{"product_id":"honeywell-mu-gaih83-high-level-analog-input-fta","title":"Honeywell MU-GAIH83 High Level Analog Input FTA","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Honeywell_480x480.png?v=1697038586\" alt=\"\" width=\"68\" height=\"13\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell MU-GAIH83 is a High Level Analog Input\/Smart Transmitter Interface (HLAI\/STI) Field Termination Assembly (FTA) designed to connect up to 16 high-level analog signals from conventional and smart transmitters to an associated input\/output processor (IOP). It supports 4-20 mA transmitter signals and provides 1-5 VDC outputs. Furthermore, its dual 50-pin IOP connectors support redundant configurations, while galvanic isolation separates the safe and hazardous sides.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports up to 16 high-level analog input channels.\u003c\/li\u003e\n\u003cli\u003eAccepts 4-20 mA signals from 2-wire and 3-wire transmitters.\u003c\/li\u003e\n\u003cli\u003eProvides 1-5 VDC output signals to the associated HLAI IOP.\u003c\/li\u003e\n\u003cli\u003eDual 50-pin connectors support redundant IOP configurations.\u003c\/li\u003e\n\u003cli\u003eAuxiliary connector supports remote monitoring and alarming.\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation provides 250 VAC separation between safe and hazardous sides.\u003c\/li\u003e\n\u003cli\u003eDesigned for hazardous area applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSignal Interface and Operation\u003c\/h3\u003e\n\u003cp\u003eThe MU-GAIH83 receives 4-20 mA signals from connected transmitters and converts them into corresponding 1-5 VDC signals for the associated HLAI IOP. This signal relationship allows the control system to process transmitter measurements through its analog input interface.\u003c\/p\u003e\n\u003cp\u003eIn addition, the assembly supports both conventional and smart transmitters using 2-wire or 3-wire connections. The auxiliary connector provides an interface for remote monitoring and alarming, while the dual IOP connectors accommodate redundant processor configurations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU-GAIH83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh Level Analog Input \/ Smart Transmitter Interface FTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eHLAI\/STI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003eUp to 16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Types\u003c\/td\u003e\n\u003ctd\u003e2-wire and 3-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e1-5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOP Connectors\u003c\/td\u003e\n\u003ctd\u003eDual 50-pin connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Connector\u003c\/td\u003e\n\u003ctd\u003eRemote monitoring and alarming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.28 A at 24 VDC, with 20 mA signal present at all inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e25.0 W, with 20 mA signal at all inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC between safe and hazardous sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Voltage\u003c\/td\u003e\n\u003ctd\u003e28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e93 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Resistance\u003c\/td\u003e\n\u003ctd\u003e300 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 309 x 124 mm (12 x 4.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFTA Size\u003c\/td\u003e\n\u003ctd\u003eB-size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eElectrical and Safety Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe assembly provides galvanic isolation rated at 250 VAC between the safe and hazardous sides. This separation helps prevent direct electrical coupling between the field wiring and the associated control-side interface.\u003c\/p\u003e\n\u003cp\u003eFor safe selection, the maximum input voltage, current and resistance limits should be considered alongside the connected transmitter specifications. Furthermore, the stated power consumption and dissipation values apply when all input channels carry 20 mA signals.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many analog input channels does the MU-GAIH83 support?\u003c\/p\u003e\n\u003cp\u003eA: The MU-GAIH83 supports up to 16 high-level analog input signals from connected transmitters.\u003c\/p\u003e\n\u003cp\u003eQ: What signal types does the MU-GAIH83 accept and provide?\u003c\/p\u003e\n\u003cp\u003eA: It accepts 4-20 mA signals from 2-wire or 3-wire transmitters and provides corresponding 1-5 VDC signals to the associated HLAI IOP.