{"product_id":"cc-paoh01-51405039-176-hart-analog-output-module-honeywell","title":"CC-PAOH01 51405039-176 | HART Analog Output Module | Honeywell","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Honeywell_480x480.png?v=1697038586\" alt=\"\" width=\"68\" height=\"13\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAOH01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51405038-175\u003c\/strong\u003e Analog Input Module \/ HART Analog Output Module, operates as a dedicated hardware component for high-level analog signal conversion and field device telemetry within Experion PKS Series C control system networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PAOH01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternate Part Number\u003c\/td\u003e\n\u003ctd\u003e51405038-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0 lbs 12.8 oz (0.4 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e1.8 in x 5.5 in x 6.3 in (4.6 cm x 14.0 cm x 16.0 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8538907080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Location\u003c\/td\u003e\n\u003ctd\u003eWebster, NY USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module with HART \/ Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module integrates a dedicated 4-20 mA HART loop protocol layer, enabling bidirectional digital data modulation superimposed on the standard analog signaling path. This allows simultaneous transmission of primary process variables and secondary diagnostics from smart field instruments to the controller interface. To ensure signal integrity under severe common-mode voltage differentials, the architecture features robust channel-to-channel isolation. This galvanic isolation barrier prevents cross-talk and mitigates ground loop current propagation, protecting internal bus logic from external field electrical transients and high-frequency noise interference.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swapping under live backplane power conditions?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports online insertion and removal (OIR) within redundant configurations, provided the chassis grounding circuit remains continuous to prevent electrostatic discharge or bus disruption.\u003c\/p\u003e\n\u003cp\u003eQ: What is the primary function of the integrated HART capability on this analog channel interface?\u003c\/p\u003e\n\u003cp\u003eA: The HART subsystem permits pass-through routing of digital device variables, device status registers, and configuration commands alongside the primary 4-20 mA analog output execution loop without disrupting control signals.\u003c\/p\u003e\n\u003cp\u003eQ: How should unused channels be handled to prevent fault indications on the controller diagnostics?\u003c\/p\u003e\n\u003cp\u003eA: Unused channels should be disabled via the system configuration software utility or terminated using an appropriate external loop resistance across the physical terminal blocks to prevent open-circuit alarms.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the I\/O termination assembly is rigidly mounted to the DIN rail prior to mating the electronic module to prevent pin misalignment on the backplane connection.\u003c\/li\u003e\n\u003cli\u003eAll field wiring signal loops must utilize shielded twisted-pair cables, with the outer shield drain wire terminated exclusively at a single, dedicated instrument clean earth ground point.\u003c\/li\u003e\n\u003cli\u003eMaintain physical separation between low-voltage DC analog signal conduits and high-voltage AC power distribution cabling to minimize electromagnetic coupling induced loop errors.\u003c\/li\u003e\n\u003cli\u003eConfirm that the maximum loop impedance, including the field instrument load and wiring resistance, does not exceed the designated channel drive capacity under full 20 mA loop saturation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"13\" width=\"68\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Honeywell_480x480.png?v=1697038586\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Honeywell Experion PKS(C200,C300)\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: \u003cspan\u003e USA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"13\" width=\"68\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Honeywell_480x480.png?v=1697038586\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof Honeywell\u003c\/h2\u003e\n\u003ctable width=\"589\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\"\u003eFC-SDO-1624\u003c\/td\u003e\n\u003ctd width=\"135\"\u003e8C-PAIH51\u003c\/td\u003e\n\u003ctd width=\"268\"\u003eMC-TAMR03 51309218-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-TSDI-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PAIH51*E\u003c\/td\u003e\n\u003ctd\u003eMC-TAOY22 51204172-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-TSDO-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PAIH52\u003c\/td\u003e\n\u003ctd\u003eMU-TMCN02 561401846-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFS-TSAI-1620M\u003c\/td\u003e\n\u003ctd\u003e8C-PAIN01\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH02 51304453-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFS-TSDI-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PAOH51\u003c\/td\u003e\n\u003ctd\u003eMC-TAIL02 51304437-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-RUSIO-3224\u003c\/td\u003e\n\u003ctd\u003e8C-PAON01\u003c\/td\u003e\n\u003ctd\u003eMC-TDID72 51303928-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-SDI-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PCNT01\u003c\/td\u003e\n\u003ctd\u003eMC-TDODI3 51304650-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-BKM-0001\u003c\/td\u003e\n\u003ctd\u003e8C-PDIL51\u003c\/td\u003e\n\u003ctd\u003eMC-TDOY23 51204166-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-IO-0001\u003c\/td\u003e\n\u003ctd\u003e8C-PDILAI\u003c\/td\u003e\n\u003ctd\u003eMU-KLAM06 51304465-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-PSU-UNI2450U\u003c\/td\u003e\n\u003ctd\u003e8C-PDOD51\u003c\/td\u003e\n\u003ctd\u003eMU-TAIH02 51304453-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-QPP-0001\u003c\/td\u003e\n\u003ctd\u003e8C-TAID51\u003c\/td\u003e\n\u003ctd\u003eMU-TAMR03 501309218-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-SAI-1620M\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX51\u003c\/td\u003e\n\u003ctd\u003eMU-TAOX12 51304335-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-USI-0001\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX61\u003c\/td\u003e\n\u003ctd\u003eMU-TDID72 51303928-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-PAOX01\u003c\/td\u003e\n\u003ctd\u003e8C-TAOX61\u003c\/td\u003e\n\u003ctd\u003eMU-TDOD12 51304423-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-PFB801\u003c\/td\u003e\n\u003ctd\u003e8C-TCNT01\u003c\/td\u003e\n\u003ctd\u003eMU-TDOR22 51304427-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-PPIX01\u003c\/td\u003e\n\u003ctd\u003eTC-CCN013\u003c\/td\u003e\n\u003ctd\u003eDC-TFB412 51307618-176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-TAID11\u003c\/td\u003e\n\u003ctd\u003eTC-CCR012\u003c\/td\u003e\n\u003ctd\u003eTK-IOLI01 51403427-175 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC-TAOX11\u003c\/td\u003e\n\u003ctd\u003eTC-IAH161\u003c\/td\u003e\n\u003ctd\u003eTK-PPD011 51309241-175 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC-IDJ161\u003c\/td\u003e\n\u003ctd\u003eTC-OAV081\u003c\/td\u003e\n\u003ctd\u003eTK-PRS021 51404305-275 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC-IXL061\u003c\/td\u003e\n\u003ctd\u003e10300\/1\/1\u003c\/td\u003e\n\u003ctd\u003eCC-TAIX01 51308363-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDCS3000LCN\u003c\/td\u003e\n\u003ctd\u003e51305887-150\u003c\/td\u003e\n\u003ctd\u003e8C-PAOHA1 51454469-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTK-FPDXX2\u003c\/td\u003e\n\u003ctd\u003e10012\/1\/2\u003c\/td\u003e\n\u003ctd\u003e8C-PAIMA1 51454473-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53053959668021,"sku":"51405039-176","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/51405039-176.jpg?v=1782889834","url":"https:\/\/www.newgenplc.com\/vi\/products\/cc-paoh01-51405039-176-hart-analog-output-module-honeywell","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}