{"product_id":"t8311c-ics-triplex-trusted-tmr-expander-interface-module","title":"T8311C ICS Triplex Trusted TMR Expander Interface Module","description":"\u003ch2\u003e\n\u003cimg style=\"font-size: 0.875rem;\" width=\"75\" src=\"https:\/\/cdn.shopifycdn.net\/s\/files\/1\/0834\/0789\/6885\/files\/ICSTRIPLEX_480x480.png?v=1697217222\" height=\"25\" alt=\"\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eICS Triplex T8311C\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eT8311C\u003c\/strong\u003e Trusted TMR Expander Interface Module, operates as a dedicated hardware component for controller-to-expander communication within the ICS Triplex Trusted system architecture. It manages triplicated expander bus links between controller and expansion chassis interfaces.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eT8311C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICS Triplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTrusted TMR Expander Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.14 kg - 1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 30.3 cm x 3.1 cm x 26.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied from dual redundant nominal 24 V DC backplane feeds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Clocks\u003c\/td\u003e\n\u003ctd\u003e50 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpander Bus Data Rate\u003c\/td\u003e\n\u003ctd\u003e250 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpander-Bus Topology\u003c\/td\u003e\n\u003ctd\u003eTriplicated point-to-point links\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Arrangement\u003c\/td\u003e\n\u003ctd\u003eAdjacent controller I\/O slots; primary module in odd-numbered slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Expansion Connection\u003c\/td\u003e\n\u003ctd\u003eTC-301 through T8312 Expander Interface Adapter arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRemote Expansion Connection\u003c\/td\u003e\n\u003ctd\u003eTC-302 to specified fibre transmitter\/receiver arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Polarization\u003c\/td\u003e\n\u003ctd\u003eKey positions 1, 2 and 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower-Up Operating Mode\u003c\/td\u003e\n\u003ctd\u003eStandby\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Configuration\u003c\/td\u003e\n\u003ctd\u003eNo module-local setup; chassis and slot entry required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTMR Safety Control Architecture\u003c\/h3\u003e\n\u003cp\u003eThe ICS Triplex T8311C uses a triple modular redundant (TMR) hardware arrangement to maintain communication paths between the Trusted controller chassis and expander chassis. The module provides triplicated expander bus connections that support fault containment within the communication interface.\u003c\/p\u003e\n\u003cp\u003eThe module architecture follows SIS design principles used in high-integrity control systems, including redundant signal paths, diagnostic monitoring, and fail-safe state execution. The TMR structure supports 2oo3 voting mechanisms within the Trusted platform architecture to reduce the effect of single-channel hardware faults.\u003c\/p\u003e\n\u003cp\u003eThe conformal-coated construction supports operation in industrial environments where protection against contamination and moisture exposure is required. Galvanic isolation between interface sections helps maintain electrical separation between connected communication paths.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the T8311C require local configuration before installation?\u003cbr\u003eA: No. The module does not include module-local configuration settings. The chassis position and system configuration entry define the operating arrangement.\u003c\/p\u003e\n\u003cp\u003eQ: How does the T8311C connect to expansion chassis?\u003cbr\u003eA: The module connects through the documented Trusted expander interface arrangement. Local expansion uses the TC-301 connection through a T8312 Expander Interface Adapter, while remote expansion uses TC-302 with the specified fibre transmitter\/receiver arrangement.\u003c\/p\u003e\n\u003cp\u003eQ: What power source does the T8311C use?\u003cbr\u003eA: The module receives power from dual redundant nominal 24 V DC backplane feeds within the Trusted chassis.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the T8311C in the designated Trusted controller chassis I\/O slot position according to the system hardware configuration. The primary module position should follow the documented odd-numbered slot arrangement.\u003c\/p\u003e\n\u003cp\u003eVerify that the T8312 Expander Interface Adapter and associated TC-301 or TC-302 connections match the required expansion topology before system startup. Fibre connections used for remote expansion should maintain correct transmitter and receiver pairing.\u003c\/p\u003e\n\u003cp\u003eRoute communication cables separately from high-current power conductors to reduce electrical interference. Maintain proper shield termination and grounding practices according to the cabinet design standards.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, confirm front-panel diagnostic indicators, chassis recognition, and expander bus communication status through the Trusted system diagnostic tools.