{"product_id":"fuji-electric-np1l-as2-as-i-master-module","title":"FUJI Electric NP1L-AS2 AS-i Master Module","description":"\u003ch2\u003e\n\u003cimg height=\"12\" width=\"87\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/FUJI_480x480.png?v=1697555050\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eConfigured for bit-level sensor and actuator communication in an AS-i network, the \u003cstrong\u003eFuji Electric NP1L-AS2\u003c\/strong\u003e (\u003cstrong\u003eNP1L-AS2\u003c\/strong\u003e AS-i Master Module) provides direct physical and electrical execution between the SX bus and connected AS-i slave stations. The module operates with AS-i communication protocol Version 2.1, supports serial half-duplex transmission at 167 kbps, and exchanges cyclic I\/O data with up to 62 slave stations.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNP1L-AS2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFuji Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAS-i Master Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eAS-i Version 2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 180 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eAS-i master section: 30 VDC, 100 mA or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Current Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 100 mA or less, supplied from the SX bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSX Bus Connectable Modules\u003c\/td\u003e\n\u003ctd\u003eMax. 12 units per configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectable Slave Stations\u003c\/td\u003e\n\u003ctd\u003eMax. 62 slaves per master module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Line Format\u003c\/td\u003e\n\u003ctd\u003eTree, line, star, or ring structure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Distance\u003c\/td\u003e\n\u003ctd\u003e100 m total; max. 300 m when using a repeater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Method\u003c\/td\u003e\n\u003ctd\u003eHalf-duplex serial transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e167 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable Cable\u003c\/td\u003e\n\u003ctd\u003eAS-i cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefresh Time\u003c\/td\u003e\n\u003ctd\u003eApprox. 10 ms with 62 connected units; approx. 5 ms with 31 connected units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003eMax. 168\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003eMax. 168\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Data Area\u003c\/td\u003e\n\u003ctd\u003e21 input words \/ 21 output words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAS-i Master Section Supply\u003c\/td\u003e\n\u003ctd\u003eSupplied from the AS-i power supply and insulated from the SX bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAS-i Communication\u003c\/td\u003e\n\u003ctd\u003eAutomatic communication with connected AS-i slave stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Network and I\/O Density Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eNP1L-AS2\u003c\/strong\u003e connects the Fuji Electric SX bus configuration to an AS-i field network for cyclic bit-level communication. Up to 12 modules can be installed within one system configuration according to the specified SX bus capacity.\u003c\/p\u003e\n\u003cp\u003eThe AS-i network supports up to 62 slave stations per master module. These slave devices can include sensors and actuators conforming to AS-i standards. The master controls a maximum of 336 I\/O points, consisting of 168 input points and 168 output points.\u003c\/p\u003e\n\u003cp\u003eIn addition, the module supports tree, line, star, and ring transmission structures. Network cable length is limited to 100 m under the stated configuration. A repeater can extend the maximum transmission distance to 300 m. The master operates at 167 kbps using half-duplex serial transmission.\u003c\/p\u003e\n\u003cp\u003eThe I\/O refresh time depends on the number of connected slave stations. With 62 units connected, the specified refresh time is approximately 10 ms. With 31 units connected, it is approximately 5 ms. This relationship directly affects cyclic field-device update timing.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many AS-i slave stations can the NP1L-AS2 connect?\u003c\/strong\u003e\u003cbr\u003eA: The NP1L-AS2 supports a maximum of 62 AS-i slave stations per master module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many I\/O points can the module control?\u003c\/strong\u003e\u003cbr\u003eA: The module supports up to 336 I\/O points in total, consisting of a maximum of 168 input points and 168 output points.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the AS-i master section electrically connected to the SX bus power supply?\u003c\/strong\u003e\u003cbr\u003eA: The AS-i master section is supplied from the AS-i power supply at 30 VDC and is insulated from the SX bus. The module internal circuitry is supplied from the SX bus at 24 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the \u003cstrong\u003eFuji Electric NP1L-AS2\u003c\/strong\u003e in the specified SX bus system configuration and verify that the total number of connected modules does not exceed the stated maximum of 12 units.\u003c\/p\u003e\n\u003cp\u003eConnect AS-i slave devices using AS-i compliant cable and maintain the applicable network topology and transmission distance. Where a repeater is used, verify the complete network layout and total extended cable distance according to the AS-i installation requirements.\u003c\/p\u003e\n\u003cp\u003eRoute AS-i communication wiring separately from high-power motor and switching conductors where practical. Follow standard industrial grounding and shielding practices for adjacent control equipment to reduce electrical noise coupling.\u003c\/p\u003e\n\u003cp\u003eVerify the AS-i power supply voltage and current capacity before energizing the network. The AS-i master section requires a separate 30 VDC AS-i power supply and remains insulated from the SX bus supply.\u003c\/p\u003e\n\u003cp\u003eAfter installation, confirm slave station addressing, communication status, cyclic I\/O exchange, and system refresh performance before placing connected actuators into operation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/FUJI_480x480.png?v=1697555050\" alt=\"\" width=\"87\" height=\"12\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCountry of Origin: \u003cspan\u003e Germany\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/FUJI_480x480.png?v=1697555050\" alt=\"\" width=\"87\" height=\"12\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eFUJI\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable height=\"180\" width=\"494\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\" style=\"border-collapse: collapse; width: 370.52pt;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"252\" style=\"width: 189.00pt;\"\u003e \u003ccol width=\"242\" style=\"width: 181.50pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd width=\"252\" height=\"18\" class=\"et2\" style=\"height: 13.50pt; width: 189.00pt;\"\u003eNP1PS-245RZ119\u003c\/td\u003e\n\u003ctd width=\"242\" class=\"et2\" style=\"width: 181.50pt;\"\u003eSIS-I2703-LAS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd height=\"18\" class=\"et2\" style=\"height: 13.50pt;\"\u003eNP1W3206U-Z704\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSPC-ATW-FJK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd height=\"18\" class=\"et2\" style=\"height: 13.50pt;\"\u003eNP1W6406T-Z704\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eNC1S-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd height=\"18\" class=\"et2\" style=\"height: 13.50pt;\"\u003eNP1X1606-WZ704\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eNP1L-RS1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd height=\"18\" class=\"et2\" style=\"height: 13.50pt;\"\u003eNP1X6406-WZ704\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eNP1L-RS3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd height=\"18\" class=\"et2\" style=\"height: 13.50pt;\"\u003eNP1Y64T09P1-Z704\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eNP1S-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd height=\"18\" class=\"et2\" style=\"height: 13.50pt;\"\u003eMB-6(PC)\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eNP1L-JS1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd height=\"18\" class=\"et2\" style=\"height: 13.50pt;\"\u003eMC-IO150D\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eNP1L-RS5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd height=\"18\" class=\"et2\" style=\"height: 13.50pt;\"\u003eNJ-CPU-B16\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eNP1PU-048E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\" style=\"height: 13.50pt;\"\u003e\n\u003ctd height=\"18\" class=\"et2\" style=\"height: 13.50pt;\"\u003eNC1Y16T05P5-1\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eNC1B08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"FUJI","offers":[{"title":"Default Title","offer_id":53527852515637,"sku":"NP1L-AS2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/NP1L-AS2_Cocoai.jpg?v=1789033902","url":"https:\/\/www.newgenplc.com\/pl\/products\/fuji-electric-np1l-as2-as-i-master-module","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}