{"product_id":"is200erioh1acb-ge-ex2100-exciter-regulator-main-i-o-board","title":"IS200ERIOH1ACB GE EX2100 Exciter Regulator Main I\/O Board","description":"\u003ch2\u003e\n\u003cimg height=\"25\" width=\"26\" alt=\"GE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eConfigured for customer and system I\/O signal interfacing in the GE EX2100 excitation control system, the \u003cstrong\u003eGE IS200ERIOH1ACB\u003c\/strong\u003e (\u003cstrong\u003eIS200ERIOH1A\u003c\/strong\u003e Exciter Regulator Main I\/O Board) provides signal interface connections between the regulator backplane and associated excitation control boards. It supports simplex and redundant configurations and interfaces with the Exciter PT\/CT Terminal Board, Exciter Contact Terminal Board, Dynamic Discharge Board, and Exciter Regulator Options Card.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200ERIOH1ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eIS200ERIOH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX2100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExciter Regulator Main I\/O Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eCustomer and system I\/O signal interfacing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eExcitation regulator control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eSimplex and redundant systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssociated Boards\u003c\/td\u003e\n\u003ctd\u003eEPCT, ECTBG2, ERDD, EROC, ERRR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (provided specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003ePOWER LED, OK LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEX2100 Regulator Backplane and I\/O Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe IS200ERIOH1ACB provides interfaces for customer I\/O signals and internal regulator system signals. Its installation location depends on the excitation system configuration.\u003c\/p\u003e\n\u003cp\u003eIn simplex applications, the board mounts in the Exciter Regulator Backplane (ERBP). It interfaces with customer signals associated with the Exciter PT\/CT Terminal Board (EPCT) and Exciter Contact Terminal Board (ECTBG2). It also interfaces with the Exciter Regulator Dynamic Discharge Board (ERDD) and Exciter Regulator Options Card (EROC).\u003c\/p\u003e\n\u003cp\u003eIn redundant applications, the board is installed in the regulator backplane and the corresponding redundant regulator backplane assembly. The redundant arrangement also supports system signal interfaces associated with the Exciter Regulator Redundant Relay board (ERRR).\u003c\/p\u003e\n\u003cp\u003eThe board's exact channel count, electrical ratings, connector pin assignments, and signal thresholds require confirmation from the applicable GE EX2100 documentation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the function of the IS200ERIOH1ACB in an EX2100 system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It interfaces customer I\/O signals and internal regulator signals with associated excitation control boards. The installation arrangement depends on whether the system uses simplex or redundant control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What do the POWER and OK LEDs indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The POWER LED indicates the board's power status. The OK LED provides a visual indication of board operating status. LED behavior should be checked against the applicable GE troubleshooting documentation before diagnosing a fault.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the IS200ERIOH1ACB be replaced while the excitation system is energized?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Hot replacement capability is not established by the supplied specifications. Confirm the system configuration, isolation requirements, and GE replacement procedure before removing or installing the board.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify the part number.\u003c\/strong\u003e Confirm IS200ERIOH1ACB against the installed board, equipment bill of materials, and applicable EX2100 hardware documentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirm the mounting location.\u003c\/strong\u003e Identify the ERBP or redundant backplane position specified for the installed regulator configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolate the equipment.\u003c\/strong\u003e Follow the site's approved electrical isolation and lockout\/tagout procedures before handling the board. Do not assume the assembly supports energized replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspect the hardware.\u003c\/strong\u003e Check connectors, backplane contacts, board edges, and visible components for damage or contamination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck signal wiring.\u003c\/strong\u003e Verify terminal assignments and cable routing against the system drawings. Keep signal wiring separated from power conductors where required by the installation design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerify grounding and shielding.\u003c\/strong\u003e Follow the GE grounding scheme and site EMC requirements. Avoid introducing unintended shield-ground connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePerform functional checks.\u003c\/strong\u003e After installation, verify the POWER and OK indicators and confirm the expected I\/O behavior using approved commissioning and diagnostic procedures.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\" alt=\"GE\" width=\"26\" height=\"25\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: GE Multilin \u003cstrong\u003e350 Feeder\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eThe GE General Electric Mark VI \u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable height=\"253\" width=\"656\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\" style=\"height: 253px;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"222\"\u003e \u003ccol width=\"215\"\u003e \u003ccol width=\"219\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ICBDH1ABB\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210MACCH2AGG\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS220YAICS1AJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS220PPRAH1A\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210AEBIH1BEA\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS220YDIAS1AK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS220UCSAH1A\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ISBEH1ABB\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS220YDOAS1AJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ACLEH1BCB\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TBAIH1CDC\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS420ESWBH3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200EPSMG2AED\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210AEDBH4AGD\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS420UCSCS2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200EROCH1ABC\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200AEADH4ADA\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS410JPDHG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ERIOH1ABC\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200REBFH1BBA\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TBAIS1CED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200ERDDH1ABB\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS210AEBIH3BED\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TBCIS2CCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS200DSPXH1DBD\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS220PCLAH1A\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS200TRLYS1BGG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS230TRLSH2B\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS420UCSCH1C\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS230TAISH2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 23px;\"\u003e\n\u003ctd width=\"222\" height=\"23\" class=\"et3\" style=\"height: 23px;\"\u003eIS220PDIAH1B\u003c\/td\u003e\n\u003ctd width=\"215\" class=\"et3\" style=\"height: 23px;\"\u003eIS200DSPXH1DBD\/DSPXH1D\u003c\/td\u003e\n\u003ctd width=\"219\" class=\"et3\" style=\"height: 23px;\"\u003eIS230TCISH6C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e    \u003c\/span\u003e\u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"GE General Electric","offers":[{"title":"Default Title","offer_id":67683073065269,"sku":"IS200ERIOH1ACB","price":333.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/IS200ERIOH1ACB-2_Cocoai.jpg?v=1791878016","url":"https:\/\/www.newgenplc.com\/de\/products\/is200erioh1acb-ge-ex2100-exciter-regulator-main-i-o-board","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}