{"product_id":"mc-ga1h13-honeywell-51304718-175-analog-input-module","title":"MC-GA1H13 Honeywell 51304718-175 Analog Input Module","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Honeywell_480x480.png?v=1697038586\" alt=\"\" width=\"68\" height=\"13\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MC-GA1H13 51304718-175\u003c\/strong\u003e is a 16-channel analog input module designed to acquire and process analog signals in industrial control systems. It supports 4-20 mA current signals and 1-5 VDC voltage signals, with 16-bit resolution for signal conversion. The module provides channel-to-system isolation and supports analog signal monitoring where accurate process data acquisition is required.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAnalog Input Function\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MC-GA1H13 accepts analog signals from field instruments and converts them into digital data for control system processing. It supports both 4-20 mA and 1-5 VDC input types, allowing it to interface with different transmitter signal formats.\u003c\/p\u003e\n\u003cp\u003eFor example, field transmitters can provide measurements such as pressure, flow, temperature, or liquid level through standard analog signals. The control system can then use these values for monitoring, alarms, control logic, and process regulation, depending on the configured application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal Processing and Accuracy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module uses 16-bit resolution for analog-to-digital conversion, providing detailed signal representation across the configured input range. Its specified accuracy is +\/-0.1% of full scale, supporting precise measurement acquisition when the signal type and operating conditions match the module configuration.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the specified conversion time is 10 ms or less. This parameter defines the conversion performance of the module, although the overall control system update time may also depend on controller execution, I\/O communication, and configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIsolation and Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MC-GA1H13 provides 1500 VDC channel-to-system isolation according to the supplied specifications. This isolation helps separate the field signal circuits from the system electronics and reduces the direct transfer of electrical disturbances between them.\u003c\/p\u003e\n\u003cp\u003eIn addition, the listed diagnostic update rate is 100 ms. This represents the specified diagnostic update interval, which should not be confused with the analog conversion time or the overall process control scan rate.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-GA1H13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51304718-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 1-5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-System Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance (Current)\u003c\/td\u003e\n\u003ctd\u003e250 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance (Voltage)\u003c\/td\u003e\n\u003ctd\u003e1 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e10 ms or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Update Rate\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.2 x 12.7 x 5.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eListed Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000, Experion PKS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What input signals does the Honeywell MC-GA1H13 support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It supports 4-20 mA current signals and 1-5 VDC voltage signals. The input configuration must match the connected field transmitter and wiring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the resolution of the MC-GA1H13?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module provides 16-bit analog-to-digital conversion resolution. This determines the number of digital steps available to represent the configured analog input range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between conversion time and diagnostic update rate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Conversion time is specified as 10 ms or less, while the diagnostic update rate is 100 ms. They describe different module functions and should not be treated as the same timing parameter.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"13\" width=\"68\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Honeywell_480x480.png?v=1697038586\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Honeywell Experion PKS(C200,C300)\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: \u003cspan\u003e USA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"13\" width=\"68\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Honeywell_480x480.png?v=1697038586\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof Honeywell\u003c\/h2\u003e\n\u003ctable width=\"589\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\"\u003eFC-SDO-1624\u003c\/td\u003e\n\u003ctd width=\"135\"\u003e8C-PAIH51\u003c\/td\u003e\n\u003ctd width=\"268\"\u003eMC-TAMR03 51309218-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-TSDI-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PAIH51*E\u003c\/td\u003e\n\u003ctd\u003eMC-TAOY22 51204172-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-TSDO-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PAIH52\u003c\/td\u003e\n\u003ctd\u003eMU-TMCN02 561401846-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFS-TSAI-1620M\u003c\/td\u003e\n\u003ctd\u003e8C-PAIN01\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH02 51304453-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFS-TSDI-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PAOH51\u003c\/td\u003e\n\u003ctd\u003eMC-TAIL02 51304437-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-RUSIO-3224\u003c\/td\u003e\n\u003ctd\u003e8C-PAON01\u003c\/td\u003e\n\u003ctd\u003eMC-TDID72 51303928-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-SDI-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PCNT01\u003c\/td\u003e\n\u003ctd\u003eMC-TDODI3 51304650-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-BKM-0001\u003c\/td\u003e\n\u003ctd\u003e8C-PDIL51\u003c\/td\u003e\n\u003ctd\u003eMC-TDOY23 51204166-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-IO-0001\u003c\/td\u003e\n\u003ctd\u003e8C-PDILAI\u003c\/td\u003e\n\u003ctd\u003eMU-KLAM06 51304465-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-PSU-UNI2450U\u003c\/td\u003e\n\u003ctd\u003e8C-PDOD51\u003c\/td\u003e\n\u003ctd\u003eMU-TAIH02 51304453-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-QPP-0001\u003c\/td\u003e\n\u003ctd\u003e8C-TAID51\u003c\/td\u003e\n\u003ctd\u003eMU-TAMR03 501309218-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-SAI-1620M\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX51\u003c\/td\u003e\n\u003ctd\u003eMU-TAOX12 51304335-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-USI-0001\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX61\u003c\/td\u003e\n\u003ctd\u003eMU-TDID72 51303928-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-PAOX01\u003c\/td\u003e\n\u003ctd\u003e8C-TAOX61\u003c\/td\u003e\n\u003ctd\u003eMU-TDOD12 51304423-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-PFB801\u003c\/td\u003e\n\u003ctd\u003e8C-TCNT01\u003c\/td\u003e\n\u003ctd\u003eMU-TDOR22 51304427-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-PPIX01\u003c\/td\u003e\n\u003ctd\u003eTC-CCN013\u003c\/td\u003e\n\u003ctd\u003eDC-TFB412 51307618-176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-TAID11\u003c\/td\u003e\n\u003ctd\u003eTC-CCR012\u003c\/td\u003e\n\u003ctd\u003eTK-IOLI01 51403427-175 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC-TAOX11\u003c\/td\u003e\n\u003ctd\u003eTC-IAH161\u003c\/td\u003e\n\u003ctd\u003eTK-PPD011 51309241-175 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC-IDJ161\u003c\/td\u003e\n\u003ctd\u003eTC-OAV081\u003c\/td\u003e\n\u003ctd\u003eTK-PRS021 51404305-275 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC-IXL061\u003c\/td\u003e\n\u003ctd\u003e10300\/1\/1\u003c\/td\u003e\n\u003ctd\u003eCC-TAIX01 51308363-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDCS3000LCN\u003c\/td\u003e\n\u003ctd\u003e51305887-150\u003c\/td\u003e\n\u003ctd\u003e8C-PAOHA1 51454469-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTK-FPDXX2\u003c\/td\u003e\n\u003ctd\u003e10012\/1\/2\u003c\/td\u003e\n\u003ctd\u003e8C-PAIMA1 51454473-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":68502275293493,"sku":"MC-GA1H13","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/MC-GA1H1351304718-175_Cocoai.jpg?v=1795688241","url":"https:\/\/www.newgenplc.com\/ru\/products\/mc-ga1h13-honeywell-51304718-175-analog-input-module","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}