\u003c\/p\u003e\n\u003cp\u003eQ: Does the MU-GAIH83 support redundant IOP configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes. It features dual 50-pin IOP connectors to support redundant configurations. The specific IOP models and system configuration should be checked before installation.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"13\" width=\"68\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Honeywell_480x480.png?v=1697038586\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Honeywell Experion PKS(C200,C300)\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: \u003cspan\u003e USA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"13\" width=\"68\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Honeywell_480x480.png?v=1697038586\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof Honeywell\u003c\/h2\u003e\n\u003ctable width=\"589\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\"\u003eFC-SDO-1624\u003c\/td\u003e\n\u003ctd width=\"135\"\u003e8C-PAIH51\u003c\/td\u003e\n\u003ctd width=\"268\"\u003eMC-TAMR03 51309218-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-TSDI-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PAIH51*E\u003c\/td\u003e\n\u003ctd\u003eMC-TAOY22 51204172-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-TSDO-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PAIH52\u003c\/td\u003e\n\u003ctd\u003eMU-TMCN02 561401846-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFS-TSAI-1620M\u003c\/td\u003e\n\u003ctd\u003e8C-PAIN01\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH02 51304453-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFS-TSDI-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PAOH51\u003c\/td\u003e\n\u003ctd\u003eMC-TAIL02 51304437-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-RUSIO-3224\u003c\/td\u003e\n\u003ctd\u003e8C-PAON01\u003c\/td\u003e\n\u003ctd\u003eMC-TDID72 51303928-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-SDI-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PCNT01\u003c\/td\u003e\n\u003ctd\u003eMC-TDODI3 51304650-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-BKM-0001\u003c\/td\u003e\n\u003ctd\u003e8C-PDIL51\u003c\/td\u003e\n\u003ctd\u003eMC-TDOY23 51204166-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-IO-0001\u003c\/td\u003e\n\u003ctd\u003e8C-PDILAI\u003c\/td\u003e\n\u003ctd\u003eMU-KLAM06 51304465-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-PSU-UNI2450U\u003c\/td\u003e\n\u003ctd\u003e8C-PDOD51\u003c\/td\u003e\n\u003ctd\u003eMU-TAIH02 51304453-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-QPP-0001\u003c\/td\u003e\n\u003ctd\u003e8C-TAID51\u003c\/td\u003e\n\u003ctd\u003eMU-TAMR03 501309218-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-SAI-1620M\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX51\u003c\/td\u003e\n\u003ctd\u003eMU-TAOX12 51304335-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-USI-0001\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX61\u003c\/td\u003e\n\u003ctd\u003eMU-TDID72 51303928-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-PAOX01\u003c\/td\u003e\n\u003ctd\u003e8C-TAOX61\u003c\/td\u003e\n\u003ctd\u003eMU-TDOD12 51304423-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-PFB801\u003c\/td\u003e\n\u003ctd\u003e8C-TCNT01\u003c\/td\u003e\n\u003ctd\u003eMU-TDOR22 51304427-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-PPIX01\u003c\/td\u003e\n\u003ctd\u003eTC-CCN013\u003c\/td\u003e\n\u003ctd\u003eDC-TFB412 51307618-176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-TAID11\u003c\/td\u003e\n\u003ctd\u003eTC-CCR012\u003c\/td\u003e\n\u003ctd\u003eTK-IOLI01 51403427-175 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC-TAOX11\u003c\/td\u003e\n\u003ctd\u003eTC-IAH161\u003c\/td\u003e\n\u003ctd\u003eTK-PPD011 51309241-175 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC-IDJ161\u003c\/td\u003e\n\u003ctd\u003eTC-OAV081\u003c\/td\u003e\n\u003ctd\u003eTK-PRS021 51404305-275 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC-IXL061\u003c\/td\u003e\n\u003ctd\u003e10300\/1\/1\u003c\/td\u003e\n\u003ctd\u003eCC-TAIX01 51308363-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDCS3000LCN\u003c\/td\u003e\n\u003ctd\u003e51305887-150\u003c\/td\u003e\n\u003ctd\u003e8C-PAOHA1 51454469-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTK-FPDXX2\u003c\/td\u003e\n\u003ctd\u003e10012\/1\/2\u003c\/td\u003e\n\u003ctd\u003e8C-PAIMA1 51454473-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":68197215928629,"sku":"MU-GAIH84","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/MU-GAIH84_Cocoai.jpg?v=1794477862","url":"https:\/\/www.newgenplc.com\/pl\/products\/honeywell-mu-gaih83-high-level-analog-input-fta","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}