{"product_id":"abb-red615e_1g-hbdbaaacnka1ana11g-line-differential-protection-relay","title":"ABB RED615E_1G HBDBAAACNKA1ANA11G  Line Differential Protection Relay","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\" alt=\"\" width=\"60\" height=\"25\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eConfigured for phase-segregated line differential protection in IEC 61850 substation networks, the \u003cstrong\u003eABB HBDBAAACNKA1ANA11G\u003c\/strong\u003e (\u003cstrong\u003eRED615\u003c\/strong\u003e Line Differential Protection Relay) provides direct physical and electrical execution for current and voltage signal processing, protection logic, and communication functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eABB HBDBAAACNKA1ANA11G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFinland \/ ABB production network\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eRelion RED615\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLine Differential Protection Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Function\u003c\/td\u003e\n\u003ctd\u003ePhase-segregated line differential protection, backup overcurrent protection, voltage and frequency supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003eCurrent inputs for 1 A \/ 5 A CT signals, voltage inputs for phase and residual voltage measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBinary Inputs\u003c\/td\u003e\n\u003ctd\u003eConfigurable digital status and control inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBinary Outputs\u003c\/td\u003e\n\u003ctd\u003eTrip, alarm, and control output contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eEthernet communication with IEC 61850, Modbus, DNP3, IEC 60870-5-103 support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eIEC 61850 MMS, GOOSE messaging, PRP and HSR redundancy support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Synchronization\u003c\/td\u003e\n\u003ctd\u003eIEEE 1588 v2 PTP, IRIG-B, SNTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eWide-range auxiliary supply, typically 48-250 VDC \/ 100-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact 615 series relay enclosure; exact dimensions depend on mounting configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Communication and Protection Processing\u003c\/h3\u003e\n\u003cp\u003eThe RED615 processes sampled current and voltage signals through dedicated measurement channels and executes line differential algorithms inside the relay processor. The relay compares protected line current values from both ends through communication channels and issues trip commands when differential current exceeds configured protection limits.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the relay supports IEC 61850 GOOSE messaging for high-speed peer-to-peer protection signaling. It can operate within PRP and HSR network architectures where redundant Ethernet communication paths maintain protection data exchange.\u003c\/p\u003e\n\u003cp\u003eABB industrial control platforms use deterministic communication structures for protection and automation systems. The RED615 supports IEC 61850 based substation communication, enabling integration with digital substation architectures and engineering tools.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ABB RED615 support direct CT and VT signal measurement?\u003cbr\u003eA: Yes. The RED615 accepts conventional current transformer and voltage transformer signals through configured analog input channels for protection and measurement functions.\u003c\/p\u003e\n\u003cp\u003eQ: Can the RED615 operate in redundant communication networks?\u003cbr\u003eA: Yes. The relay supports PRP and HSR Ethernet redundancy functions when the configured communication hardware and network topology are applied.\u003c\/p\u003e\n\u003cp\u003eQ: What protection communication protocol does the RED615 use for differential protection?\u003cbr\u003eA: The RED615 uses IEC 61850 communication functions, including MMS and GOOSE messaging, for protection coordination and substation data exchange.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the RED615 relay inside a suitable protection panel with controlled environmental conditions. Verify auxiliary power polarity and voltage range before energizing the device.\u003c\/p\u003e\n\u003cp\u003eTerminate CT and VT wiring according to the protection scheme drawings. Keep measurement circuits separated from high-voltage switching conductors to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eConnect Ethernet communication cables using the specified shielding and grounding practice. Maintain proper cable routing between protection wiring, communication wiring, and power circuits.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, verify relay configuration parameters, communication settings, binary input states, output contact operation, and protection logic using approved testing equipment.\u003c\/p\u003e\n\u003cp\u003eConfirm IEC 61850 communication mapping, GOOSE subscriptions, and time synchronization status before placing the protection system into service.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"25\" width=\"60\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Advant DCS\/800xA\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: \u003cspan\u003e \u003c\/span\u003e\u003cspan id=\"dnn_ctr1219_View_LabelCountryOfOrigin\"\u003eGermany\/Sweden\/Finland\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\" alt=\"\" width=\"60\" height=\"25\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof ABB\u003c\/h2\u003e\n\u003ctable width=\"774\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"437\"\u003e3BHB003154R0101 3BHL000389P0104  5SHX2645L0004\u003c\/td\u003e\n\u003ctd width=\"337\"\u003e3BHE02195R0124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE009681R0101 3BHB012961R0001 5SHX2645L0002\u003c\/td\u003e\n\u003ctd\u003eXVC724BE102 3BHE009017R0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE009681R0101 3BHB013088R0001 5SHY3545L0010\u003c\/td\u003e\n\u003ctd\u003eUNS3020 HIEE205010R0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE022333R0101 5SHX0660R0002 5SXE05-0158\u003c\/td\u003e\n\u003ctd\u003e3BHE003855R0001\/UNS 2882A-P,V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB005171R0101 3BHL000986P3105 5SHY3545L0002\u003c\/td\u003e\n\u003ctd\u003e3BHE009319R0001\/UNS 2881B-P,V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101 5SXE10-0181 5SHY6545L0001\u003c\/td\u003e\n\u003ctd\u003e3BHE009949R0002\/UNS 4881B,V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003387R0101 3BHL00385P0101 5SHX0845F0001\u003c\/td\u003e\n\u003ctd\u003e3BHE014967R0002\/UNS 2880B-P,V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003386R0101 3BHL000387P0101 5SHX1445H0002\u003c\/td\u003e\n\u003ctd\u003eUFC765AE102 3BHE003604R0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101\/5SXE10-0181\/5SHY55L4500\u003c\/td\u003e\n\u003ctd\u003eXVC767AE105 3BHB007209R0105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101\/5SXE10-0181\/5SHY55L4520\u003c\/td\u003e\n\u003ctd\u003eXVC768115 3BHB0072R115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003230R0101 3BHL000392P0101 5SHX1060H0001\u003c\/td\u003e\n\u003ctd\u003eXVC768115 3BHB007211R115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003387R0101 3BHL000385P0101 5SHX0845F0001\u003c\/td\u003e\n\u003ctd\u003eAFC094AE02 HIEE200130R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SXE10-0181 5SHY55L4520 AC10272001R0101\u003c\/td\u003e\n\u003ctd\u003eARC093AE01 HIEE300690R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53188147216693,"sku":"RED615E_1G HBDBAAACNKA1ANA11G","price":8888.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/RED615E_1GHBDBAAACNKA1ANA11G.jpg?v=1784536439","url":"https:\/\/www.newgenplc.com\/tr\/products\/abb-red615e_1g-hbdbaaacnka1ana11g-line-differential-protection-relay","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}