{"product_id":"ge-multilin-ur-8fh-ct-vt-input-module","title":"GE Multilin UR-8FH CT\/VT Input Module","description":"\u003ch2\u003e\n\u003cimg height=\"25\" width=\"26\" alt=\"GE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eConfigured for CT and VT signal acquisition in the GE Multilin UR Series, the \u003cstrong\u003eGE Multilin UR-8FH\u003c\/strong\u003e (\u003cstrong\u003eUR-8FH\u003c\/strong\u003e CT\/VT Input Module) provides direct electrical interfacing for protection, metering, monitoring, and control functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGE Multilin UR-8FH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eUR Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eCT\/VT Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Inputs\u003c\/td\u003e\n\u003ctd\u003eStandard CT input signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003e0.1 - 10 x CT rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.5% up to 2 x CT rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Delay\u003c\/td\u003e\n\u003ctd\u003e0.10 - 600.00 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTiming Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 15 cm x 18 cm x 4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eCT\/VT signal acquisition for UR Series protection and control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Signal Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe UR-8FH provides the relay with physical CT\/VT input channels for electrical measurement. These inputs supply the measurement data required by protection, metering, fault recording, and load-monitoring functions.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the module operates as part of the UR Series hardware architecture rather than as a standalone measurement instrument. The relay processes the acquired transformer signals and applies configured protection and control logic.\u003c\/p\u003e\n\u003cp\u003eThe supplied specifications state a current operating range of 0.1 - 10 x the CT rating, with +\/- 0.5% accuracy specified up to 2 x the CT rating. Programmable timing ranges from 0.10 - 600.00 s, with stated timing accuracy of +\/- 3%.\u003c\/p\u003e\n\u003cp\u003eFor system integration, installation personnel should verify the installed UR relay configuration, CT\/VT wiring arrangement, terminal assignments, and applicable hardware revision before energization.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of signals does the UR-8FH process?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The UR-8FH is specified as a CT\/VT input module for acquiring current and voltage transformer signals within GE Multilin UR Series relay hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What current range does the supplied specification identify?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The specified operating range is 0.1 - 10 x the CT rating, with +\/- 0.5% accuracy stated up to 2 x the CT rating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the supplied data specify power consumption or operating temperature?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The supplied information does not provide specific power consumption or operating temperature values. These parameters should therefore be verified against the applicable GE hardware documentation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the UR relay model and hardware configuration before installing the module.\u003c\/li\u003e\n\u003cli\u003eConfirm CT and VT circuit identification against the approved protection wiring drawings.\u003c\/li\u003e\n\u003cli\u003eDe-energize and isolate applicable circuits before performing wiring or module installation.\u003c\/li\u003e\n\u003cli\u003eMaintain correct CT polarity and phase identification throughout the input circuit.\u003c\/li\u003e\n\u003cli\u003eKeep CT\/VT signal wiring separated from high-current power conductors where practical.\u003c\/li\u003e\n\u003cli\u003eRoute low-level measurement wiring to minimize electromagnetic coupling and induced noise.\u003c\/li\u003e\n\u003cli\u003eApply cable shielding and grounding according to the relay system installation specification.\u003c\/li\u003e\n\u003cli\u003eInspect terminals, connectors, and module seating before applying operating power.\u003c\/li\u003e\n\u003cli\u003eVerify configured CT\/VT ratios and measurement scaling before placing protection functions into service.\u003c\/li\u003e\n\u003cli\u003ePerform functional and secondary-injection testing according to the applicable protection-system commissioning procedure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\" alt=\"GE\" width=\"26\" height=\"25\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: GE Multilin \u003cstrong\u003e350 Feeder\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eThe GE General Electric Mark VI \u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable height=\"253\" width=\"656\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\" style=\"height: 253px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"222\"\u003e \u003ccol width=\"215\"\u003e \u003ccol width=\"219\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ICBDH1ABB\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210MACCH2AGG\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS220YAICS1AJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS220PPRAH1A\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210AEBIH1BEA\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS220YDIAS1AK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS220UCSAH1A\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ISBEH1ABB\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS220YDOAS1AJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ACLEH1BCB\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TBAIH1CDC\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS420ESWBH3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200EPSMG2AED\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210AEDBH4AGD\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS420UCSCS2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200EROCH1ABC\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200AEADH4ADA\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS410JPDHG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ERIOH1ABC\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200REBFH1BBA\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TBAIS1CED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ERDDH1ABB\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210AEBIH3BED\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TBCIS2CCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200DSPXH1DBD\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS220PCLAH1A\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TRLYS1BGG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS230TRLSH2B\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS420UCSCH1C\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS230TAISH2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS220PDIAH1B\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200DSPXH1DBD\/DSPXH1D\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS230TCISH6C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e    \u003c\/span\u003e\u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"GE General Electric","offers":[{"title":"Default Title","offer_id":53461465202997,"sku":"UR-8FH","price":333.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/UR-8FH_Cocoai.jpg?v=1788518924","url":"https:\/\/www.newgenplc.com\/vi\/products\/ge-multilin-ur-8fh-ct-vt-input-module","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}