AAI143-S50/K4S00 Yokogawa Analog Input Module
المواصفات الفنية
Manufacturer: YOKOGAWA
Condition:New with Original Package
Product Type: Analog Input Modules
-
Country of Origin: Singapore
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
من خلال تقديم طلب للحصول على هذا العنصر، تؤكد أنك قد راجعت وقبلت الشروط والأحكام الخاصة بنا. يرجى ملاحظة أن جميع المعاملات ستتم معالجتها خارج الإنترنت.
اسأل خبيرا
ساعدونا في الوصول إلى المزيد من الناس! شارك هذا المنتج مع شبكتك وأظهر دعمك!
Product Description
The AAI143-S50/K4S00 is a Yokogawa analog input module designed to acquire 4-20 mA current signals from field transmitters. It provides 16 isolated input channels and a 10 ms data update period for process signal monitoring. Furthermore, its configurable transmitter power supply supports both 2-wire and 4-wire transmitter connections, allowing channel-level configuration to match field instrument requirements.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | AAI143-S50/K4S00 |
| Brand | Yokogawa |
| Product Type | Analog Input Module |
| Number of Input Channels | 16, isolated |
| Input Signal | 4-20 mA |
| Allowable Input Current | 24 mA |
| Withstanding Voltage | 1500 V AC for 1 minute, between input and system |
| Input Resistance (Power ON) | 270 ohm (at 20 mA) to 350 ohm (at 4 mA) |
| Input Resistance (Power OFF) | 500 kohm or larger |
| Accuracy | +/-16 uA |
| Data Update Period | 10 ms |
| Transmitter Power Supply | 19.0 V or higher at 20 mA; 25.5 V or less at 0 mA |
| Transmitter Power Supply Output Current Limit | 25 mA |
| Transmitter Configuration | 2-wire or 4-wire, selectable per channel by setting pin |
| Temperature Drift | +/-16 uA per 10 deg C |
| Maximum Current Consumption (5 VDC) | 230 mA |
| Maximum Current Consumption (24 VDC) | 540 mA |
| External Connection | Pressure clamp terminal, MIL connector cable, or dedicated KS1 cable |
| HART Communication | Available on HART-enabled configuration |
| Weight | 0.3 kg |
Input Signal and Channel Configuration
The AAI143 provides 16 isolated analog input channels for 4-20 mA field signals. Each channel measures its input independently, while the isolation between the input side and system side has a rated withstand voltage of 1500 V AC for one minute.
In addition, the module supports channel-level selection of 2-wire or 4-wire transmitter connections through setting pins. This configuration allows maintenance personnel to match the input arrangement to the connected field transmitter.
Transmitter Power Supply
The module supplies power to connected transmitters, with an output current limit of 25 mA. The specified supply voltage is at least 19.0 V at a 20 mA load and no more than 25.5 V at 0 mA.
Therefore, the transmitter supply characteristics should be checked against the connected instrument's voltage and current requirements before installation.
Ordering Configuration
The AAI143 product family includes several suffix and option configurations:
| Code | Description |
|---|---|
| -S | Standard type |
| -H | With HART digital communication |
| 5 | Without explosion protection |
| E | With explosion protection |
| 0 | Basic type |
| 3 | ISA Standard G3 option and temperature option (-20 to 70 deg C) |
| /K4A00 | KS Cable Interface Adapter for AEA4D Terminal Board, model ATK4A-00 |
| /A4S00 | Pressure Clamp Terminal Block, model ATA4S-00 |
| /A4S10 | Pressure Clamp Terminal Block with surge absorber, model ATA4S-10 |
| /A4D00 | Dual Pressure Clamp Terminal Block, model ATA4D-00 |
| /A4D10 | Dual Pressure Clamp Terminal Block with surge absorber, model ATA4D-10 |
| /CCC01 | MIL Cable Connector Cover, model ACCC01 |
Configuration note: The supplied ordering information lists /K4A00 as the KS Cable Interface Adapter option. However, the specified model is AAI143-S50/K4S00. The /K4S00 suffix does not appear in the provided option-code list, so its exact interface configuration should be confirmed before ordering.
Frequently Asked Questions
Q: How many analog input channels does the AAI143 provide?
