{"product_id":"honeywell-mc-pdox02-high-level-digital-output-module","title":"Honeywell MC-PDOX02 High-Level Digital Output Module","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Honeywell_480x480.png?v=1697038586\" alt=\"\" width=\"68\" height=\"13\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eConfigured for digital output signal execution in Honeywell TDC 3000 and Experion PKS PM\/APM subsystems, the \u003cstrong\u003eHoneywell MC-PDOX02-150\u003c\/strong\u003e (\u003cstrong\u003eMC-PDOX02\u003c\/strong\u003e Digital Output Module) provides direct electrical control interface functions between process controllers and field actuators.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-PDOX02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Part Number\u003c\/td\u003e\n\u003ctd\u003e51304487-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Level Digital Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000 \/ Experion PKS Process Manager (PM) and Advanced Process Manager (APM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Function\u003c\/td\u003e\n\u003ctd\u003eDigital output signal control for field devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Interface\u003c\/td\u003e\n\u003ctd\u003eHigh-level digital output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003eTypically 24 VDC or 120 VAC depending on field termination configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between field circuits and internal logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eConformal coating for environmental protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eModule and channel status indication through LED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eHoneywell I\/O chassis rack installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Honeywell I\/O module form factor; exact dimensions not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Output Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe MC-PDOX02 operates as a digital command output interface within Honeywell process control architectures. It receives control states from the processor subsystem and drives external electrical loads through configured field termination assemblies.\u003c\/p\u003e\n\u003cp\u003eThe module supports discrete actuator control applications, including relay coils, solenoid valves, alarm indicators, and motor starter circuits. Additionally, the conformal coating option improves resistance against moisture, dust, and industrial contaminants.\u003c\/p\u003e\n\u003cp\u003eFor Honeywell DCS installations, channel-to-channel isolation and field circuit separation reduce electrical interference between independent output paths. Furthermore, the module architecture supports integration with existing TDC 3000 and Experion PKS I\/O configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the MC-PDOX02 be installed in any Honeywell I\/O chassis slot?\u003cbr\u003eA: The MC-PDOX02 requires a compatible Honeywell PM\/APM I\/O chassis position and matching configuration within the control database. Installation must follow the assigned hardware addressing rules.\u003c\/p\u003e\n\u003cp\u003eQ: Does the MC-PDOX02 provide direct connection to field devices?\u003cbr\u003eA: The module provides digital output processing, while field wiring normally connects through the designated Honeywell field termination assembly or approved interface hardware.\u003c\/p\u003e\n\u003cp\u003eQ: What protection does the -150 suffix provide?\u003cbr\u003eA: The -150 version identifies a conformally coated module configuration designed for environments where additional protection against contaminants is required.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the MC-PDOX02 in the designated Honeywell I\/O chassis location according to system engineering documentation.\u003c\/li\u003e\n\u003cli\u003eVerify module addressing, slot assignment, and control database configuration before commissioning.\u003c\/li\u003e\n\u003cli\u003eUse approved field termination hardware for connection between output channels and external devices.\u003c\/li\u003e\n\u003cli\u003eSeparate digital output wiring from high-voltage power cables to reduce electrical noise coupling.\u003c\/li\u003e\n\u003cli\u003eApply proper shield grounding practices when shielded field cables are used.\u003c\/li\u003e\n\u003cli\u003eConfirm field load ratings before connecting relays, solenoids, or motor starter interfaces.\u003c\/li\u003e\n\u003cli\u003eInspect module seating, connector engagement, and rack locking mechanisms during installation.