{"product_id":"spw481-yokogawa-centum-vp-power-supply-module","title":"SPW481 |  Yokogawa CENTUM VP Power Supply Module","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/YOKOGAWA_480x480.png?v=1697472085\" alt=\"\" width=\"70\" height=\"17\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"ybc-p\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa SPW481\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSPW481\u003c\/strong\u003e Power Supply Module, provides AC-to-DC power conversion for compatible Yokogawa control system units. It accepts a specified AC input and supplies DC power to system hardware. The supplied documentation describes single-module and dual-redundant configurations for Field Control Units (FCUs), FIO node units, and optical ESB bus repeater units.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSPW481\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-120 V AC +\/- 10% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz +\/- 3 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMaximum 200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e40-100 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eGreater than 85% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput-to-Output Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V AC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eSingle or dual-redundant, using P1 and P2 slots as specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Units\u003c\/td\u003e\n\u003ctd\u003eField Control Units (FCUs), FIO node units, optical ESB bus repeater units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 51 x 203 x 146 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.9-1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot-Swap Capability\u003c\/td\u003e\n\u003ctd\u003eReported in the supplied description\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Options\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 and extended temperature options are mentioned; exact SPW481 applicability requires confirmation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eAC Input and Redundant Power Configuration\u003c\/h3\u003e\n\u003cp\u003eThe SPW481 description specifies a nominal input range of 100-120 V AC with a tolerance of +\/- 10%. The stated input frequency is 50\/60 Hz +\/- 3 Hz, with maximum input consumption of 200 VA.\u003c\/p\u003e\n\u003cp\u003eFor a dual-redundant arrangement, the supplied information identifies two matching modules installed in slots P1 and P2. Confirm the target unit's hardware configuration and power supply compatibility before installation. The provided data does not establish the redundancy transfer time, output voltage, or load-sharing behavior.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What input voltage does the SPW481 support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied model-specific description states 100-120 V AC +\/- 10%. The separate 100-240 V AC specification has not been verified for this exact model and should not be treated as its confirmed input range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can two SPW481 modules provide redundant power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied description identifies a dual-redundant arrangement using two matching modules in slots P1 and P2. Confirm the applicable system manual for redundancy behavior, permissible load, and module replacement procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the SPW481 hot-swappable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied description reports hot-swap capability. However, the permitted removal procedure and any restrictions depend on the host unit and system configuration. Consult the relevant Yokogawa hardware manual before removing a powered module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the module nameplate and host-unit documentation before connecting the AC input.\u003c\/li\u003e\n\u003cli\u003eConfirm that the incoming supply voltage and frequency fall within the specifications for the exact module variant.\u003c\/li\u003e\n\u003cli\u003eInstall the module in the designated power supply slot and secure it according to the host unit's instructions.\u003c\/li\u003e\n\u003cli\u003eFor redundant installations, confirm module compatibility, slot assignment, and system configuration before energizing the equipment.\u003c\/li\u003e\n\u003cli\u003eKeep AC input wiring separate from low-level analog signal and communication wiring where practical.\u003c\/li\u003e\n\u003cli\u003eFollow the host system's protective grounding and bonding requirements. Do not use signal cable shields as protective earth conductors.\u003c\/li\u003e\n\u003cli\u003eConfirm that the enclosure provides the required cooling and environmental conditions.\u003c\/li\u003e\n\u003cli\u003eDo not remove or insert the module under power unless the applicable hardware manual explicitly permits that procedure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\n\u003cimg height=\"17\" width=\"70\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/YOKOGAWA_480x480.png?v=1697472085\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCountry of Origin: Japan\/Singapore\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"17\" width=\"70\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/YOKOGAWA_480x480.png?v=1697472085\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof\u003cspan\u003e \u003cu\u003eYOKOGAWA\u003c\/u\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable height=\"471\" width=\"498\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"188\"\u003e \u003ccol width=\"176\"\u003e \u003ccol width=\"134\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd width=\"188\" height=\"23\" class=\"et2\"\u003eANB10D-425\/CU2N\u003c\/td\u003e\n\u003ctd width=\"176\" class=\"et2\"\u003eSDV144-S63\u003c\/td\u003e\n\u003ctd width=\"134\" class=\"et2\"\u003eSAI143-S53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eAAI143-H50\/K4A00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eALE111-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP451-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eEC402-50 S1\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP471-00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSPW482-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eAAI143-H50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP461-51\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-10 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"45\"\u003e\n\u003ctd height=\"45\" class=\"et2\"\u003eSAI143-H63\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-10\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-50 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eAAI143-H50\/A4S00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI533-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eACG10S-F2121 S4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eANB10D-420\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSNT401-53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAIP826-2 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAFF50D-H41201\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eADV161-P50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAV144-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSEC402-51\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAI143-S53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-420\/CU2N\/NDEL\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eANB10D-421\/CU2N\/NDEL\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI143-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eADV151-P53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAAI543-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eDP97-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003ePW484-50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eYNT512D-Q12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eCP345\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAAI143-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-410\/S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAB841-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-420 S2\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eNFCP100-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAF135-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-51\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-10 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAI141-S00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP461-51 S1\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI143-H33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAI141-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP461-51 S2\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI143-H03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAI841-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSNB10D-225\/CU2T\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP345 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAR181-S00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAAI141-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP451-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFDV161-P00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAFV10D-S41211\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003ePW702 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFDV161-P50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-421\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAFV30D-A41452\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAR145-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-425\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eALE111-S50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":67741839753525,"sku":"SPW481","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/SPW481_Cocoai.jpg?v=1792224507","url":"https:\/\/www.newgenplc.com\/tr\/products\/spw481-yokogawa-centum-vp-power-supply-module","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}