{"product_id":"tetc-terminal-block-yokogawa","title":"TETC Terminal Block | Yokogawa","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/YOKOGAWA_480x480.png?v=1697472085\" alt=\"\" width=\"70\" height=\"17\"\u003eProduct Description\u003c\/h2\u003e\n\u003ch2\u003eYokogawa TETC*TETC Terminal Block\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa TETC*TETC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTETC\u003c\/strong\u003e Terminal Block, operates as a dedicated hardware component for field signal termination and electrical routing within Yokogawa DCS I\/O systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTETC*TETC Terminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 390 g (configuration dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive terminal component; no external power consumption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eI\/O Terminal Block \/ Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted or cabinet-mounted installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Type\u003c\/td\u003e\n\u003ctd\u003eScrew terminal connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSignal termination and field wiring interface for Yokogawa control systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eYokogawa DCS Signal Termination Interface\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa TETC terminal block provides physical termination points between field instruments and control system I\/O channels. Therefore, it manages sensor, transmitter, and actuator wiring connections while maintaining organized cabinet installation.\u003c\/p\u003e\n\u003cp\u003eThe terminal structure supports standard industrial wiring practices, including separated signal routing, cable identification, and shield management. In addition, the terminal block configuration depends on the connected Yokogawa I\/O module type and system architecture.\u003c\/p\u003e\n\u003cp\u003eFor Yokogawa process control applications, wiring interfaces commonly support instrumentation signals such as 4-20 mA HART loop connections, FOUNDATION Fieldbus or Profibus PA field communication interfaces when matched with compatible system hardware. Channel-to-channel isolation characteristics depend on the connected I\/O module rather than the passive terminal block itself.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the Yokogawa TETC terminal block process input or output signals internally?\u003c\/strong\u003e\u003cbr\u003eA: No. The TETC is a passive termination component. It provides electrical connection and signal routing between field wiring and Yokogawa I\/O hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the TETC terminal block be replaced without changing the connected I\/O module?\u003c\/strong\u003e\u003cbr\u003eA: Replacement compatibility depends on the specific Yokogawa system configuration, terminal assignment, and cable interface design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the TETC provide electrical isolation between field channels?\u003c\/strong\u003e\u003cbr\u003eA: No. Isolation functions are normally provided by the connected I\/O module or signal conditioning hardware.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the TETC terminal block inside a suitable industrial control cabinet with adequate mechanical support.\u003c\/li\u003e\n\u003cli\u003eVerify terminal assignments before connecting field wiring to prevent incorrect channel mapping.\u003c\/li\u003e\n\u003cli\u003eUse shielded instrumentation cables where required by the signal type and connect cable shields according to the system grounding design.\u003c\/li\u003e\n\u003cli\u003eSeparate low-level analog signal cables from high-voltage power wiring to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConfirm terminal screw tightening conditions during commissioning and maintenance inspections.\u003c\/li\u003e\n\u003cli\u003eMatch the terminal block wiring configuration with the Yokogawa I\/O module documentation before system startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cimg height=\"17\" width=\"70\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/YOKOGAWA_480x480.png?v=1697472085\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCountry of Origin: Japan\/Singapore\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"17\" width=\"70\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/YOKOGAWA_480x480.png?v=1697472085\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof\u003cspan\u003e \u003cu\u003eYOKOGAWA\u003c\/u\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable height=\"471\" width=\"498\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"188\"\u003e \u003ccol width=\"176\"\u003e \u003ccol width=\"134\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd width=\"188\" height=\"23\" class=\"et2\"\u003eANB10D-425\/CU2N\u003c\/td\u003e\n\u003ctd width=\"176\" class=\"et2\"\u003eSDV144-S63\u003c\/td\u003e\n\u003ctd width=\"134\" class=\"et2\"\u003eSAI143-S53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eAAI143-H50\/K4A00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eALE111-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP451-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eEC402-50 S1\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP471-00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSPW482-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eAAI143-H50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP461-51\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-10 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"45\"\u003e\n\u003ctd height=\"45\" class=\"et2\"\u003eSAI143-H63\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-10\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-50 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eAAI143-H50\/A4S00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI533-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eACG10S-F2121 S4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eANB10D-420\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSNT401-53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAIP826-2 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAFF50D-H41201\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eADV161-P50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAV144-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSEC402-51\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAI143-S53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-420\/CU2N\/NDEL\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eANB10D-421\/CU2N\/NDEL\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI143-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eADV151-P53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAAI543-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eDP97-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003ePW484-50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eYNT512D-Q12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eCP345\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAAI143-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-410\/S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAB841-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-420 S2\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eNFCP100-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAF135-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-51\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-10 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAI141-S00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP461-51 S1\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI143-H33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAI141-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP461-51 S2\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI143-H03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAI841-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSNB10D-225\/CU2T\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP345 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAR181-S00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAAI141-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP451-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFDV161-P00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAFV10D-S41211\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003ePW702 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFDV161-P50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-421\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAFV30D-A41452\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAR145-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-425\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eALE111-S50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":53440146473269,"sku":"TETC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/TETC.jpg?v=1788251539","url":"https:\/\/www.newgenplc.com\/it\/products\/tetc-terminal-block-yokogawa","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}