{"product_id":"3bhb003386r0101-igct-power-semiconductor-assembly-abb","title":"3BHB003386R0101 IGCT Power Semiconductor Assembly | ABB","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\" alt=\"\" width=\"60\" height=\"25\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-power switching in medium-voltage converter systems, the \u003cstrong\u003eABB 3BHB003386R0101\u003c\/strong\u003e (\u003cstrong\u003e5SHX1445H0002\u003c\/strong\u003e IGCT power semiconductor) provides direct electrical switching through the associated \u003cstrong\u003e3BHL000387P0101\u003c\/strong\u003e gate driver. The assembly controls high-current semiconductor conduction and turn-off within compatible ABB power conversion equipment.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3BHB003386R0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIGCT Power Semiconductor Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated Gate Driver\u003c\/td\u003e\n\u003ctd\u003e3BHL000387P0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSemiconductor Device\u003c\/td\u003e\n\u003ctd\u003e5SHX1445H0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSemiconductor Technology\u003c\/td\u003e\n\u003ctd\u003eIntegrated Gate-Commutated Thyristor (IGCT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepetitive Peak Off-State Voltage (VDRM)\u003c\/td\u003e\n\u003ctd\u003eUp to 4500 V, as provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage On-State Current (IT(AV))\u003c\/td\u003e\n\u003ctd\u003eApprox. 1450 A to 1500 A class, as provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Characteristics\u003c\/td\u003e\n\u003ctd\u003eHigh-power switching, low-loss converter operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Interface\u003c\/td\u003e\n\u003ctd\u003eDouble-sided liquid cooling arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Power Switching and Gate Drive Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 5SHX1445H0002 provides the main semiconductor switching function, while the 3BHL000387P0101 gate driver supplies the required gate-control interface. Therefore, the assembly must be treated as a coordinated power-switching unit rather than as an independent logic I\/O module.\u003c\/p\u003e\n\u003cp\u003eThe IGCT structure controls high-current conduction and turn-off through direct gate control. In addition, the power circuit and gate-drive circuit must maintain the electrical relationships specified by the applicable ABB converter design.\u003c\/p\u003e\n\u003cp\u003eThe stated voltage class reaches up to 4500 V VDRM, while the supplied current information places the device in the approximately 1450 A to 1500 A class. These values describe the semiconductor class supplied in the provided data and should be checked against the applicable ABB device documentation before equipment-level design.\u003c\/p\u003e\n\u003cp\u003eThe assembly uses a double-sided liquid-cooling arrangement. Consequently, the mechanical mounting surfaces, cooling interfaces, electrical insulation, and gate-drive connections must remain compatible with the original converter assembly.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the 3BHB003386R0101 a standalone control module?\u003c\/p\u003e\n\u003cp\u003eA: No. The supplied identification describes a power semiconductor assembly associated with the 3BHL000387P0101 gate driver and 5SHX1445H0002 IGCT. It is not a PLC or conventional I\/O module.\u003c\/p\u003e\n\u003cp\u003eQ: What is the function of the 3BHL000387P0101?\u003c\/p\u003e\n\u003cp\u003eA: The 3BHL000387P0101 is the associated gate driver unit. It provides the gate-control interface required to operate the 5SHX1445H0002 IGCT.\u003c\/p\u003e\n\u003cp\u003eQ: What cooling arrangement does this assembly use?\u003c\/p\u003e\n\u003cp\u003eA: The supplied data specifies a double-sided liquid-cooling arrangement. The actual cooling hardware and mounting procedure must follow the applicable ABB converter documentation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the assembly only in equipment designed for the specified ABB IGCT and gate-driver configuration. First, verify the complete identification of 3BHB003386R0101, 3BHL000387P0101, and 5SHX1445H0002 against the equipment documentation.