{"product_id":"ge-g60-generator-management-relay","title":"GE G60 Generator Management Relay","description":"\u003ch2\u003e\n\u003cimg height=\"25\" width=\"26\" alt=\"GE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE G60-V04-HMH-F8M-H6P-M8M-P6P-U6P-W67\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eG60\u003c\/strong\u003e Generator Management Relay, operates as a dedicated hardware component for synchronous generator protection, control, and interconnection within GE UR-series distribution networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDefinition\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eG60\u003c\/td\u003e\n\u003ctd\u003eGenerator Management Relay, UR family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eV04\u003c\/td\u003e\n\u003ctd\u003eFirmware \/ configuration revision level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003eMounting: Horizontal, 19-inch rack style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM\u003c\/td\u003e\n\u003ctd\u003eFaceplate: English LCD display with keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH\u003c\/td\u003e\n\u003ctd\u003eControl power: 125\/250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eF8M\u003c\/td\u003e\n\u003ctd\u003eCT\/VT module: 8 CT inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eH6P\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O module: 6 Form-A outputs + 4 digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eM8M\u003c\/td\u003e\n\u003ctd\u003eCommunications module: RS485 + 10Base-FL fiber Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP6P\u003c\/td\u003e\n\u003ctd\u003eTransducer \/ auxiliary I\/O module 6P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eU6P\u003c\/td\u003e\n\u003ctd\u003eAdditional I\/O expansion module 6P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eW67\u003c\/td\u003e\n\u003ctd\u003eHarsh-environment coating \/ site option code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eG60-V04-HMH-F8M-H6P-M8M-P6P-U6P-W67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Grid Solutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eCanada \/ USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.8 kg (approximate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e177 mm H x 483 mm W x 254 mm D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e40 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Power\u003c\/td\u003e\n\u003ctd\u003e125\/250 V AC\/DC (88-264 V AC, 90-300 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Inputs\u003c\/td\u003e\n\u003ctd\u003e1 A or 5 A secondary, 0.5-100x In, 4 kV isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e24-300 V wet\/dry, opto-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Contacts\u003c\/td\u003e\n\u003ctd\u003eForm-A\/Form-C, 30 V DC to 250 V AC, 8 A breaking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications Front\u003c\/td\u003e\n\u003ctd\u003eUSB, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications Rear\u003c\/td\u003e\n\u003ctd\u003eDual RS485, 10\/100Base-FX fiber Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\u003ctd\u003e87G, 64G, 40, 59, 81O, 81U, 32R, 50, 51, 46, 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording\u003c\/td\u003e\n\u003ctd\u003e256-cycle waveform capture, 60+ event reports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eIEC 60255, IEEE C37.102, UL 508, CSA, CE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe G60-V04-HMH-F8M-H6P-M8M-P6P-U6P-W67 interfaces with the UR-series backplane bus at deterministic scan rates. Furthermore, the firmware revision V04 dictates flash compatibility boundaries with EnerVista UR Setup configuration software. In addition, the horizontal rack chassis constrains I\/O density scaling across H6P, P6P, and U6P carrier positions. Consequently, slot population must align with the build sheet to prevent address conflicts. Moreover, the W67 coating extends corrosion resistance without altering bus signal integrity.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the G60-V04-HMH-F8M-H6P-M8M-P6P-U6P-W67 accept a firmware upgrade to revision V06?\u003c\/p\u003e\n\u003cp\u003eA: No. The V04 hardware build restricts flash compatibility to V04-level firmware packages. Installing V06 firmware on V04 hardware will corrupt the flash memory and render the unit inoperable.\u003c\/p\u003e\n\u003cp\u003eQ: Does the M8M communications module support hot-swap replacement while the relay is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. The M8M module does not support hot-swap. The control power must be de-energized before removing or inserting the module to prevent backplane arcing and logic solver faults.\u003c\/p\u003e\n\u003cp\u003eQ: What is the redundancy switching delay when dual 125\/250 V AC\/DC supplies are installed?\u003c\/p\u003e\n\u003cp\u003eA: The G60 transitions between redundant supplies in less than 10 ms. Therefore, no protection function dropout occurs during the switchover event.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the relay in a 19-inch horizontal rack enclosure with adequate clearance for heat dissipation. First, verify that the control power is de-energized before installing the unit. Next, torque all CT\/VT terminal connections to manufacturer specifications to prevent loose connections and measurement drift. Additionally, ground the chassis shield to a single-point earth ground using a copper conductor of adequate gauge. Furthermore, separate communication cables from power wiring by a minimum distance of 150 mm to suppress electromagnetic interference. Finally, confirm that the W67 coating remains intact and undamaged during handling, as scratches will compromise the corrosion barrier in harsh environments.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\" alt=\"GE\" width=\"26\" height=\"25\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: GE Multilin \u003cstrong\u003e350 Feeder\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eThe GE General Electric Mark VI \u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable height=\"253\" width=\"656\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\" style=\"height: 253px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"222\"\u003e \u003ccol width=\"215\"\u003e \u003ccol width=\"219\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ICBDH1ABB\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210MACCH2AGG\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS220YAICS1AJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS220PPRAH1A\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210AEBIH1BEA\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS220YDIAS1AK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS220UCSAH1A\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ISBEH1ABB\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS220YDOAS1AJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ACLEH1BCB\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TBAIH1CDC\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS420ESWBH3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200EPSMG2AED\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210AEDBH4AGD\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS420UCSCS2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200EROCH1ABC\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200AEADH4ADA\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS410JPDHG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ERIOH1ABC\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200REBFH1BBA\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TBAIS1CED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ERDDH1ABB\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210AEBIH3BED\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TBCIS2CCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200DSPXH1DBD\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS220PCLAH1A\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TRLYS1BGG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS230TRLSH2B\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS420UCSCH1C\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS230TAISH2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS220PDIAH1B\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200DSPXH1DBD\/DSPXH1D\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS230TCISH6C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e    \u003c\/span\u003e\u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"GE General Electric","offers":[{"title":"Default Title","offer_id":53446635553077,"sku":null,"price":333.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/G60-U04-AKH-F8L-H6P-M8N-P6P-U6P-WXX_29de187b-c035-46a2-8ce8-dde07a646b16.jpg?v=1788347584","url":"https:\/\/www.newgenplc.com\/fr\/products\/ge-g60-generator-management-relay","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}