{"product_id":"ds200dspch1ada-ge-turbine-control-lci-card","title":"DS200DSPCH1ADA GE Turbine Control LCI Card","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\" alt=\"GE\" width=\"26\" height=\"25\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe DS200TCQCG1A is an Analog I\/O Expander Board manufactured by General Electric for the Mark V LM gas turbine control system. It scales and conditions additional analog signals received from I\/O core terminal boards, while also providing LVDT and LVDR excitation. Furthermore, the board handles servo output configuration, pulse-rate signal conditioning, and selected generator and turbine measurement signals.\u003c\/p\u003e\n\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCQCG1A (TCQC) processes analog signals from the I\/O core terminal boards before transferring the conditioned signals to other control boards. Its functions include scaling and conditioning mA inputs, pulse-rate signals, liquid fuel flow signals, and high-pressure shaft speed signals.\u003c\/p\u003e\n\u003cp\u003eThe board also provides excitation for LVDT and LVDR transducers. In addition, it supports signal exchange with the STCA and TCQA boards through designated connectors, depending on the signal and installed system configuration.\u003c\/p\u003e\n\u003ch3\u003eSignal Processing and Interfaces\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAnalog signal conditioning: Scales and conditions mA inputs for the megawatt transducer signal before transferring the processed signal to the STCA board through the 19PL connector.\u003c\/li\u003e\n\u003cli\u003ePulse-rate processing: Scales and conditions pulse-rate inputs, including liquid fuel flow and high-pressure shaft speed signals.\u003c\/li\u003e\n\u003cli\u003eTCQA communication: Transfers liquid fuel flow and high-pressure shaft speed signals to the TCQA board through the JE connector in the R1 core.\u003c\/li\u003e\n\u003cli\u003eSTCA signal exchange: Exchanges generator and line signals between the STCA and TCQC boards through the JE connector.\u003c\/li\u003e\n\u003cli\u003eTransducer excitation: Supplies excitation for LVDT and LVDR transducers.\u003c\/li\u003e\n\u003cli\u003eIONET termination: Provides IONET termination when the optional 21\u0026gt; configuration is installed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Configuration\u003c\/h3\u003e\n\u003cp\u003eThe first 16 hardware jumpers determine the servo output current configuration. Odd-numbered jumpers select the source output resistance, while even-numbered jumpers determine feedback scaling.\u003c\/p\u003e\n\u003cp\u003eFor servos 1 through 4, additional feedback scaling options are available through jumpers 25 to 36. These settings support a maximum current range of +\/-240 mA.\u003c\/p\u003e\n\u003cp\u003eOther jumper functions include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBJ17: Designates the RS232 port for card testing.\u003c\/li\u003e\n\u003cli\u003eBJ18 and BJ20: Control the P15 and N15 supplies to proximity transducers.\u003c\/li\u003e\n\u003cli\u003eBJ21: Enables the stall timer.\u003c\/li\u003e\n\u003cli\u003eBJ22: Enables the oscillator for factory testing.\u003c\/li\u003e\n\u003cli\u003eBJ23 and BJ24: Not utilized.\u003c\/li\u003e\n\u003cli\u003eJP38 and JP39: Control magnetic pickup gain for liquid fuel flow signals in certain system configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TCQCG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V LM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog I\/O Expander Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Designation\u003c\/td\u003e\n\u003ctd\u003eTCQC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Signal Processing\u003c\/td\u003e\n\u003ctd\u003eAnalog input scaling and conditioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eServo Output Configuration\u003c\/td\u003e\n\u003ctd\u003eHardware jumper selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Servo Current Range\u003c\/td\u003e\n\u003ctd\u003e+\/-240 mA (servos 1 through 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Excitation\u003c\/td\u003e\n\u003ctd\u003eLVDT and LVDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Transfer Connectors\u003c\/td\u003e\n\u003ctd\u003e19PL, JE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Termination\u003c\/td\u003e\n\u003ctd\u003eIONET termination, subject to optional configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual Reference\u003c\/td\u003e\n\u003ctd\u003eGEH-6153\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eConfiguration and Selection Notes\u003c\/h3\u003e\n\u003cp\u003eThe jumper settings directly affect servo output characteristics, including source output resistance and feedback scaling. Therefore, maintenance personnel should check the installed board configuration against the original system settings before replacement or adjustment.\u003c\/p\u003e\n\u003cp\u003eMeanwhile, JP38 and JP39 require particular attention in systems that use magnetic pickup signals for liquid fuel flow measurement. Their configuration may vary between installations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the DS200TCQCG1A?\u003c\/p\u003e\n\u003cp\u003eA: It scales and conditions analog and pulse-rate signals in the Mark V LM control system. It also provides LVDT and LVDR excitation and supports servo output configuration.\u003c\/p\u003e\n\u003cp\u003eQ: How is the servo output current configured?\u003c\/p\u003e\n\u003cp\u003eA: The first 16 hardware jumpers determine source output resistance and feedback scaling. Jumpers 25 to 36 provide additional feedback scaling options for servos 1 through 4, supporting a maximum current range of +\/-240 mA.\u003c\/p\u003e\n\u003cp\u003eQ: What should be checked when replacing this board?\u003c\/p\u003e\n\u003cp\u003eA: Check the servo jumper settings, transducer supply configuration, magnetic pickup gain settings where applicable, and the required signal connections. These settings should correspond to the original system configuration.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\" alt=\"GE\" width=\"26\" height=\"25\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Mark VI IS200\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003eHot Items \u003c\/span\u003eof \u003cspan\u003eThe GE Speedtronic Mark V\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"656\" height=\"276\" style=\"border-collapse: collapse; width: 492.02pt;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"222\" style=\"width: 166.50pt;\"\u003e \u003ccol width=\"215\" style=\"width: 161.25pt;\"\u003e \u003ccol width=\"219\" style=\"width: 164.25pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCQAG1BFD\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG3AFG\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCCBG1BED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCQCG1BHF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG1AHH\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCCBG3ANE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCQCG1BGK\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG1ACC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200PCCAG2ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCRAG1ACC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG3ADC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCDAH1BHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCTGG1AFF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCEAG1BRE\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCDAH1BHE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200EXPSG1ABB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCEAG1BSF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200DCFBG1BLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200EXPSG1ACB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCEAG1BTF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200PTBAG1AEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200QTBAG1ADC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCCAG1BAA\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200DTBAG1AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TBQBG1ACB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200DTBBG1ABB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCQCG1BKG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TBQAG1ABB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCPSG1AME\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCQAG1BHF-w01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200RTBAG2AHC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCPSG1ARE\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200SDCCG5AHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200SDCCG1AEC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200GDPAG1ALF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200SLCCG3AGH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE General Electric","offers":[{"title":"Default Title","offer_id":68152100421941,"sku":"DS200DSPCH1A","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/DS200DSPCH1A_Cocoai.jpg?v=1794307414","url":"https:\/\/www.newgenplc.com\/es\/products\/ds200dspch1ada-ge-turbine-control-lci-card","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}