A: It provides 16 isolated input channels. Each channel accepts a 4-20 mA current signal.
Q: Can the AAI143 connect to both 2-wire and 4-wire transmitters?
A: Yes. The module supports both transmitter types, with the selection made independently for each channel using its setting pin.
Q: Does the AAI143 support HART communication?
A: HART communication is available on the HART-enabled -H configuration. The specified -S configuration is identified as the standard type, so HART availability should not be assumed for AAI143-S50/K4S00.
Other Attributes
- Country of Origin: Japan/Singapore
- Lead Time: In Stock, 2 Working Days
In Stock Hot Items of YOKOGAWA
| ANB10D-425/CU2N | SDV144-S63 | SAI143-S53 |
| AAI143-H50/K4A00 | ALE111-S50 | SCP451-51 |
| EC402-50 S1 | CP471-00 | SPW482-53 |
| AAI143-H50 | SCP461-51 | CP461-10 S1 |
| SAI143-H63 | CP461-10 | CP461-50 S2 |
| AAI143-H50/A4S00 | SAI533-H53 | ACG10S-F2121 S4 |
| ANB10D-420 | SNT401-53 | AIP826-2 S2 |
| AFF50D-H41201 | ADV161-P50 | CP451-10 |
| AAV144-S50 | SEC402-51 | CP451-11 |
| AAI143-S53 | ANB10D-420/CU2N/NDEL | CP461 |
| ANB10D-421/CU2N/NDEL | SAI143-H53 | CP461-50 |
| ADV151-P53 | AAI543-H53 | DP97-B |
| PW484-50 | CP451-50 | YNT512D-Q12 |
| CP345 | AAI143-H53 | ANB10D-410/S2 |
| AAB841-S50 | ANB10D-420 S2 | NFCP100-S00 |
| NFAF135-S50 | CP461-51 | CP451-10 S2 |
| NFAI141-S00 | SCP461-51 S1 | SAI143-H33 |
| NFAI141-S50 | SCP461-51 S2 | SAI143-H03 |
| NFAI841-S50 | SNB10D-225/CU2T | CP345 S1 |
| NFAR181-S00 | AAI141-S50 | SCP451-11 |
| NFDV161-P00 | AFV10D-S41211 | PW702 S1 |
| NFDV161-P50 | ANB10D-421 | AFV30D-A41452 |
| AAR145-S50 | ANB10D-425 | ALE111-S50 |
Our Competitive Brands
- - ABB Advant-800xA,Advant OCS,Bailey Infi 90 and Net 90,H&B Freelance 2000,DSQC Robots,IGCT / IGBT
- - GE General Electric Field Control, Genius I/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax
- - Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,
- - Bently Nevada 3300 System, 3500 System
- - Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)
- - Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC
- - Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider
Question 1: Is Our Price Competitive?
NEW-GEN collaborates with over 50 countries worldwide. As a leading supplier in China, we can provide significant discounts to customers based on market demand.
Question 2: What Is The Warranty Period?
We offer a standard one-year warranty for all new and original items.
Question 3: What Payment Methods Do We Accept?
We accept 100% T/T (Telegraphic Transfer) before shipping. For items with a lead time, a 30% deposit is required in advance, with the remaining 70% balance due before shipping. If you have an agent in China, please contact us for RMB transfer.
Question 4: What Shipping Methods Do We Use?
We primarily utilize carriers such as FedEx, DHL, UPS, BRE, etc. If you have an account with any of these carriers, you can arrange the shipping yourself. Additionally, we offer free shipping to China freight forwarders.
Question 5: What Is Our Delivery Time?
Typically, delivery takes around 1-3 days after receiving the advance payment. For items with a quoted lead time, delivery will occur as per the specified lead time.
Question 6: How Do We Package The Goods?
Our packaging process involves multiple layers of protection. Initially, the product is placed in its original box, sealed with a label. Then, we add a layer of bubble wrap to safeguard against collisions during transportation. Finally, all products are securely packed in sturdy boxes for further protection.
Question 7: How Can Customers Contact Us And Request A Quote?
Customers can inquire via email, WhatsApp, WeChat, Skype, or any preferred communication platform. Simply reach out to us, and we'll promptly provide a quote tailored to your needs.