{"product_id":"ret615-abb-transformer-protection-and-control-ied","title":"RET615 | ABB | Transformer Protection and Control IED","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\" alt=\"\" width=\"60\" height=\"25\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eConfigured for transformer differential protection, earth-fault protection, measurement, and circuit-breaker control, the \u003cstrong\u003eABB RET615 HBTABABBAAC1ANN11G\u003c\/strong\u003e (\u003cstrong\u003eRET615\u003c\/strong\u003e Transformer Protection and Control IED) provides direct electrical and data-processing functions within ABB Relion 615 series protection systems. The device accepts CT and VT signals, processes protection algorithms, controls switching equipment, and exchanges protection and automation data through supported communication interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRET615 HBTABABBAAC1ANN11G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eRET615\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eRelion 615 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTransformer Protection and Control IED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eTransformer protection, control, measurement, and supervision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003eConfigurable current and voltage inputs for CT and VT circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBinary I\/O\u003c\/td\u003e\n\u003ctd\u003eConfigurable binary inputs and outputs for trip, indication, status, and control functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eTransformer differential, restricted earth fault, overcurrent, earth fault, thermal overload, overvoltage, undervoltage, and frequency protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Functions\u003c\/td\u003e\n\u003ctd\u003eCircuit breaker control, status monitoring, and interlocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eIEC 61850, including GOOSE messaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Protocols\u003c\/td\u003e\n\u003ctd\u003eDNP3, IEC 60870-5-103, and Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd\u003eOptical or galvanic Ethernet interfaces, depending on hardware configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Topology\u003c\/td\u003e\n\u003ctd\u003eSupports applicable redundant Ethernet architectures such as PRP and HSR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurements\u003c\/td\u003e\n\u003ctd\u003eCurrent, voltage, frequency, active power, reactive power, and energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording\u003c\/td\u003e\n\u003ctd\u003eDisturbance recording, event recording, and fault record storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHMI\u003c\/td\u003e\n\u003ctd\u003eLocal graphical Human-Machine Interface with display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFlush-mounted or wall-mounted configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Design\u003c\/td\u003e\n\u003ctd\u003eCompact plug-in or draw-out construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eConfiguration dependent; not specified in the supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eConfiguration dependent; not specified in the supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eConfiguration dependent; not specified in the supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eConfiguration dependent; not specified in the supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Relion 615 Protection Architecture\u003c\/h3\u003e\n\u003cp\u003eThe RET615 processes transformer-side current and voltage measurements through configurable protection functions. Differential protection compares transformer current quantities and can provide trip decisions for internal transformer faults. In addition, restricted earth-fault protection provides a dedicated earth-fault detection function for the protected zone.\u003c\/p\u003e\n\u003cp\u003eThe relay also supports overcurrent, earth-fault, thermal, voltage, and frequency protection functions. Therefore, engineers can combine protection stages with circuit-breaker control, interlocking, measurement, and status supervision within the same IED configuration.\u003c\/p\u003e\n\u003cp\u003eFor automation communication, IEC 61850 provides station-level data exchange, while GOOSE supports high-speed peer-to-peer event messaging between compatible protection and control devices. Furthermore, the available Ethernet architecture can support redundant communication arrangements when the installed hardware configuration provides the required interfaces.\u003c\/p\u003e\n\u003cp\u003eABB 615 series I\/O configuration determines the available physical signal capacity. Consequently, the exact binary I\/O allocation, communication interfaces, auxiliary supply arrangement, and application functions must be verified against the complete factory order code \u003cstrong\u003eHBTABABBAAC1ANN11G\u003c\/strong\u003e before replacement or engineering work.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the RET615 support transformer differential protection?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The RET615 provides stabilized and instantaneous differential protection functions as part of its transformer protection application.