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg width=\"75\" src=\"https:\/\/cdn.shopifycdn.net\/s\/files\/1\/0834\/0789\/6885\/files\/ICSTRIPLEX_480x480.png?v=1697217222\" height=\"25\" alt=\"\" style=\"font-size: 0.875rem;\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCountry of Origin: \u003cspan\u003e Mexico\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv\u003e\u003cimg width=\"75\" src=\"https:\/\/cdn.shopifycdn.net\/s\/files\/1\/0834\/0789\/6885\/files\/ICSTRIPLEX_480x480.png?v=1697217222\" height=\"25\" alt=\"\"\u003e\u003c\/div\u003e\n\u003ch2\u003e\n\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof ICS TRIPLEX\u003c\/h2\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"320\" height=\"277\" style=\"height: 256.79px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"131\" style=\"width: 202px;\"\u003e \u003ccol width=\"99\" style=\"width: 153px;\"\u003e \u003ccol width=\"90\" style=\"width: 139px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"18\" style=\"height: 19.6023px;\"\u003e\n\u003ctd class=\"et2\" height=\"18\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-do-c5s3-plc-dcs-module-in-stock-100-genuine?_pos=1\u0026amp;_psq=DO-C5S3\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eDO-C5S3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/t8461-ics-triplex-100-genuine-tmr-24-48-vdc-digital-output-module-in-stock?_pos=1\u0026amp;_psq=T8461\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT8461\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/t3511-ics-triplex-tmr-i-o-power-supply-module-in-stock-ready-to-ship?_pos=1\u0026amp;_psq=T3511\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT3511\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 19.6023px;\"\u003e\n\u003ctd class=\"et2\" height=\"18\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-tc-304-01-maintenance-cable-in-stock-100-genuine?_pos=1\u0026amp;_psq=TC-304-01\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eTC-304-01\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/t8403c-ics-triplex-tmr-trusted-digital-input-module-in-stock?_pos=1\u0026amp;_psq=T8403C\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT8403C\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/t9802-ics-triplex-100-brand-new-tmr-analog-input-module-in-stock?_pos=1\u0026amp;_psq=T9802\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT9802\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 21.5625px;\"\u003e\n\u003ctd class=\"et2\" height=\"18\" style=\"height: 21.5625px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t8151b-communications-interface-in-stock-100-brand-new-trusted?_pos=1\u0026amp;_psq=T8151B\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT8151B\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 21.5625px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t9191-blanking-cover-tall-for-i-o-positions-with-no-ta-fitted-in-stock?_pos=1\u0026amp;_psq=T9191\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT9191\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 21.5625px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t8151c-trusted-communications-interface-100-genuine-in-stock?_pos=1\u0026amp;_psq=T8151C\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT8151C\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 19.6023px;\"\u003e\n\u003ctd class=\"et2\" height=\"18\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/t8310-100-genuine-ics-triplex-trusted-expander-processor-in-stock?_pos=1\u0026amp;_psq=T8310\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT8310\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t9193-blanking-cover-short-for-i-o-positions-with-ta-or-a-processor-in-stock?_pos=1\u0026amp;_psq=T9193\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT9193\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/100-brand-new-ics-triplex-t9402-digital-input-module-in-stock?_pos=1\u0026amp;_psq=T9402\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT9402\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 19.6023px;\"\u003e\n\u003ctd class=\"et2\" height=\"18\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t8513-digital-output-module-in-stock-100-genuine?_pos=1\u0026amp;_psq=T8513\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT8513\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t8312-7-trusted-tmr-expander-interface-adapter-unit-in-stock?_pos=1\u0026amp;_psq=T8312\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT8312\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/100-brand-new-ics-triplex-t9451-digital-output-simplex-module-in-stock?_pos=1\u0026amp;_psq=T9451\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT9451\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 19.6023px;\"\u003e\n\u003ctd class=\"et2\" height=\"18\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/100-genuine-ics-triplex-t9100-processor-base-unit-in-stock?_pos=1\u0026amp;_psq=T9100\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT9100\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t8480-trusted-tmr-analogue-output-module-100-genuine-in-stock-with-factory-sealed?_pos=1\u0026amp;_psq=T8480C\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT8480C\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t8300-process-safety-system-plc-module-in-stock?