{"product_id":"f3da04-6r-analog-output-module-yokogawa","title":"F3DA04-6R | Analog Output Module | Yokogawa","description":"\u003ch2\u003eYokogawa F3DA04-6R Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa F3DA04-6R\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3DA04\u003c\/strong\u003e analog output module, operates as a dedicated hardware component for precision digital-to-analog signal generation within FA-M3 Range-free Controller systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3DA04-6R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200 mA @ 24 V DC (Inrush: 1 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler\/capacitance coupling (500 V DC withstand)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Speed\u003c\/td\u003e\n\u003ctd\u003e2 us + (2 us x number of channels updated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Ranges\u003c\/td\u003e\n\u003ctd\u003e-10 to 10 V DC, 0 to 10 V DC, 0 to 5 V DC, 1 to 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output Ranges\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC, 0 to 20 mA DC, -20 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1 % FS @ 23+\/-2 deg C; +\/-0.3 % FS @ 0-55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.2 % FS @ 23+\/-2 deg C; +\/-0.3 % FS @ 0-55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Load Resistance\u003c\/td\u003e\n\u003ctd\u003eVoltage: 1 kOhm min; Current: 600 Ohm min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module supports standard 4-20 mA HART loop protocol configurations when interfacing with distributed control systems. While each output channel is isolated from the internal control circuitry via photocoupler and capacitance coupling, individual output channels share a common negative terminal and are not isolated from each other. This design requires careful consideration of grounding schemes to prevent ground loops in multi-drop current loop installations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the module perform simultaneous updates across all four channels?\u003c\/p\u003e\n\u003cp\u003eA: Yes. All active DACs within the same module support synchronous output updates, executing within a single conversion cycle defined by the formula 2 us + (2 us x number of channels).\u003c\/p\u003e\n\u003cp\u003eQ: What is the minimum load requirement for 0-5 V DC voltage output?\u003c\/p\u003e\n\u003cp\u003eA: For 0-5 V DC and 1-5 V DC ranges, the allowable load resistance must be 500 Ohm or higher. For wider ranges such as -10 to 10 V DC, the minimum load is 1 kOhm.\u003c\/p\u003e\n\u003cp\u003eQ: Is external power required for operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module requires an external 24 V DC supply (range: 19.2 to 30 V DC) for powering the output circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module on the designated FA-M3 base unit ensuring proper seating of the backplane connector. Verify that the external 24 V DC supply wiring uses adequately sized conductors to handle the 200 mA nominal current plus inrush conditions. When installing current loop outputs, maintain separation from high-voltage cables to minimize inductive interference. Ensure shield drain wires are terminated at a single point connected to the system ground reference to preserve signal integrity.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":53050580042037,"sku":"F3DA04-6R","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/F3DA04-6R.jpg?v=1782814249","url":"https:\/\/www.newgenplc.com\/it\/products\/f3da04-6r-analog-output-module-yokogawa","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}