\u003c\/p\u003e\n\u003cp\u003eBefore installation, isolate the converter and verify that the power circuit has reached a safe de-energized state. Follow the equipment manufacturer's discharge and electrical isolation procedures because the semiconductor operates in a high-voltage power circuit.\u003c\/p\u003e\n\u003cp\u003eClean and inspect the semiconductor mounting and cooling interfaces before assembly. Ensure that the specified liquid-cooling interface is correctly aligned and that no contamination remains between mating surfaces.\u003c\/p\u003e\n\u003cp\u003eNext, install the electrical and gate-drive connections according to the original ABB connection arrangement. Keep power conductors and gate-control wiring routed according to the converter's original physical layout. Avoid unnecessary parallel routing between high-current switching conductors and sensitive gate-control connections.\u003c\/p\u003e\n\u003cp\u003eFinally, inspect mechanical fastening, electrical insulation, cooling connections, and connector engagement before energizing the converter. Do not substitute mounting hardware, cooling arrangements, or gate-drive components without confirming compatibility with the applicable ABB equipment documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"25\" width=\"60\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\" style=\"font-size: 0.875rem;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eOther Attributes\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Advant DCS\/800xA\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: \u003cspan\u003e \u003c\/span\u003e\u003cspan id=\"dnn_ctr1219_View_LabelCountryOfOrigin\"\u003eGermany\/Sweden\/Finland\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\" alt=\"\" width=\"60\" height=\"25\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof ABB\u003c\/h2\u003e\n\u003ctable width=\"774\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"437\"\u003e3BHB003154R0101 3BHL000389P0104  5SHX2645L0004\u003c\/td\u003e\n\u003ctd width=\"337\"\u003e3BHE02195R0124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE009681R0101 3BHB012961R0001 5SHX2645L0002\u003c\/td\u003e\n\u003ctd\u003eXVC724BE102 3BHE009017R0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE009681R0101 3BHB013088R0001 5SHY3545L0010\u003c\/td\u003e\n\u003ctd\u003eUNS3020 HIEE205010R0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE022333R0101 5SHX0660R0002 5SXE05-0158\u003c\/td\u003e\n\u003ctd\u003e3BHE003855R0001\/UNS 2882A-P,V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB005171R0101 3BHL000986P3105 5SHY3545L0002\u003c\/td\u003e\n\u003ctd\u003e3BHE009319R0001\/UNS 2881B-P,V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101 5SXE10-0181 5SHY6545L0001\u003c\/td\u003e\n\u003ctd\u003e3BHE009949R0002\/UNS 4881B,V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003387R0101 3BHL00385P0101 5SHX0845F0001\u003c\/td\u003e\n\u003ctd\u003e3BHE014967R0002\/UNS 2880B-P,V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003386R0101 3BHL000387P0101 5SHX1445H0002\u003c\/td\u003e\n\u003ctd\u003eUFC765AE102 3BHE003604R0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101\/5SXE10-0181\/5SHY55L4500\u003c\/td\u003e\n\u003ctd\u003eXVC767AE105 3BHB007209R0105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101\/5SXE10-0181\/5SHY55L4520\u003c\/td\u003e\n\u003ctd\u003eXVC768115 3BHB0072R115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003230R0101 3BHL000392P0101 5SHX1060H0001\u003c\/td\u003e\n\u003ctd\u003eXVC768115 3BHB007211R115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003387R0101 3BHL000385P0101 5SHX0845F0001\u003c\/td\u003e\n\u003ctd\u003eAFC094AE02 HIEE200130R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SXE10-0181 5SHY55L4520 AC10272001R0101\u003c\/td\u003e\n\u003ctd\u003eARC093AE01 HIEE300690R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53625697075509,"sku":"3BHB003386R0101 3BHL000387P0101 5SHX1445H0002","price":8888.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/3BHB003386R01013BHL000387P01015SHX1445H0002_Cocoai.jpg?v=1790056218","url":"https:\/\/www.newgenplc.com\/tr\/products\/3bhb003386r0101-igct-power-semiconductor-assembly-abb","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}