\u003c\/li\u003e\n\u003cli\u003eFollow Honeywell maintenance procedures for module replacement and system diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"13\" width=\"68\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Honeywell_480x480.png?v=1697038586\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Honeywell Experion PKS(C200,C300)\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: \u003cspan\u003e USA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"13\" width=\"68\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Honeywell_480x480.png?v=1697038586\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof Honeywell\u003c\/h2\u003e\n\u003ctable width=\"589\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\"\u003eFC-SDO-1624\u003c\/td\u003e\n\u003ctd width=\"135\"\u003e8C-PAIH51\u003c\/td\u003e\n\u003ctd width=\"268\"\u003eMC-TAMR03 51309218-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-TSDI-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PAIH51*E\u003c\/td\u003e\n\u003ctd\u003eMC-TAOY22 51204172-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-TSDO-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PAIH52\u003c\/td\u003e\n\u003ctd\u003eMU-TMCN02 561401846-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFS-TSAI-1620M\u003c\/td\u003e\n\u003ctd\u003e8C-PAIN01\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH02 51304453-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFS-TSDI-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PAOH51\u003c\/td\u003e\n\u003ctd\u003eMC-TAIL02 51304437-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-RUSIO-3224\u003c\/td\u003e\n\u003ctd\u003e8C-PAON01\u003c\/td\u003e\n\u003ctd\u003eMC-TDID72 51303928-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-SDI-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PCNT01\u003c\/td\u003e\n\u003ctd\u003eMC-TDODI3 51304650-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-BKM-0001\u003c\/td\u003e\n\u003ctd\u003e8C-PDIL51\u003c\/td\u003e\n\u003ctd\u003eMC-TDOY23 51204166-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-IO-0001\u003c\/td\u003e\n\u003ctd\u003e8C-PDILAI\u003c\/td\u003e\n\u003ctd\u003eMU-KLAM06 51304465-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-PSU-UNI2450U\u003c\/td\u003e\n\u003ctd\u003e8C-PDOD51\u003c\/td\u003e\n\u003ctd\u003eMU-TAIH02 51304453-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-QPP-0001\u003c\/td\u003e\n\u003ctd\u003e8C-TAID51\u003c\/td\u003e\n\u003ctd\u003eMU-TAMR03 501309218-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-SAI-1620M\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX51\u003c\/td\u003e\n\u003ctd\u003eMU-TAOX12 51304335-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-USI-0001\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX61\u003c\/td\u003e\n\u003ctd\u003eMU-TDID72 51303928-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-PAOX01\u003c\/td\u003e\n\u003ctd\u003e8C-TAOX61\u003c\/td\u003e\n\u003ctd\u003eMU-TDOD12 51304423-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-PFB801\u003c\/td\u003e\n\u003ctd\u003e8C-TCNT01\u003c\/td\u003e\n\u003ctd\u003eMU-TDOR22 51304427-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-PPIX01\u003c\/td\u003e\n\u003ctd\u003eTC-CCN013\u003c\/td\u003e\n\u003ctd\u003eDC-TFB412 51307618-176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-TAID11\u003c\/td\u003e\n\u003ctd\u003eTC-CCR012\u003c\/td\u003e\n\u003ctd\u003eTK-IOLI01 51403427-175 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC-TAOX11\u003c\/td\u003e\n\u003ctd\u003eTC-IAH161\u003c\/td\u003e\n\u003ctd\u003eTK-PPD011 51309241-175 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC-IDJ161\u003c\/td\u003e\n\u003ctd\u003eTC-OAV081\u003c\/td\u003e\n\u003ctd\u003eTK-PRS021 51404305-275 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC-IXL061\u003c\/td\u003e\n\u003ctd\u003e10300\/1\/1\u003c\/td\u003e\n\u003ctd\u003eCC-TAIX01 51308363-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDCS3000LCN\u003c\/td\u003e\n\u003ctd\u003e51305887-150\u003c\/td\u003e\n\u003ctd\u003e8C-PAOHA1 51454469-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTK-FPDXX2\u003c\/td\u003e\n\u003ctd\u003e10012\/1\/2\u003c\/td\u003e\n\u003ctd\u003e8C-PAIMA1 51454473-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53247406080309,"sku":"MC-PDOX0251304487-150","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/MC-PDOX0251304487-150.jpg?v=1785825719","url":"https:\/\/www.newgenplc.com\/ms\/products\/honeywell-mc-pdox02-high-level-digital-output-module","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}