{"product_id":"yokogawa-aai135-analog-input-module","title":"Yokogawa AAI135 Analog Input Module","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/YOKOGAWA_480x480.png?v=1697472085\" alt=\"\" width=\"70\" height=\"17\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"ybc-p\"\u003e\n\u003cp\u003eThe AAI135 is an 8-channel analog input module from Yokogawa, designed to receive 4-20 mA DC signals through isolated input channels. It converts field transmitter signals into input data for the control system. Furthermore, the module supports HART communication, allowing digital communication alongside analog signal transmission. Its channel isolation and 10 ms data update period define key characteristics for signal acquisition.\u003c\/p\u003e\n\u003ch3\u003eAnalog Input Function\u003c\/h3\u003e\n\u003cp\u003eThe AAI135 receives 4-20 mA signals from field transmitters through eight isolated input channels. Channel isolation provides electrical separation between input channels and helps limit the propagation of electrical disturbances between signal circuits.\u003c\/p\u003e\n\u003cp\u003eThe module supports a maximum allowable input current of 25 mA. Its input resistance varies with the operating current, while the 500 V AC withstand voltage specification defines the insulation capability between the input and system and between input channels.\u003c\/p\u003e\n\u003ch3\u003eHART Communication\u003c\/h3\u003e\n\u003cp\u003eThe AAI135 supports HART digital communication. This allows compatible field devices to exchange digital information over the 4-20 mA signal loop. Meanwhile, the analog input channel continues to provide the process signal for control system acquisition.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAI135\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of I\/O Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eIsolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Current\u003c\/td\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage (Input to System)\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage (Between Input Channels)\u003c\/td\u003e\n\u003ctd\u003e500 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Power ON)\u003c\/td\u003e\n\u003ctd\u003e290 ohm at 20 mA to 450 ohm at 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Power OFF)\u003c\/td\u003e\n\u003ctd\u003e500 kohm or greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-16 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Power Supply\u003c\/td\u003e\n\u003ctd\u003e15.0 V or higher at 20 mA; 29.3 V or less at 0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e+\/-16 uA per 10 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption (5 VDC)\u003c\/td\u003e\n\u003ctd\u003e360 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption (24 VDC)\u003c\/td\u003e\n\u003ctd\u003e450 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Communication\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal, MIL connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSuffix Code Configuration\u003c\/h3\u003e\n\u003cp\u003eThe AAI135 ordering codes define the communication option, explosion protection and environmental configuration.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSuffix Code\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-S\u003c\/td\u003e\n\u003ctd\u003eStandard type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-H\u003c\/td\u003e\n\u003ctd\u003eWith digital communication (HART protocol)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eWithout explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE\u003c\/td\u003e\n\u003ctd\u003eWith explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eWith ISA Standard G3 option and temperature option (-20 to 70 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eTherefore, the complete ordering code should be checked before replacement or procurement, particularly when HART communication, explosion protection or the ISA Standard G3 option is required.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many analog input channels does the AAI135 provide?\u003c\/p\u003e\n\u003cp\u003eA: The AAI135 provides eight isolated input channels. Each channel accepts a 4-20 mA DC signal.\u003c\/p\u003e\n\u003cp\u003eQ: Does the AAI135 support HART communication?\u003c\/p\u003e\n\u003cp\u003eA: Yes. HART communication is available with the -H suffix configuration. The -S suffix identifies the standard type.\u003c\/p\u003e\n\u003cp\u003eQ: What is the difference between suffix codes 5 and E?\u003c\/p\u003e\n\u003cp\u003eA: Code 5 specifies a configuration without explosion protection, while code E specifies a configuration with explosion protection. Select the appropriate version according to the installation requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\n\u003cimg height=\"17\" width=\"70\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/YOKOGAWA_480x480.png?v=1697472085\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCountry of Origin: Japan\/Singapore\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"17\" width=\"70\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/YOKOGAWA_480x480.png?v=1697472085\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof\u003cspan\u003e \u003cu\u003eYOKOGAWA\u003c\/u\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable height=\"471\" width=\"498\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"188\"\u003e \u003ccol width=\"176\"\u003e \u003ccol width=\"134\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd width=\"188\" height=\"23\" class=\"et2\"\u003eANB10D-425\/CU2N\u003c\/td\u003e\n\u003ctd width=\"176\" class=\"et2\"\u003eSDV144-S63\u003c\/td\u003e\n\u003ctd width=\"134\" class=\"et2\"\u003eSAI143-S53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eAAI143-H50\/K4A00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eALE111-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP451-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eEC402-50 S1\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP471-00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSPW482-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eAAI143-H50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP461-51\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-10 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"45\"\u003e\n\u003ctd height=\"45\" class=\"et2\"\u003eSAI143-H63\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-10\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-50 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eAAI143-H50\/A4S00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI533-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eACG10S-F2121 S4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eANB10D-420\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSNT401-53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAIP826-2 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAFF50D-H41201\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eADV161-P50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAV144-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSEC402-51\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAI143-S53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-420\/CU2N\/NDEL\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eANB10D-421\/CU2N\/NDEL\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI143-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eADV151-P53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAAI543-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eDP97-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003ePW484-50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eYNT512D-Q12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eCP345\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAAI143-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-410\/S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAB841-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-420 S2\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eNFCP100-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAF135-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-51\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-10 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAI141-S00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP461-51 S1\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI143-H33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAI141-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP461-51 S2\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI143-H03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAI841-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSNB10D-225\/CU2T\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP345 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAR181-S00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAAI141-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP451-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFDV161-P00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAFV10D-S41211\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003ePW702 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFDV161-P50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-421\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAFV30D-A41452\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAR145-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-425\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eALE111-S50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":68081376723253,"sku":"AAI135-H53","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/AAI135-H53_Cocoai.jpg?v=1793960056","url":"https:\/\/www.newgenplc.com\/id\/products\/yokogawa-aai135-analog-input-module","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}