{"product_id":"yokogawa-anb10d-427-cu2t-esb-bus-node-unit","title":"Yokogawa ANB10D-427\/CU2T ESB Bus Node Unit","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/YOKOGAWA_480x480.png?v=1697472085\" alt=\"\" width=\"70\" height=\"17\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"ybc-p\"\u003e\n\u003cp\u003eThe Yokogawa ANB10D-427\/CU2T is an ESB Bus Node Unit for a dual-redundant ESB bus configuration. It uses a 220-240 V AC dual-redundant power supply and includes a connector unit with terminators for the ESB bus, specified as two S9564FA pieces. The configuration also includes the ISA Standard G3 option without explosion protection, as indicated by the supplied ordering information.\u003c\/p\u003e\n\u003ch3\u003eModel and Suffix Code Configuration\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANB10D\u003c\/td\u003e\n\u003ctd\u003eNode Unit for Dual-Redundant ESB Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-4\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e100-120 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e24 V DC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eBasic type without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option, temperature range option (-20 to +70 deg C), without explosion protection (*1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option, without explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003eBasic type with explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option, temperature range option (-20 to +70 deg C), with explosion protection (*1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eG\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3 option, with explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOption Codes\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOption Code\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003ePart Number \/ Quantity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/CU2N\u003c\/td\u003e\n\u003ctd\u003eConnector Unit for ESB Bus\u003c\/td\u003e\n\u003ctd\u003eS9562FA (2 pieces)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/CU2T\u003c\/td\u003e\n\u003ctd\u003eConnector Unit with Terminator for ESB Bus\u003c\/td\u003e\n\u003ctd\u003eS9564FA (2 pieces)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/ATDOC\u003c\/td\u003e\n\u003ctd\u003eExplosion Protection Manual\u003c\/td\u003e\n\u003ctd\u003eRefer to ordering documentation (*2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/NDEL\u003c\/td\u003e\n\u003ctd\u003eSoftware License for Node Expansion\u003c\/td\u003e\n\u003ctd\u003eRefer to ordering documentation (*3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eANB10D-427\/CU2T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eESB Bus Node Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Configuration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant ESB bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e220-240 V AC, dual-redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e120 VA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003eLess than 20 A peak at power-on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESB Data Rate\u003c\/td\u003e\n\u003ctd\u003e128 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 10 FIO I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Option\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Unit\u003c\/td\u003e\n\u003ctd\u003eESB bus connector unit with terminators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Part Number\u003c\/td\u003e\n\u003ctd\u003eS9564FA, 2 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e48.2 x 22.2 x 5.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.48 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePower Supply and Bus Configuration\u003c\/h3\u003e\n\u003cp\u003eThe ANB10D-427\/CU2T is specified for a dual-redundant ESB bus arrangement with dual-redundant 220-240 V AC power. This configuration identifies the intended power and bus architecture; confirm the system's hardware design and connection requirements before replacing an installed unit.\u003c\/p\u003e\n\u003cp\u003eThe listed typical power consumption is 120 VA, while the stated peak inrush current is less than 20 A at power-on. These values describe different electrical conditions and should be considered separately when checking power distribution capacity.\u003c\/p\u003e\n\u003ch3\u003eESB Bus Termination and Environmental Protection\u003c\/h3\u003e\n\u003cp\u003eThe \/CU2T option specifies a connector unit with terminators for the ESB bus, part number S9564FA, supplied as two pieces according to the provided ordering table. Verify the required termination arrangement against the system connection documentation before installation.\u003c\/p\u003e\n\u003cp\u003eThe suffix code 7 identifies the ISA Standard G3 option without explosion protection in the supplied configuration table. This environmental option does not indicate that the unit is certified for installation in hazardous areas.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power supply does the ANB10D-427\/CU2T use?\u003c\/p\u003e\n\u003cp\u003eA: It is specified for a dual-redundant 220-240 V AC power supply. The listed typical power consumption is 120 VA, with a peak inrush current below 20 A at power-on.\u003c\/p\u003e\n\u003cp\u003eQ: What is included in the CU2T configuration?\u003c\/p\u003e\n\u003cp\u003eA: The supplied ordering information identifies an ESB bus connector unit with terminators, part number S9564FA, in a quantity of two pieces. Confirm the delivered accessories against the purchase order.\u003c\/p\u003e\n\u003cp\u003eQ: Does the ANB10D-427\/CU2T support explosion-protected installations?\u003c\/p\u003e\n\u003cp\u003eA: The supplied suffix table identifies code 7 as the ISA Standard G3 option without explosion protection. Do not treat this configuration as suitable for hazardous-area installation without separate confirmation of the applicable equipment certification.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\n\u003cimg height=\"17\" width=\"70\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/YOKOGAWA_480x480.png?v=1697472085\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCountry of Origin: Japan\/Singapore\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"17\" width=\"70\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/YOKOGAWA_480x480.png?v=1697472085\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof\u003cspan\u003e \u003cu\u003eYOKOGAWA\u003c\/u\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable height=\"471\" width=\"498\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"188\"\u003e \u003ccol width=\"176\"\u003e \u003ccol width=\"134\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd width=\"188\" height=\"23\" class=\"et2\"\u003eANB10D-425\/CU2N\u003c\/td\u003e\n\u003ctd width=\"176\" class=\"et2\"\u003eSDV144-S63\u003c\/td\u003e\n\u003ctd width=\"134\" class=\"et2\"\u003eSAI143-S53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eAAI143-H50\/K4A00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eALE111-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP451-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eEC402-50 S1\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP471-00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSPW482-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eAAI143-H50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP461-51\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-10 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"45\"\u003e\n\u003ctd height=\"45\" class=\"et2\"\u003eSAI143-H63\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-10\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-50 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eAAI143-H50\/A4S00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI533-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eACG10S-F2121 S4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eANB10D-420\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSNT401-53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAIP826-2 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAFF50D-H41201\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eADV161-P50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAV144-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSEC402-51\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAI143-S53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-420\/CU2N\/NDEL\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eANB10D-421\/CU2N\/NDEL\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI143-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eADV151-P53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAAI543-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eDP97-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003ePW484-50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eYNT512D-Q12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eCP345\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAAI143-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-410\/S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAB841-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-420 S2\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eNFCP100-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAF135-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-51\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-10 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAI141-S00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP461-51 S1\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI143-H33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAI141-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP461-51 S2\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI143-H03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAI841-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSNB10D-225\/CU2T\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP345 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAR181-S00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAAI141-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP451-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFDV161-P00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAFV10D-S41211\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003ePW702 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFDV161-P50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-421\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAFV30D-A41452\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAR145-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-425\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eALE111-S50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":67886896152885,"sku":"ANB10D-427\/CU2T","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/ANB10D-427CU2T_Cocoai.jpg?v=1792565620","url":"https:\/\/www.newgenplc.com\/pl\/products\/yokogawa-anb10d-427-cu2t-esb-bus-node-unit","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}