{"product_id":"6es7155-5aa01-0abo-siemens-simatic-et-200mp-profinet-interface-module","title":"6ES7155-5AA01-0ABO | Siemens SIMATIC ET 200MP PROFINET Interface Module","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/SIEMENS_480x480.png?v=1697561613\" alt=\"\" width=\"83\" height=\"16\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eConfigured for PROFINET IO device communication in SIMATIC ET 200MP systems, the \u003cstrong\u003eSiemens 6ES7155-5AA01-0AB0\u003c\/strong\u003e (\u003cstrong\u003eIM 155-5 PN ST\u003c\/strong\u003e PROFINET IO Interface Module) provides direct data exchange between ET 200MP electronic modules and PROFINET controller networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6ES7155-5AA01-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO Device Interface Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC ET 200MP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eWidth: 35 mm; Height: 147 mm; Depth: 129 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003eIM 155-5 PN ST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Functional Status\u003c\/td\u003e\n\u003ctd\u003eFS01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware Version\u003c\/td\u003e\n\u003ctd\u003eV4.1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Function\u003c\/td\u003e\n\u003ctd\u003eIO device interface for ET 200MP electronic modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum IO Modules Without Additional PS\u003c\/td\u003e\n\u003ctd\u003eUp to 12 IO modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum IO Modules With Additional PS\u003c\/td\u003e\n\u003ctd\u003eUp to 30 IO modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShared Device Function\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia Redundancy Protocol (MRP)\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsochronous Real-Time (IRT)\u003c\/td\u003e\n\u003ctd\u003eSupported, minimum cycle time \u0026gt;= 0.25 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFast Startup (FSU)\u003c\/td\u003e\n\u003ctd\u003eSupported, 500 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIdentification Data\u003c\/td\u003e\n\u003ctd\u003eI\u0026amp;M0 to I\u0026amp;M3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngineering Software\u003c\/td\u003e\n\u003ctd\u003eSTEP 7 TIA Portal V14 or higher with HSP 0223; integrated from V15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGSDML Support\u003c\/td\u003e\n\u003ctd\u003eV2.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePROFINET Deterministic Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe Siemens 6ES7155-5AA01-0AB0 provides PROFINET communication processing for SIMATIC ET 200MP stations. The module manages cyclic IO data exchange between the distributed IO station and the PROFINET controller while supporting deterministic network functions.\u003c\/p\u003e\n\u003cp\u003eThe interface module supports PROFINET IRT operation with minimum cycle times down to 0.25 ms. Moreover, Media Redundancy Protocol (MRP) operation allows integration into redundant PROFINET network structures.\u003c\/p\u003e\n\u003cp\u003eThe module supports firmware updates, identification and maintenance data access through I\u0026amp;M0 to I\u0026amp;M3 records, and configuration through STEP 7 engineering environments. The ET 200MP architecture allows I\/O density scaling through additional power supply modules when higher module counts are required.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many ET 200MP IO modules can be connected directly to the 6ES7155-5AA01-0AB0 without an additional power supply module?\u003cbr\u003eA: The interface module supports up to 12 IO modules without an additional PS module. With additional power supply modules, the configuration can support up to 30 IO modules.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 6ES7155-5AA01-0AB0 support PROFINET network redundancy functions?\u003cbr\u003eA: Yes. The module supports Media Redundancy Protocol (MRP) for PROFINET network redundancy configurations.\u003c\/p\u003e\n\u003cp\u003eQ: Which engineering software versions are compatible with this interface module?\u003cbr\u003eA: The module is configurable with STEP 7 TIA Portal V14 or higher using HSP 0223, and it is integrated from TIA Portal V15 or higher.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the IM 155-5 PN ST module on the ET 200MP mounting rail according to the SIMATIC installation specifications. Verify the 24 VDC supply connection polarity before energizing the station.\u003c\/p\u003e\n\u003cp\u003eUse shielded PROFINET cables with proper connector installation and maintain separation between communication wiring and high-voltage power cables. Connect cable shields according to industrial grounding practices to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, confirm the firmware compatibility, GSDML configuration, and PROFINET device parameters within the STEP 7 TIA Portal project. Check module addressing, IO configuration, and network topology before transferring the hardware configuration to the controller.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"16\" width=\"83\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/SIEMENS_480x480.png?v=1697561613\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCountry of Origin: \u003cspan\u003e Germany\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"16\" width=\"83\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/SIEMENS_480x480.png?v=1697561613\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof SIEMENS\u003c\/h2\u003e\n\u003ctable style=\"border-collapse: collapse; width: 433.52pt;\" height=\"342\" width=\"578\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 125.25pt;\" width=\"167\"\u003e \u003ccol style=\"width: 119.25pt;\" width=\"159\"\u003e \u003ccol style=\"width: 189.00pt;\" width=\"252\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt; width: 125.25pt;\" width=\"167\" height=\"18\" class=\"et2\"\u003e6AV6643-0CD01-1AX1\u003c\/td\u003e\n\u003ctd style=\"width: 119.25pt;\" width=\"159\" class=\"et2\"\u003e6DD2920-0AH0\u003c\/td\u003e\n\u003ctd style=\"width: 189.00pt;\" width=\"252\" class=\"et2\"\u003e6ES5324-3UR11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003e6ES7153-2BA02-0XB0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD2920-0AL0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES5948-3UR23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003e6ES7195-1GF30-0XA0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD2920-0BB0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7131-4BF00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003e6ES7195-7DH10-0XA0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e2021828-001\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7132-4BD32-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003e6ES7443-1EX20-0XE0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD1600-0AJ0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7138-4CA01-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003eA1A10000423.00M\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD1601-0AE0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7151-1CA00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003e6ES7972-0BA41-0XA0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD1602-0AE0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7193-4CA40-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003e6AG1307-1EA01-7AA0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD1606-3AC0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7193-4CD20-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003e6ES7414-4HM14-0AB0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD1610-0AG1\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7331-7SF00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003e6ES7972-0BA52-0XA0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD1610-0AK0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7401-2TA01-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003e6ES7317-2EK14-0AB0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD1611-OAFO\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7407-0KA01-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003e6DP1511-8AA\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD1611-OAGO\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7412-2XG00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003e545-1101\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD1662-0AB0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7412-2XJ05-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003e6ES5451-8MA11\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD1662-0AC0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7414-2XG03-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003eAAV11-2 6FQ1517-2A\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD1681-0CB2\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7417-4HT14-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003e6ES7195-7HC00-0XA0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD1688-0AD0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7421-1BL01-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003e6DD2920-0AB1\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD1688-0AE2\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7422-1BL00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003e6DD2920-0AV3\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD1842-0AA0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7452-1AH00-0AE0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 13.50pt;\" height=\"18\"\u003e\n\u003ctd style=\"height: 13.50pt;\" height=\"18\" class=\"et2\"\u003e6DP1210-8BC\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6DD2920-0AA0\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003e6ES7492-1AL00-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53114553303349,"sku":"6ES7155-5AA01-0ABO","price":999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/6ES7155-5AA01-0ABO.jpg?v=1783672172","url":"https:\/\/www.newgenplc.com\/pl\/products\/6es7155-5aa01-0abo-siemens-simatic-et-200mp-profinet-interface-module","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}