assembly. The redundant arrangement also supports system signal interfaces associated with the Exciter Regulator Redundant Relay board (ERRR).
The board's exact channel count, electrical ratings, connector pin assignments, and signal thresholds require confirmation from the applicable GE EX2100 documentation.
Frequently Asked Questions
Q: What is the function of the IS200ERIOH1ACB in an EX2100 system?
A: It interfaces customer I/O signals and internal regulator signals with associated excitation control boards. The installation arrangement depends on whether the system uses simplex or redundant control.
Q: What do the POWER and OK LEDs indicate?
A: The POWER LED indicates the board's power status. The OK LED provides a visual indication of board operating status. LED behavior should be checked against the applicable GE troubleshooting documentation before diagnosing a fault.
Q: Can the IS200ERIOH1ACB be replaced while the excitation system is energized?
A: Hot replacement capability is not established by the supplied specifications. Confirm the system configuration, isolation requirements, and GE replacement procedure before removing or installing the board.
Field Installation Guidelines
- Verify the part number. Confirm IS200ERIOH1ACB against the installed board, equipment bill of materials, and applicable EX2100 hardware documentation.
- Confirm the mounting location. Identify the ERBP or redundant backplane position specified for the installed regulator configuration.
- Isolate the equipment. Follow the site's approved electrical isolation and lockout/tagout procedures before handling the board. Do not assume the assembly supports energized replacement.
- Inspect the hardware. Check connectors, backplane contacts, board edges, and visible components for damage or contamination.
- Check signal wiring. Verify terminal assignments and cable routing against the system drawings. Keep signal wiring separated from power conductors where required by the installation design.
- Verify grounding and shielding. Follow the GE grounding scheme and site EMC requirements. Avoid introducing unintended shield-ground connections.
- Perform functional checks. After installation, verify the POWER and OK indicators and confirm the expected I/O behavior using approved commissioning and diagnostic procedures.
Other Attributes
- Series: GE Multilin 350 Feeder
- Country of Origin: USA
- Lead Time: In Stock, 2 Working Days
In Stock Hot Items of The GE General Electric Mark VI
| IS200ICBDH1ABB | IS210MACCH2AGG | IS220YAICS1AJ |
| IS220PPRAH1A | IS210AEBIH1BEA | IS220YDIAS1AK |
| IS220UCSAH1A | IS200ISBEH1ABB | IS220YDOAS1AJ |
| IS200ACLEH1BCB | IS200TBAIH1CDC | IS420ESWBH3A |
| IS200EPSMG2AED | IS210AEDBH4AGD | IS420UCSCS2A |
| IS200EROCH1ABC | IS200AEADH4ADA | IS410JPDHG1A |
| IS200ERIOH1ABC | IS200REBFH1BBA | IS200TBAIS1CED |
| IS200ERDDH1ABB | IS210AEBIH3BED | IS200TBCIS2CCD |
| IS200DSPXH1DBD | IS220PCLAH1A | IS200TRLYS1BGG |
| IS230TRLSH2B | IS420UCSCH1C | IS230TAISH2C |
| IS220PDIAH1B | IS200DSPXH1DBD/DSPXH1D | IS230TCISH6C |
Our Competitive Brands
- - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
- - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
- - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
- - Bently Nevada 3300 System, 3500 System
- - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
- - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
- - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider
Question 1: Is Our Price Competitive?
NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.
Question 2: What Is The Warranty Period?
We offer a standard one-year warranty for all new and original items.
Question 3: What Payment Methods Do We Accept?
We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.
Question 4: What Shipping Methods Do We Use?
We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.
Question 5: What Is Our Delivery Time?
Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.
Question 6: How Do We Package The Goods?
Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.
Question 7: How Can Customers Contact Us And Request A Quote?
Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.