_pos=1\u0026amp;_psq=T8300\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT8300\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 19.6023px;\"\u003e\n\u003ctd class=\"et2\" height=\"18\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/100-genuine-ics-triplex-t9300-i-o-backplane-in-stock?_pos=1\u0026amp;_psq=T9300\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT9300\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/100-brand-new-ics-triplex-t9310-02-expansion-cable-in-stock?_pos=1\u0026amp;_psq=T9310-02\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT9310-02\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t8312-4c-trusted-tmr-expander-processor-in-stock-ready-to-ship?_pos=1\u0026amp;_psq=T8312-4\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT8312-4\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 19.6023px;\"\u003e\n\u003ctd class=\"et2\" height=\"18\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t8100-trusted-tmr-processor-100-genuine-in-stock?_pos=1\u0026amp;_psq=T8100\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT8100\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/t8461-ics-triplex-100-genuine-tmr-24-48-vdc-digital-output-module-in-stock?_pos=1\u0026amp;_psq=T8461C\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT8461C\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t3420a-analog-input-modules-in-stock-100-genuine?_pos=1\u0026amp;_psq=T3420A\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT3420A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 19.6023px;\"\u003e\n\u003ctd class=\"et2\" height=\"18\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t3310-i-o-transceiver-in-stock-100-genuine?_pos=1\u0026amp;_psq=T3310\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT3310\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t8270-module-fan-assembly-for-rack-mounting-in-stock?_pos=1\u0026amp;_psq=T8270\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT8270\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t8191-plc-i-o-communications-module-in-stock?_pos=1\u0026amp;_psq=T8191\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT8191\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 19.6023px;\"\u003e\n\u003ctd class=\"et2\" height=\"18\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/100-genuine-ics-triplex-t9432-analogue-input-simplex-module-in-stock?_pos=1\u0026amp;_psq=T9432\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT9432\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t3481-monitored-guarded-output-modules-in-stock-100-genuine?_pos=1\u0026amp;_psq=T3481\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT3481\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/9300-triconex-tmr-module-brand-new-in-stock?_pos=1\u0026amp;_psq=9300\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e9300\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 19.6023px;\"\u003e\n\u003ctd class=\"et2\" height=\"18\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t8850-expander-interface-module-in-stock-ready-to-ship?_pos=1\u0026amp;_psq=T8850\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT8850\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/100-brand-new-ics-triplex-t9832-analogue-input-termination-assembly-dual-in-stock?_pos=1\u0026amp;_psq=T9832\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT9832\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-9802-module-in-stock-100-genuine?_pos=1\u0026amp;_psq=9802\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e9802\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 19.6023px;\"\u003e\n\u003ctd class=\"et2\" height=\"18\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t9852-digital-output-termination-assembly-dual-in-stock?_pos=1\u0026amp;_psq=T9852\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT9852\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/100-brand-new-ics-triplex-t9110-processor-module-in-stock?_pos=1\u0026amp;_psq=T9110\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT9110\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-9832-board-base-in-stock-100-genuine?_pos=1\u0026amp;_psq=9832\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e9832\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 19.6023px;\"\u003e\n\u003ctd class=\"et2\" height=\"18\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-t3401-24vdc-digital-input-16-ch-in-stock-100-genuine?_pos=1\u0026amp;_psq=T3401\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003eT3401\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-ps01-a-plc-dcs-module-in-stock-100-genuine?_pos=1\u0026amp;_psq=PS01-A\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003ePS01-A\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd class=\"et2\" style=\"height: 19.6023px;\"\u003e\u003ca href=\"https:\/\/www.newgenplc.com\/products\/ics-triplex-9852-board-base-in-stock-100-genuine?_pos=1\u0026amp;_psq=9852\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e9852\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"ICS TRIPLEX","offers":[{"title":"Default Title","offer_id":67694839234869,"sku":"T8311C","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/T8311C-3_1200x1200_Cocoai_f9d9ba8f-8b10-47ad-8985-1cf1c4dccc3b.jpg?v=1791957673","url":"https:\/\/www.newgenplc.com\/pl\/products\/t8311c-ics-triplex-trusted-tmr-expander-interface-module","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}