{"product_id":"fs450r17ke3-agdr-81c-igbt-module-and-gate-driver-assembly-abb","title":"FS450R17KE3 \/ AGDR-81C IGBT Module and Gate Driver Assembly ABB","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\" alt=\"\" width=\"60\" height=\"25\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eConfigured for direct gate control of a 1700 V IGBT power stage, the \u003cstrong\u003eABB FS450R17KE3 \/ AGDR-81C\u003c\/strong\u003e assembly combines the \u003cstrong\u003eFS450R17KE3\u003c\/strong\u003e IGBT module with the \u003cstrong\u003eAGDR-81C\u003c\/strong\u003e gate driver interface for controlled switching in ABB converter hardware. The assembly handles gate-drive signals, isolation, and protection functions at the power semiconductor interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS450R17KE3 \/ AGDR-81C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB \/ Infineon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIGBT Module and Gate Driver Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIGBT Module\u003c\/td\u003e\n\u003ctd\u003eInfineon FS450R17KE3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGate Driver\u003c\/td\u003e\n\u003ctd\u003eABB AGDR-81C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCollector-Emitter Voltage (VCES)\u003c\/td\u003e\n\u003ctd\u003e1700 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Collector Current (IC)\u003c\/td\u003e\n\u003ctd\u003e450 A at TC = 80 deg C; 605 A at TC = 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepetitive Peak Collector Current (ICRM)\u003c\/td\u003e\n\u003ctd\u003e900 A, tp = 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGate-Emitter Voltage (VGES)\u003c\/td\u003e\n\u003ctd\u003e+\/- 20 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Junction Temperature\u003c\/td\u003e\n\u003ctd\u003e150 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Function\u003c\/td\u003e\n\u003ctd\u003eIGBT gate switching and power-stage control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Function\u003c\/td\u003e\n\u003ctd\u003eOptical\/electrical isolation within the gate-driver interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eDesaturation and overcurrent monitoring, as specified for the AGDR-81C interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Drive and Gate-Control Interface\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAGDR-81C\u003c\/strong\u003e controls the IGBT gate interface and separates the control signal from the high-voltage switching stage. Therefore, the driver must match the electrical requirements of the associated \u003cstrong\u003eFS450R17KE3\u003c\/strong\u003e power module.\u003c\/p\u003e\n\u003cp\u003eThe FS450R17KE3 provides a 1700 V collector-emitter voltage rating and a continuous collector current rating of 450 A at a case temperature of 80 deg C. The specified repetitive peak collector current reaches 900 A for a 1 ms pulse.\u003c\/p\u003e\n\u003cp\u003eThe gate interface operates within the stated +\/- 20 V gate-emitter voltage limit. In addition, the supplied data identifies desaturation protection and overcurrent monitoring as driver functions. These functions monitor the switching condition and support controlled response to abnormal collector-current conditions.\u003c\/p\u003e\n\u003cp\u003eFor ABB drive hardware, verify the complete gate-driver, IGBT module, control-board, and power-stage combination before replacement. Do not assume electrical interchangeability from the IGBT module rating alone.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What IGBT module does the AGDR-81C assembly use?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The assembly uses the Infineon FS450R17KE3 IGBT module, rated at 1700 V VCES.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What gate-emitter voltage range does the FS450R17KE3 specify?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied specification states a gate-emitter voltage of +\/- 20 V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the AGDR-81C provide protection functions?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied data identifies desaturation protection and overcurrent monitoring within the gate-driver interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the assembly according to the original ABB converter mechanical arrangement and maintain the specified electrical clearances of the host equipment.\u003c\/p\u003e\n\u003cp\u003eBefore installation, verify the complete part identification, including \u003cstrong\u003eFS450R17KE3\u003c\/strong\u003e and \u003cstrong\u003eAGDR-81C\u003c\/strong\u003e. Check the power terminals, gate connections, auxiliary connections, and mechanical interfaces for damage or contamination.\u003c\/p\u003e\n\u003cp\u003eRoute gate-drive wiring separately from high-current switching conductors where the original equipment design permits. Maintain the existing shielding and grounding arrangement. Do not introduce additional ground paths that can create unwanted switching-current loops.\u003c\/p\u003e\n\u003cp\u003eInspect the IGBT mounting interface and heatsink contact surface before installation. Remove contamination and ensure that the thermal interface follows the equipment manufacturer's specified assembly method.\u003c\/p\u003e\n\u003cp\u003eAfter installation, verify gate-driver connections and control-board interfaces before applying DC-link voltage. Perform insulation, gate-drive, and control checks according to the host converter service procedure.\u003c\/p\u003e\n\u003cp\u003e\u003cimg height=\"25\" width=\"60\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\" style=\"font-size: 0.875rem;\"\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eOther Attributes\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Advant DCS\/800xA\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: \u003cspan\u003e \u003c\/span\u003e\u003cspan id=\"dnn_ctr1219_View_LabelCountryOfOrigin\"\u003eGermany\/Sweden\/Finland\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ABB_480x480.png?v=1697009149\" alt=\"\" width=\"60\" height=\"25\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof ABB\u003c\/h2\u003e\n\u003ctable width=\"774\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"437\"\u003e3BHB003154R0101 3BHL000389P0104  5SHX2645L0004\u003c\/td\u003e\n\u003ctd width=\"337\"\u003e3BHE02195R0124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE009681R0101 3BHB012961R0001 5SHX2645L0002\u003c\/td\u003e\n\u003ctd\u003eXVC724BE102 3BHE009017R0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE009681R0101 3BHB013088R0001 5SHY3545L0010\u003c\/td\u003e\n\u003ctd\u003eUNS3020 HIEE205010R0003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHE022333R0101 5SHX0660R0002 5SXE05-0158\u003c\/td\u003e\n\u003ctd\u003e3BHE003855R0001\/UNS 2882A-P,V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB005171R0101 3BHL000986P3105 5SHY3545L0002\u003c\/td\u003e\n\u003ctd\u003e3BHE009319R0001\/UNS 2881B-P,V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101 5SXE10-0181 5SHY6545L0001\u003c\/td\u003e\n\u003ctd\u003e3BHE009949R0002\/UNS 4881B,V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003387R0101 3BHL00385P0101 5SHX0845F0001\u003c\/td\u003e\n\u003ctd\u003e3BHE014967R0002\/UNS 2880B-P,V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003386R0101 3BHL000387P0101 5SHX1445H0002\u003c\/td\u003e\n\u003ctd\u003eUFC765AE102 3BHE003604R0102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101\/5SXE10-0181\/5SHY55L4500\u003c\/td\u003e\n\u003ctd\u003eXVC767AE105 3BHB007209R0105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC10272001R0101\/5SXE10-0181\/5SHY55L4520\u003c\/td\u003e\n\u003ctd\u003eXVC768115 3BHB0072R115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003230R0101 3BHL000392P0101 5SHX1060H0001\u003c\/td\u003e\n\u003ctd\u003eXVC768115 3BHB007211R115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3BHB003387R0101 3BHL000385P0101 5SHX0845F0001\u003c\/td\u003e\n\u003ctd\u003eAFC094AE02 HIEE200130R0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SXE10-0181 5SHY55L4520 AC10272001R0101\u003c\/td\u003e\n\u003ctd\u003eARC093AE01 HIEE300690R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53616021340469,"sku":"FS450R17KE3\/AGDR-81C","price":8888.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/FS450R17KE3AGDR-81C_Cocoai.jpg?v=1789884051","url":"https:\/\/www.newgenplc.com\/products\/fs450r17ke3-agdr-81c-igbt-module-and-gate-driver-assembly-abb","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}