{"product_id":"ge-ds200tcpsg1a-mark-v-power-supply-board","title":"GE DS200TCPSG1A Mark V Power Supply Board","description":"\u003ch2\u003e\n\u003cimg height=\"25\" width=\"26\" alt=\"GE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe DS200TCPSG1A is a DC power supply board manufactured by General Electric (GE) for the Mark V series. It converts the 125 VDC input from the power distribution board into regulated voltage levels required by control system components. Furthermore, it provides multiple DC outputs, including +5 VDC, +24 VDC, +\/-15 VDC, and +\/-24 VDC, through dedicated connectors for power distribution.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TCPSG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDC Power Supply Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltages\u003c\/td\u003e\n\u003ctd\u003e+5 VDC, +24 VDC, +\/-15 VDC, +\/-24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power Source\u003c\/td\u003e\n\u003ctd\u003eTCPD board in the PD core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e2PL, J1, JC, JP1, JP2, X1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuses\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Configuration\u003c\/td\u003e\n\u003ctd\u003eNo hardware jumpers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Configuration\u003c\/td\u003e\n\u003ctd\u003eNo software configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States of America\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePower Supply Function\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCPSG1A receives 125 VDC from the power distribution system and converts it into the voltage levels required by the control system boards. These outputs support different power requirements, including logic circuits, control electronics, and other board-level functions.\u003c\/p\u003e\n\u003cp\u003eEach of the four Mark V cores has a power supply board that converts the incoming 125 VDC supply. Therefore, the TCPS board supports power distribution within its assigned core without requiring software configuration or hardware jumper settings.\u003c\/p\u003e\n\u003ch3\u003eConnector Functions\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCPSG1A uses six identified connectors to receive and distribute power and support system connections.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2PL\u003c\/td\u003e\n\u003ctd\u003eDistributes power supply voltages to multiple boards through a daisy-chain connection.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJ1\u003c\/td\u003e\n\u003ctd\u003eTransfers 125 VDC input power from the TCPD board in the PD core to the TCPS board.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJC\u003c\/td\u003e\n\u003ctd\u003eDistributes power supply voltages for the TCQC board in cores R1, R2, and R3, and the TCCA board in core R5 for power supply diagnostics.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJP1\u003c\/td\u003e\n\u003ctd\u003eDistributes power supply voltages to the AAHA boards in the R core and the TCDA boards in digital cores Q11, Q21, and Q51.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJP2\u003c\/td\u003e\n\u003ctd\u003eProvides the same distribution function as JP1. Either connector can be used.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eX1\u003c\/td\u003e\n\u003ctd\u003eProvides the CCOM bus link.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBoard Configuration and Maintenance\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCPSG1A does not require software configuration or hardware jumper adjustments. This simplifies configuration checks when replacing the board, although the replacement must still match the required part number and system installation.\u003c\/p\u003e\n\u003cp\u003eThe board includes three fuses and several test points for electrical checks. Before replacing a fuse, technicians must disconnect power to the drive and verify that no voltage remains on the board. Depending on the installation and accessibility, technicians may replace the fuses without removing the board from its metal rack. Otherwise, they can remove the four mounting screws to access the board.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the main function of the GE DS200TCPSG1A?\u003c\/p\u003e\n\u003cp\u003eA: The DS200TCPSG1A converts 125 VDC input power from the TCPD board in the PD core into the DC voltage levels required by Mark V control system components.\u003c\/p\u003e\n\u003cp\u003eQ: What output voltages does the DS200TCPSG1A provide?\u003c\/p\u003e\n\u003cp\u003eA: The board provides +5 VDC, +24 VDC, +\/-15 VDC, and +\/-24 VDC outputs for power distribution to connected boards.\u003c\/p\u003e\n\u003cp\u003eQ: Does the DS200TCPSG1A require hardware or software configuration?\u003c\/p\u003e\n\u003cp\u003eA: No. The TCPS board does not use hardware jumpers or software configuration settings.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\" alt=\"GE\" width=\"26\" height=\"25\" style=\"font-size: 0.875rem;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eOther Attributes\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: GE Multilin \u003cstrong\u003e350 Feeder\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eThe GE General Electric Mark VI \u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable height=\"253\" width=\"656\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\" style=\"height: 253px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"222\"\u003e \u003ccol width=\"215\"\u003e \u003ccol width=\"219\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ICBDH1ABB\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210MACCH2AGG\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS220YAICS1AJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS220PPRAH1A\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210AEBIH1BEA\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS220YDIAS1AK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS220UCSAH1A\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ISBEH1ABB\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS220YDOAS1AJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ACLEH1BCB\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TBAIH1CDC\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS420ESWBH3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200EPSMG2AED\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210AEDBH4AGD\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS420UCSCS2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200EROCH1ABC\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200AEADH4ADA\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS410JPDHG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ERIOH1ABC\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200REBFH1BBA\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TBAIS1CED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ERDDH1ABB\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210AEBIH3BED\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TBCIS2CCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200DSPXH1DBD\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS220PCLAH1A\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TRLYS1BGG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS230TRLSH2B\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS420UCSCH1C\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS230TAISH2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS220PDIAH1B\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200DSPXH1DBD\/DSPXH1D\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS230TCISH6C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e    \u003c\/span\u003e\u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"GE General Electric","offers":[{"title":"Default Title","offer_id":68019321176373,"sku":"DS200TCPSG1A","price":333.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/DS200TCPSG1A_Cocoai.jpg?v=1793606102","url":"https:\/\/www.newgenplc.com\/ru\/products\/ge-ds200tcpsg1a-mark-v-power-supply-board","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}