{"product_id":"pepperl-fuchs-kfd0-hms-163415024-hart-multiplexer-slave-module","title":"Pepperl+Fuchs KFD0-HMS-16(3415024) HART Multiplexer Slave Module","description":"\u003ch2\u003e\n\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/PEPPERLFUCHS.png?v=1716269846\" width=\"35\" height=\"35\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eConfigured for HART signal channel interfacing in the K-System HART multiplexer network, the \u003cstrong\u003ePepperl+Fuchs KFD0-HMS-16(3415024)\u003c\/strong\u003e (\u003cstrong\u003eKFD0-HMS-16\u003c\/strong\u003e HART multiplexer slave module) provides direct physical and electrical execution. The module connects to a KFD2-HMM-16 master through a 14-channel flat cable and handles 16 nonintrinsically safe HART field device signal channels supporting HART revisions 5 to 7.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKFD0-HMS-16(3415024)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eKFD0-HMS-16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003ePepperl+Fuchs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHART Multiplexer Slave Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eK-System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003e16-channel HART signal channel slave interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaster Connection\u003c\/td\u003e\n\u003ctd\u003eKFD2-HMM-16 HART Multiplexer Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Signal Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eNonintrinsically safe HART field device input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported HART Revisions\u003c\/td\u003e\n\u003ctd\u003eRevision 5 to 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Requirement\u003c\/td\u003e\n\u003ctd\u003eNo external power required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Connection\u003c\/td\u003e\n\u003ctd\u003e26-pin flat cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaster-Slave Connection\u003c\/td\u003e\n\u003ctd\u003e14-pin flat cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003eLess than 3 uA at -20 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Terminating Resistor\u003c\/td\u003e\n\u003ctd\u003e230 to 500 ohm standard; up to 1000 ohm possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003eAt least 400 mV peak-to-peak with specified terminating resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e100 ohm or lower, capacitive coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eAccording to HART specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0.08 to 4 V peak-to-peak; typical +\/- 5.2 V local reference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Standard\u003c\/td\u003e\n\u003ctd\u003eEN 61326-1:2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Directive\u003c\/td\u003e\n\u003ctd\u003e2004\/108\/EC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in the provided data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e20 x 93 x 115 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Type\u003c\/td\u003e\n\u003ctd\u003eB1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\/Extended Temperature Data\u003c\/td\u003e\n\u003ctd\u003eLeakage current specified from -20 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNo external power required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN mounting rail according to EN 60715:2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEx Classification\u003c\/td\u003e\n\u003ctd\u003eII 3G Ex nA II T4 X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Safety\u003c\/td\u003e\n\u003ctd\u003eUp to SIL3 according to IEC 61508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDIN-Rail Signal Interface Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe KFD0-HMS-16(3415024) uses a DIN-rail-mounted housing and connects directly with the KFD2-HMM-16 through the specified 14-pin master-slave flat cable. Therefore, the installation does not require a separate external power supply for the slave module.\u003c\/p\u003e\n\u003cp\u003eThe module transfers HART communication signals from 16 field device channels through the analog connection interface. Capacitive output coupling and an output resistance of 100 ohm or lower define the electrical connection behavior.\u003c\/p\u003e\n\u003cp\u003eAlthough this model processes nonintrinsically safe HART channels, the provided application documentation also identifies requirements for installation associated with Ex-area applications. Consequently, the applicable Pepperl+Fuchs statements and declarations of conformity must govern the final installation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the KFD0-HMS-16(3415024) require an external power supply?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The provided specification states that the module requires no external power supply. It operates in connection with the KFD2-HMM-16 HART Multiplexer Master.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which HART field devices can connect to this module?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module accepts nonintrinsically safe HART field device signals and supports HART protocol revisions 5 through 7.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What terminating resistance should be used for the HART output connection?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The standard external terminating resistance range is 230 to 500 ohm. The specification permits values up to 1000 ohm where the application allows this configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the KFD0-HMS-16(3415024) on a 35 mm DIN rail installed according to EN 60715:2001. Maintain adequate cabinet spacing for wiring access and heat dissipation within the specified ambient temperature range.\u003c\/p\u003e\n\u003cp\u003eConnect the analog signal interface through the specified 26-pin flat cable. Then connect the KFD2-HMM-16 master and KFD0-HMS-16 slave interface using the specified 14-pin flat cable. Do not substitute cable pin assignments without verifying the applicable Pepperl+Fuchs documentation.\u003c\/p\u003e\n\u003cp\u003eRoute HART signal wiring separately from high-current switching conductors, motor cables, and other electrical noise sources. Where shielded field wiring is used, apply the shielding arrangement according to the plant grounding design and the applicable HART installation requirements.\u003c\/p\u003e\n\u003cp\u003eInstall the external terminating resistor within the specified electrical range and verify the resulting HART signal level during commissioning. In addition, observe the applicable Statement of Conformity, Declaration of Conformity, Attestation of Conformity, and installation instructions when the assembly is associated with Ex-area applications.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/PEPPERLFUCHS.png?v=1716269846\" width=\"40\" height=\"40\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCountry of Origin: Germany\u003cbr\u003eLead Time:\u0026amp;nbsp;In Stock, 2 Working Days\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"PEPPERL+FUCHS","offers":[{"title":"Default Title","offer_id":53434348732725,"sku":"KFD0-HMS-16(3415024)","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/KFD0-HMS-16_3415024.jpg?v=1788162002","url":"https:\/\/www.newgenplc.com\/fa\/products\/pepperl-fuchs-kfd0-hms-163415024-hart-multiplexer-slave-module","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}