{"product_id":"ge-is200trlyh1d-mark-vie-relay-output-terminal-board","title":"GE IS200TRLYH1D Mark VIe Relay Output Terminal Board","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\" alt=\"GE\" width=\"26\" height=\"25\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS200TRLYH1D\u003c\/strong\u003e is a Relay Output with Coil Sensing Terminal Board manufactured by General Electric (GE) for the Mark VIe control system. It accommodates 12 plug-in magnetic relays and supports different output configurations, including dry Form-C contacts and external solenoid control. Furthermore, its first six relay circuits provide selectable configurations, while the remaining six provide isolated Form-C contacts for specific output requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IS200TRLYH1D provides relay-based switching between the control system and external field devices. Its 12 relay channels support different output functions, depending on the circuit position and jumper configuration.\u003c\/p\u003e\n\u003cp\u003eThe first six relay circuits can operate as dry Form-C contact outputs or drive external solenoids. Meanwhile, field solenoid power can come from a standard 125 VDC or 115\/230 VAC source, or an optional 24 VDC source. Individual jumper-selectable fuses and onboard suppression support the solenoid power circuits.\u003c\/p\u003e\n\u003cp\u003eRelays 7 through 11 provide unpowered, isolated Form-C contacts. In addition, relay 12 provides an isolated Form-C contact for special applications, such as ignition transformers.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRelay Configuration and Output Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe board uses different relay arrangements to support field switching requirements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelays 1-6:\u003c\/strong\u003e Jumper-selectable dry Form-C contacts or external solenoid drive circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelays 7-11:\u003c\/strong\u003e Unpowered, isolated Form-C contact outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay 12:\u003c\/strong\u003e Isolated Form-C contact for special applications, including ignition transformers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTherefore, users should check the required output function and field power source before selecting the jumper configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200TRLYH1D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRelay Output with Coil Sensing Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Relay Channels\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003ePlug-in Magnetic Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Rated Voltage\u003c\/td\u003e\n\u003ctd\u003e125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs 1-6\u003c\/td\u003e\n\u003ctd\u003eJumper-selectable dry Form-C contacts or solenoid drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs 7-11\u003c\/td\u003e\n\u003ctd\u003eUnpowered, isolated Form-C contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output 12\u003c\/td\u003e\n\u003ctd\u003eIsolated Form-C contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Solenoid Power\u003c\/td\u003e\n\u003ctd\u003e125 VDC, 115\/230 VAC, or optional 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolenoid Circuit Protection\u003c\/td\u003e\n\u003ctd\u003eIndividual jumper-selectable fuses and onboard suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e0-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController and I\/O Module Redundancy\u003c\/td\u003e\n\u003ctd\u003eSimplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Operating System\u003c\/td\u003e\n\u003ctd\u003eQNX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Software\u003c\/td\u003e\n\u003ctd\u003eToolboxST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17.8 cm wide x 33.02 cm high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eGEH-6421M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Configuration and Selection Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IS200TRLYH1D uses ToolboxST for system configuration. Its Simplex designation identifies the stated controller and I\/O module redundancy arrangement. It should not be interpreted as evidence of redundant operation at the individual relay output level.\u003c\/p\u003e\n\u003cp\u003eIn addition, the available field power options differ according to the selected output configuration. For example, the first six circuits can use an external solenoid supply, while the isolated contacts on the remaining channels have different output arrangements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many relay outputs does the IS200TRLYH1D provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides 12 plug-in magnetic relay channels. The first six support jumper-selectable configurations, relays 7-11 provide unpowered isolated Form-C contacts, and relay 12 provides an isolated Form-C contact for special applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the IS200TRLYH1D drive external solenoids?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The first six relay circuits can drive external solenoids. The available field power sources include 125 VDC, 115\/230 VAC, and an optional 24 VDC supply, with individual jumper-selectable fuses and onboard suppression.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What software does the IS200TRLYH1D use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified configuration software is GE ToolboxST. The board is also identified with the QNX internal operating system.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\" alt=\"GE\" width=\"26\" height=\"25\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Mark VI IS200\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003eHot Items \u003c\/span\u003eof \u003cspan\u003eThe GE Speedtronic Mark V\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"656\" height=\"276\" style=\"border-collapse: collapse; width: 492.02pt;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"222\" style=\"width: 166.50pt;\"\u003e \u003ccol width=\"215\" style=\"width: 161.25pt;\"\u003e \u003ccol width=\"219\" style=\"width: 164.25pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCQAG1BFD\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG3AFG\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCCBG1BED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCQCG1BHF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG1AHH\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCCBG3ANE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCQCG1BGK\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG1ACC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200PCCAG2ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCRAG1ACC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG3ADC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCDAH1BHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCTGG1AFF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCEAG1BRE\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCDAH1BHE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200EXPSG1ABB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCEAG1BSF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200DCFBG1BLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200EXPSG1ACB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCEAG1BTF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200PTBAG1AEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200QTBAG1ADC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCCAG1BAA\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200DTBAG1AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TBQBG1ACB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200DTBBG1ABB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCQCG1BKG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TBQAG1ABB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCPSG1AME\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCQAG1BHF-w01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200RTBAG2AHC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCPSG1ARE\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200SDCCG5AHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200SDCCG1AEC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200GDPAG1ALF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200SLCCG3AGH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE General Electric","offers":[{"title":"Default Title","offer_id":68305150411061,"sku":"IS200TRLYH1D","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/IS200TRLYH1D_Cocoai.jpg?v=1794913421","url":"https:\/\/www.newgenplc.com\/lv\/products\/ge-is200trlyh1d-mark-vie-relay-output-terminal-board","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}