\u003c\/p\u003e\n\u003cp\u003eQ: Which communication protocol is used for substation automation?\u003c\/p\u003e\n\u003cp\u003eA: IEC 61850 is supported for substation automation, including GOOSE messaging. The supplied data also identifies DNP3, IEC 60870-5-103, and Modbus support.\u003c\/p\u003e\n\u003cp\u003eQ: Can the exact I\/O and communication configuration be determined from RET615 alone?\u003c\/p\u003e\n\u003cp\u003eA: No. The complete order code \u003cstrong\u003eHBTABABBAAC1ANN11G\u003c\/strong\u003e identifies the specific factory hardware and software configuration. Engineers should verify the applicable ABB documentation before installation or replacement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the complete RET615 order code against the project protection and control drawings before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm CT and VT secondary circuits against the relay configuration and approved wiring diagrams.\u003c\/li\u003e\n\u003cli\u003eKeep current, voltage, binary signal, and communication wiring separated according to the applicable site wiring standard.\u003c\/li\u003e\n\u003cli\u003eUse shielded communication and signal cables where the installation design requires electromagnetic interference control.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the approved substation grounding and EMC scheme.\u003c\/li\u003e\n\u003cli\u003eVerify protective earth and equipment grounding connections before energizing the relay.\u003c\/li\u003e\n\u003cli\u003eConfirm auxiliary supply voltage and polarity from the configuration-specific ABB documentation before applying power.\u003c\/li\u003e\n\u003cli\u003eCheck binary input and output assignments against the configured application before connecting trip or close circuits.\u003c\/li\u003e\n\u003cli\u003eTest circuit-breaker interlocking and status feedback independently before enabling operational control.\u003c\/li\u003e\n\u003cli\u003ePerform CT secondary circuit checks before commissioning differential or earth-fault protection.\u003c\/li\u003e\n\u003cli\u003eValidate IEC 61850 communication, GOOSE subscriptions, and network redundancy settings where applicable.\u003c\/li\u003e\n\u003cli\u003eDo not substitute hardware, communication interfaces, or firmware without confirming compatibility with the complete RET615 configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cimg height=\"25\" width=\"60\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Advant DCS\/800xA\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: \u003cspan\u003e \u003c\/span\u003e\u003cspan id=\"dnn_ctr1219_View_LabelCountryOfOrigin\"\u003eGermany\/Sweden\/Finland\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\" alt=\"\" width=\"60\" height=\"25\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof ABB\u003c\/h2\u003e\n\u003ctable width=\"774\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"437\"\u003e3BHB003154R0101 3BHL000389P0104  5SHX2645L0004\u003c\/td\u003e\n\u003ctd width=\"337\"\u003e3BHE02195R0124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE009681R0101 3BHB012961R0001 5SHX2645L0002\u003c\/td\u003e\n\u003ctd\u003eXVC724BE102 3BHE009017R0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE009681R0101 3BHB013088R0001 5SHY3545L0010\u003c\/td\u003e\n\u003ctd\u003eUNS3020 HIEE205010R0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE022333R0101 5SHX0660R0002 5SXE05-0158\u003c\/td\u003e\n\u003ctd\u003e3BHE003855R0001\/UNS 2882A-P,V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB005171R0101 3BHL000986P3105 5SHY3545L0002\u003c\/td\u003e\n\u003ctd\u003e3BHE009319R0001\/UNS 2881B-P,V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101 5SXE10-0181 5SHY6545L0001\u003c\/td\u003e\n\u003ctd\u003e3BHE009949R0002\/UNS 4881B,V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003387R0101 3BHL00385P0101 5SHX0845F0001\u003c\/td\u003e\n\u003ctd\u003e3BHE014967R0002\/UNS 2880B-P,V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003386R0101 3BHL000387P0101 5SHX1445H0002\u003c\/td\u003e\n\u003ctd\u003eUFC765AE102 3BHE003604R0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101\/5SXE10-0181\/5SHY55L4500\u003c\/td\u003e\n\u003ctd\u003eXVC767AE105 3BHB007209R0105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101\/5SXE10-0181\/5SHY55L4520\u003c\/td\u003e\n\u003ctd\u003eXVC768115 3BHB0072R115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003230R0101 3BHL000392P0101 5SHX1060H0001\u003c\/td\u003e\n\u003ctd\u003eXVC768115 3BHB007211R115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003387R0101 3BHL000385P0101 5SHX0845F0001\u003c\/td\u003e\n\u003ctd\u003eAFC094AE02 HIEE200130R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SXE10-0181 5SHY55L4520 AC10272001R0101\u003c\/td\u003e\n\u003ctd\u003eARC093AE01 HIEE300690R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53333678424373,"sku":"RET615 HBTABABBAAC1ANN11G","price":8888.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/RET615HBTABABBAAC1ANN11G.jpg?v=1787132198","url":"https:\/\/www.newgenplc.com\/ru\/products\/ret615-abb-transformer-protection-and-control-ied","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}