{"product_id":"schneider-electric-c65h-dc-dc-miniature-circuit-breaker","title":"Schneider Electric C65H-DC DC Miniature Circuit Breaker","description":"\u003ch2\u003e\n\u003cimg height=\"25\" width=\"79\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Schneider_480x480.png?v=1697614573\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eConfigured for DC overload and short-circuit protection in low-voltage distribution circuits, the \u003cstrong\u003eSchneider Electric C65H-DC\u003c\/strong\u003e (\u003cstrong\u003eC65H-DC DC Miniature Circuit Breaker\u003c\/strong\u003e) provides direct thermal-magnetic circuit interruption and isolation. The device uses a 2P configuration, supports 250 V DC operation, and provides a 10 kA ultimate breaking capacity.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eC65H-DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDC Miniature Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e6 A to 63 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Curve\u003c\/td\u003e\n\u003ctd\u003eC Curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnetic Trip Characteristic\u003c\/td\u003e\n\u003ctd\u003e8.5 x In +\/- 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltimate Breaking Capacity\u003c\/td\u003e\n\u003ctd\u003e10 kA at 250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Breaking Capacity\u003c\/td\u003e\n\u003ctd\u003e7.5 kA at 250 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd\u003e20,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Durability\u003c\/td\u003e\n\u003ctd\u003e10,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95% at 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e84 mm x 36 mm x 73.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 220 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e1 mm2 to 25 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTightening Torque\u003c\/td\u003e\n\u003ctd\u003e2.5 N m for power circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2, GB 14048.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCCC, IEC CB Report\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDC Thermal-Magnetic Protection Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe C65H-DC uses thermal and magnetic trip functions for DC circuit protection. The thermal element responds to sustained overload current, while the magnetic element responds to high fault current. The specified C Curve magnetic trip characteristic is 8.5 x In +\/- 20%.\u003c\/p\u003e\n\u003cp\u003eThe 2P configuration provides two protected poles. The rated operational voltage is 250 V DC, while the specified ultimate breaking capacity is 10 kA at 250 V DC. The service breaking capacity is 7.5 kA, corresponding to 75% of the specified ultimate breaking capacity.\u003c\/p\u003e\n\u003cp\u003eThe device accepts conductors from 1 mm2 to 25 mm2 through tunnel terminals. Therefore, installers should select conductor size and protection settings according to the connected DC circuit and applicable installation standards.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What DC voltage is specified for the C65H-DC?\u003c\/p\u003e\n\u003cp\u003eA: The rated operational voltage is 250 V DC.\u003c\/p\u003e\n\u003cp\u003eQ: What fault current can the C65H-DC interrupt?\u003c\/p\u003e\n\u003cp\u003eA: The specified ultimate breaking capacity is 10 kA at 250 V DC. The service breaking capacity is 7.5 kA at 250 V DC.\u003c\/p\u003e\n\u003cp\u003eQ: How is the C65H-DC mounted?\u003c\/p\u003e\n\u003cp\u003eA: The circuit breaker uses DIN rail mounting. Its specified dimensions are 84 mm x 36 mm x 73.5 mm.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the C65H-DC on a compatible DIN rail and maintain adequate clearance for terminal access and operating movement. Verify the DC circuit voltage, current rating, polarity, and prospective fault current before energization.\u003c\/p\u003e\n\u003cp\u003eUse conductors within the specified 1 mm2 to 25 mm2 terminal range. Tighten the power-circuit terminals to the specified 2.5 N m torque. Route DC power conductors separately from sensitive signal wiring where practical to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, verify that the selected current rating matches the protected circuit and that the installation complies with IEC 60947-2, GB 14048.2, and applicable local electrical requirements. Confirm correct mechanical operation and secure terminal connections before applying DC power.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Schneider_480x480.png?v=1697614573\" alt=\"\" width=\"79\" height=\"25\" style=\"font-size: 0.875rem;\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSeries：Modicon Quantum \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: \u003cspan\u003e USA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"495\" height=\"95\" style=\"border-collapse: collapse; width: 371.27pt;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"279\" style=\"width: 209.25pt;\"\u003e \u003ccol width=\"216\" style=\"width: 162.00pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd class=\"et5\" height=\"19\" width=\"279\" style=\"height: 14.25pt; width: 209.25pt;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/schneider-140cra93100-rio-networking-module-in-stock-with-factory-sealed?_pos=1\u0026amp;_psq=140CRA93100\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e140CRA93100\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et5\" width=\"216\" style=\"width: 162.00pt;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/schneider-140crp93100-rio-networking-module-in-stock-with-factory-sealed?_pos=1\u0026amp;_psq=140CRP93100\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e140CRP93100\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd class=\"et5\" height=\"19\" style=\"height: 14.25pt;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/schneider-140ddi35300-digital-input-module-in-stock-with-factory-sealed?_pos=1\u0026amp;_psq=140DDI35300\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e140DDI35300\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et5\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/schneider-140nom25200-rio-drop-adaptor-module-in-stock-with-factory-sealed?_pos=1\u0026amp;_psq=140NOM25200\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e140NOM25200\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd class=\"et5\" height=\"19\" style=\"height: 14.25pt;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/schneider-140ddo35300-digital-output-module-in-stock-with-factory-sealed?_pos=1\u0026amp;_psq=140DDO35300\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e140DDO35300\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et5\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/schneider-140aci03000-analog-input-module-in-stock-with-factory-sealed?_pos=1\u0026amp;_psq=140ACI03000\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e140ACI03000\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd class=\"et5\" height=\"19\" style=\"height: 14.25pt;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/schneider-140cps11420-power-supply-module-in-stock-with-factory-sealed?_pos=1\u0026amp;_psq=140CPS11420\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e140CPS11420\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et5\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/schneider-140chs11000-hot-standby-module-in-stock-with-factory-sealed?_pos=1\u0026amp;_psq=140CHS11000\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e140CHS11000\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.25pt;\"\u003e\n\u003ctd class=\"et5\" height=\"19\" style=\"height: 14.25pt;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/schneider-140aco02000-analog-output-module-in-stock-with-factory-sealed?_pos=1\u0026amp;_psq=140ACO02000\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e140ACO02000\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et5\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/schneider-140cpu21304-cpu-controller-in-stock-with-factory-sealed?_pos=1\u0026amp;_psq=140CPU21304\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e140CPU21304\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":53621143044405,"sku":"C65H-DC(IEC60947-2 GB14048.2)","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/C65H-DC_IEC60947-2GB14048_Cocoai.jpg?v=1789971309","url":"https:\/\/www.newgenplc.com\/pt\/products\/schneider-electric-c65h-dc-dc-miniature-circuit-breaker","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}