{"product_id":"is200ectbg3a-ge-ex2100-exciter-contact-terminal-board","title":"IS200ECTBG3A GE EX2100 Exciter Contact Terminal Board","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\" alt=\"GE\" width=\"26\" height=\"25\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IS200ECTBG3A\u003c\/strong\u003e is an Exciter Contact Terminal Board (ECTB) associated with the GE EX2100 excitation control system. It provides an interface for external digital contact inputs and relay outputs, allowing the excitation controller to monitor auxiliary equipment status and exchange contact control signals. Its described functions include generator breaker and lockout contact monitoring, together with trip and general-purpose relay interfaces.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200ECTBG3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExciter Contact Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eECTB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Description\u003c\/td\u003e\n\u003ctd\u003eExciter Contact Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Input Type\u003c\/td\u003e\n\u003ctd\u003eDigital contact inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Contact Inputs\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDedicated Contact Inputs\u003c\/td\u003e\n\u003ctd\u003e52G and 86G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Contact Outputs\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGeneral-Purpose Relay Outputs\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Configuration\u003c\/td\u003e\n\u003ctd\u003eForm-C (NO, NC, Common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Wetting Voltage\u003c\/td\u003e\n\u003ctd\u003e70 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Control Interface\u003c\/td\u003e\n\u003ctd\u003eEMIO board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Application\u003c\/td\u003e\n\u003ctd\u003eGenerator excitation control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eContact Input Monitoring\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ECTB provides six auxiliary contact input circuits for monitoring external equipment status. In addition, it handles two dedicated contact signals associated with generator protection and switching equipment: 52G for generator breaker status and 86G for generator lockout status.\u003c\/p\u003e\n\u003cp\u003eThe board uses approximately 70 VDC contact-wetting voltage to monitor external dry contacts. Meanwhile, the EMIO interface processes the contact status information for use by the excitation control system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRelay Output Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe board provides two trip contact outputs and four general-purpose relay outputs. The trip outputs interface with an external customer lockout circuit, while the EMIO board controls the general-purpose relays according to the excitation system's control logic.\u003c\/p\u003e\n\u003cp\u003eEach general-purpose Form-C relay provides three terminals:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCOM:\u003c\/strong\u003e Common terminal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNO:\u003c\/strong\u003e Normally Open contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNC:\u003c\/strong\u003e Normally Closed contact.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTherefore, external control circuits can use either the normally open or normally closed contact, depending on the required switching arrangement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEX2100 System Interface\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ECTB serves as a contact I\/O interface within the EX2100 excitation control architecture. It connects external contact circuits with the EMIO control interface, supporting contact status acquisition and relay output operation.\u003c\/p\u003e\n\u003cp\u003eFurthermore, EX2100 systems can use different control arrangements, including simplex and redundant configurations. However, ECTB board revisions may have different hardware and configuration requirements. Therefore, the control arrangement and board revision must be checked against the installed excitation system before replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the main function of the GE IS200ECTBG3A?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides contact input monitoring and relay output interfaces for the GE EX2100 excitation control system. Its described functions include auxiliary contact monitoring, generator breaker and lockout status acquisition, and external relay control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many contact inputs and relay outputs are specified?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied ECTB family information identifies six auxiliary contact inputs, two dedicated inputs (52G and 86G), two trip contact outputs, and four general-purpose Form-C relay outputs. These figures should be checked against the specific G3A board revision.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the function of the 70 VDC contact-wetting voltage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The contact-wetting voltage provides an electrical signal for monitoring external dry contacts. The control system uses changes in contact state to determine the status of connected equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the IS200ECTBG3A replace other ECTB board revisions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Interchangeability with ECTBG1 or ECTBG2 should not be assumed. The board revision, excitation control architecture, and installed system configuration must match the applicable GE documentation.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\" alt=\"GE\" width=\"26\" height=\"25\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Mark VI IS200\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003eHot Items \u003c\/span\u003eof \u003cspan\u003eThe GE Speedtronic Mark V\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"656\" height=\"276\" style=\"border-collapse: collapse; width: 492.02pt;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"222\" style=\"width: 166.50pt;\"\u003e \u003ccol width=\"215\" style=\"width: 161.25pt;\"\u003e \u003ccol width=\"219\" style=\"width: 164.25pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCQAG1BFD\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG3AFG\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCCBG1BED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCQCG1BHF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG1AHH\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCCBG3ANE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCQCG1BGK\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG1ACC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200PCCAG2ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCRAG1ACC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG3ADC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCDAH1BHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCTGG1AFF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCEAG1BRE\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCDAH1BHE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200EXPSG1ABB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCEAG1BSF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200DCFBG1BLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200EXPSG1ACB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCEAG1BTF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200PTBAG1AEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200QTBAG1ADC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCCAG1BAA\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200DTBAG1AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TBQBG1ACB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200DTBBG1ABB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCQCG1BKG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TBQAG1ABB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCPSG1AME\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCQAG1BHF-w01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200RTBAG2AHC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCPSG1ARE\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200SDCCG5AHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200SDCCG1AEC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200GDPAG1ALF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200SLCCG3AGH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE General Electric","offers":[{"title":"Default Title","offer_id":68427696406837,"sku":"IS200ECTBG3A","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/IS200ECTBG3A_Cocoai.jpg?v=1795171932","url":"https:\/\/www.newgenplc.com\/vi\/products\/is200ectbg3a-ge-ex2100-exciter-contact-terminal-board","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}