{"product_id":"rtu560-560cmg10-1kgt017600r0001-abb-communication-unit","title":"RTU560 560CMG10 1KGT017600R0001 | ABB  Communication Unit","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\" alt=\"\" width=\"60\" height=\"25\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch2\u003eABB RTU560 560CMG10 Communication Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB RTU560 560CMG10 (1KGT017600R0001)\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e560CMG10\u003c\/strong\u003e Communication Unit, operates as a dedicated hardware component for data processing and communication management within ABB RTU560 remote terminal unit platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eABB RTU560 560CMG10 (1KGT017600R0001)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 204 mm x 105 mm x 55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 2.8 A at 24 VDC input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Function\u003c\/td\u003e\n\u003ctd\u003eCommunication Unit (CMU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e32-bit MPU, AMD Elan520 or equivalent architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Controller\u003c\/td\u003e\n\u003ctd\u003e8-bit 80C251 type controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e64 MByte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e128 MByte CompactFlash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e10BaseT \/ 100BaseT via RJ45 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Speed\u003c\/td\u003e\n\u003ctd\u003e10 \/ 100 MBit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-232C Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 ports via RJ45 connectors, up to 38,400 bit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRS-485 Interface\u003c\/td\u003e\n\u003ctd\u003e1 port via RJ45 connector, up to 19,200 bit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Bus Interface\u003c\/td\u003e\n\u003ctd\u003ePluggable 20-pole connector with peripheral bus support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Outputs\u003c\/td\u003e\n\u003ctd\u003e5.0 VDC, +\/-15 VDC, 18 VDC, each +\/-5 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe ABB RTU560 560CMG10 manages internal RTU communication through a dedicated peripheral I\/O bus interface. The unit exchanges data with connected I\/O modules through a pluggable 20-pole connector and executes event processing, control command handling, and communication scheduling.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the integrated 32-bit processor architecture and CompactFlash-based storage support system firmware execution and application data management. The communication unit maintains deterministic data exchange between field-level I\/O modules and external SCADA communication networks through Ethernet and serial interfaces.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication interfaces are available on the ABB RTU560 560CMG10?\u003cbr\u003eA: The unit provides one Ethernet interface supporting 10BaseT \/ 100BaseT, two RS-232C serial interfaces, and one RS-485 serial interface.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 560CMG10 provide direct connection to RTU I\/O modules?\u003cbr\u003eA: Yes. The unit connects to peripheral I\/O modules through a pluggable 20-pole I\/O bus connector for internal data exchange.\u003c\/p\u003e\n\u003cp\u003eQ: What power input does the communication unit require?\u003cbr\u003eA: The module operates from a 24 VDC power supply input and generates internal 5.0 VDC, +\/-15 VDC, and 18 VDC outputs for system operation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the ABB RTU560 560CMG10 on the specified DIN-rail mounting structure inside the RTU cabinet.\u003c\/li\u003e\n\u003cli\u003eConnect the 24 VDC power supply using correctly rated industrial wiring and verify polarity before energization.\u003c\/li\u003e\n\u003cli\u003eRoute Ethernet and serial communication cables separately from high-voltage power conductors to reduce electrical interference.\u003c\/li\u003e\n\u003cli\u003eUse shielded communication cables where required and terminate cable shields according to the cabinet grounding design.\u003c\/li\u003e\n\u003cli\u003eVerify RJ45 communication connections and confirm serial interface parameters before system commissioning.\u003c\/li\u003e\n\u003cli\u003eEnsure sufficient cabinet ventilation around the metal housing to maintain operating temperature limits.\u003c\/li\u003e\n\u003cli\u003eCheck firmware compatibility before replacing or upgrading the communication unit within an active RTU560 installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cimg height=\"25\" width=\"60\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Advant DCS\/800xA\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: \u003cspan\u003e \u003c\/span\u003e\u003cspan id=\"dnn_ctr1219_View_LabelCountryOfOrigin\"\u003eGermany\/Sweden\/Finland\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\" alt=\"\" width=\"60\" height=\"25\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof ABB\u003c\/h2\u003e\n\u003ctable width=\"774\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"437\"\u003e3BHB003154R0101 3BHL000389P0104  5SHX2645L0004\u003c\/td\u003e\n\u003ctd width=\"337\"\u003e3BHE02195R0124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE009681R0101 3BHB012961R0001 5SHX2645L0002\u003c\/td\u003e\n\u003ctd\u003eXVC724BE102 3BHE009017R0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE009681R0101 3BHB013088R0001 5SHY3545L0010\u003c\/td\u003e\n\u003ctd\u003eUNS3020 HIEE205010R0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE022333R0101 5SHX0660R0002 5SXE05-0158\u003c\/td\u003e\n\u003ctd\u003e3BHE003855R0001\/UNS 2882A-P,V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB005171R0101 3BHL000986P3105 5SHY3545L0002\u003c\/td\u003e\n\u003ctd\u003e3BHE009319R0001\/UNS 2881B-P,V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101 5SXE10-0181 5SHY6545L0001\u003c\/td\u003e\n\u003ctd\u003e3BHE009949R0002\/UNS 4881B,V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003387R0101 3BHL00385P0101 5SHX0845F0001\u003c\/td\u003e\n\u003ctd\u003e3BHE014967R0002\/UNS 2880B-P,V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003386R0101 3BHL000387P0101 5SHX1445H0002\u003c\/td\u003e\n\u003ctd\u003eUFC765AE102 3BHE003604R0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101\/5SXE10-0181\/5SHY55L4500\u003c\/td\u003e\n\u003ctd\u003eXVC767AE105 3BHB007209R0105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101\/5SXE10-0181\/5SHY55L4520\u003c\/td\u003e\n\u003ctd\u003eXVC768115 3BHB0072R115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003230R0101 3BHL000392P0101 5SHX1060H0001\u003c\/td\u003e\n\u003ctd\u003eXVC768115 3BHB007211R115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003387R0101 3BHL000385P0101 5SHX0845F0001\u003c\/td\u003e\n\u003ctd\u003eAFC094AE02 HIEE200130R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SXE10-0181 5SHY55L4520 AC10272001R0101\u003c\/td\u003e\n\u003ctd\u003eARC093AE01 HIEE300690R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53278717542709,"sku":"RTU560 560CMG10 1KGT017600R0001","price":8888.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/RTU560560CMG101KGT017600R0001_6ece0232-eec3-4ab0-adcc-88f8a9819839.jpg?v=1786613027","url":"https:\/\/www.newgenplc.com\/products\/rtu560-560cmg10-1kgt017600r0001-abb-communication-unit","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}