{"product_id":"ge-multilin-g60-u04-akh-f8l-h6p-m8n-p6p-u6p-wxx-generator-protection-relay","title":"GE Multilin G60-U04-AKH-F8L-H6P-M8N-P6P-U6P-WXX Generator Protection Relay","description":"\u003ch2\u003e\n\u003cimg height=\"25\" width=\"26\" alt=\"GE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Multilin G60-U04-AKH-F8L-H6P-M8N-P6P-U6P-WXX\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eG60\u003c\/strong\u003e Generator Protection Relay, operates as a dedicated protection hardware component for generator fault detection, measurement, and control execution within the GE Multilin Universal Relay platform.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eG60-U04-AKH-F8L-H6P-M8N-P6P-U6P-WXX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE General Electric (GE Vernova)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eGenerator Protection Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eGE Multilin Universal Relay (UR) Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSynchronous generator protection, control, and monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003eGenerator differential protection, stator ground fault, loss of excitation, reverse power, voltage, and frequency protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eU04 configuration, supports wide-range AC\/DC supply options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput \/ Output Configuration\u003c\/td\u003e\n\u003ctd\u003eAKH, H6P, M8N, P6P configurable protection and control modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eEthernet and serial communication interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eIEC 61850, Modbus RTU\/TCP, DNP 3.0, IEEE C37.118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGE Universal Relay Platform Communication and Control Features\u003c\/h3\u003e\n\u003cp\u003eThe GE Multilin G60 operates on the Universal Relay (UR) modular hardware architecture. The relay processes generator electrical measurements through dedicated analog input circuits and executes protection algorithms through high-speed digital processing.\u003c\/p\u003e\n\u003cp\u003eThe unit supports configurable logic functions for breaker control, alarm generation, trip output operation, and system status monitoring. Furthermore, its communication structure supports IEC 61850 station integration, Modbus data exchange, DNP 3.0 remote monitoring, and IEEE C37.118 synchrophasor data transmission.\u003c\/p\u003e\n\u003cp\u003eThe UR platform supports deterministic industrial networks through Ethernet-based communication. Therefore, the relay can exchange protection information with substation automation systems while maintaining synchronized event records and measurement data.\u003c\/p\u003e\n\u003ch3\u003eFirmware and Industrial Network Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe G60 uses GE Multilin UR firmware architecture for protection logic execution, configuration management, and communication control. Firmware compatibility depends on the installed hardware configuration and factory option codes.\u003c\/p\u003e\n\u003cp\u003eThe relay supports programmable protection settings, configurable input\/output mapping, and logic customization through engineering software tools. In addition, configuration files allow integration with different generator control schemes without changing the physical relay enclosure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the G60-U04-AKH-F8L-H6P-M8N-P6P-U6P-WXX support IEC 61850 communication?\u003cbr\u003eA: Yes. The G60 UR platform supports IEC 61850 communication functions when the corresponding communication option is installed and configured.\u003c\/p\u003e\n\u003cp\u003eQ: Can the G60 hardware configuration be expanded after installation?\u003cbr\u003eA: The UR platform uses modular hardware architecture. Any expansion or replacement must match the original factory configuration and compatible module specifications.\u003c\/p\u003e\n\u003cp\u003eQ: What installation considerations apply to the relay communication wiring?\u003cbr\u003eA: Communication cables should follow industrial practices, including proper shielding, grounding, cable separation from high-voltage conductors, and compliance with site EMC requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the GE Multilin G60 relay in a suitable protection panel with proper mechanical support.\u003c\/li\u003e\n\u003cli\u003eVerify the auxiliary power supply rating before energizing the relay.\u003c\/li\u003e\n\u003cli\u003eConnect generator CT and VT measurement circuits according to approved protection drawings.\u003c\/li\u003e\n\u003cli\u003eMaintain separation between communication wiring and high-current power cables to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eApply shield grounding methods according to the substation grounding design.\u003c\/li\u003e\n\u003cli\u003eVerify firmware version, hardware option codes, and protection settings before commissioning.\u003c\/li\u003e\n\u003cli\u003ePerform input\/output verification tests before connecting the relay to generator trip circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\" alt=\"GE\" width=\"26\" height=\"25\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: GE Multilin \u003cstrong\u003e350 Feeder\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eThe GE General Electric Mark VI \u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable height=\"253\" width=\"656\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\" style=\"height: 253px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"222\"\u003e \u003ccol width=\"215\"\u003e \u003ccol width=\"219\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ICBDH1ABB\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210MACCH2AGG\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS220YAICS1AJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS220PPRAH1A\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210AEBIH1BEA\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS220YDIAS1AK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS220UCSAH1A\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ISBEH1ABB\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS220YDOAS1AJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ACLEH1BCB\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TBAIH1CDC\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS420ESWBH3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200EPSMG2AED\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210AEDBH4AGD\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS420UCSCS2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200EROCH1ABC\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200AEADH4ADA\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS410JPDHG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ERIOH1ABC\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200REBFH1BBA\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TBAIS1CED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ERDDH1ABB\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210AEBIH3BED\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TBCIS2CCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200DSPXH1DBD\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS220PCLAH1A\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TRLYS1BGG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS230TRLSH2B\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS420UCSCH1C\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS230TAISH2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS220PDIAH1B\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200DSPXH1DBD\/DSPXH1D\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS230TCISH6C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e    \u003c\/span\u003e\u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"GE General Electric","offers":[{"title":"Default Title","offer_id":53440107544885,"sku":"G60-U04-AKH-F8L-H6P-M8N-P6P-U6P-WXX","price":333.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/G60-U04-AKH-F8L-H6P-M8N-P6P-U6P-WXX.jpg?v=1788250511","url":"https:\/\/www.newgenplc.com\/ms\/products\/ge-multilin-g60-u04-akh-f8l-h6p-m8n-p6p-u6p-wxx-generator-protection-relay","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}