{"product_id":"general-electric-ds200tcqag1a-mark-v-analog-i-o-board","title":"General Electric DS200TCQAG1A Mark V Analog I\/O Board","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\" alt=\"GE\" width=\"26\" height=\"25\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe DS200TCQAG1A is an Analog I\/O Board manufactured by General Electric for the Mark V turbine control system. It scales and conditions analog signals received from terminal boards in the R1, R2, and R3 I\/O cores. The board handles multiple signal types, including thermocouple inputs, 4-20 mA signals, LVDT\/LVDR position feedback, vibration inputs, servo valve outputs, and generator signals.\u003c\/p\u003e\n\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCQAG1A processes analog signals before transferring the conditioned signals to the COREBUS through the 3PL connector. It receives signals from terminal boards and provides the required signal conditioning for the Mark V control system.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the board handles 4-20 mA input signals associated with measurements such as fuel flow, pressure, and compressor stall detection. It also interfaces with servo valve driver outputs, relay driver outputs, pulse signals, and generator and line signals.\u003c\/p\u003e\n\u003ch3\u003eSignal Interfaces and Connectors\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCQAG1A uses multiple connectors to exchange signals and power with other boards and terminal boards.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConnector\u003c\/th\u003e\n\u003cth\u003eFunction\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2PL\u003c\/td\u003e\n\u003ctd\u003eDistributes TCPS board power to the R1, R2, and R3 cores.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3PL\u003c\/td\u003e\n\u003ctd\u003eProvides the data bus connection between the STCA and TCQA boards in R2 and R3, and between the STCA, TCQA, and TCQE boards in R1. Conditioned signals transfer to the COREBUS through this connector.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJA\u003c\/td\u003e\n\u003ctd\u003eCarries thermocouple inputs and cold junction compensation signals from the TBQA terminal board for R1, R2, and R3 cores.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJB\u003c\/td\u003e\n\u003ctd\u003eTransfers 4-20 mA input and output signals through the JBR terminal board connector on the TBQC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJD\u003c\/td\u003e\n\u003ctd\u003eCarries trip signals from the R1 core to the TCTG board in the P1 core. This connector is not used in R2 or R3.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJE\u003c\/td\u003e\n\u003ctd\u003eTransfers servo valve driver outputs, relay driver outputs, generator and line signals, and pulse signals. Power supply monitor inputs are also carried through this interface.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJF\u003c\/td\u003e\n\u003ctd\u003eCarries LVDT\/LVDR position feedback inputs from the JFR terminal board connector on the TBQC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJG\u003c\/td\u003e\n\u003ctd\u003eCarries vibration inputs from the JG terminal board connector on the TBQB, together with +\/-10 VDC inputs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TCQAG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog I\/O Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Designation\u003c\/td\u003e\n\u003ctd\u003eTCQA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eAnalog signal scaling and conditioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Signals\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, thermocouple, vibration, LVDT\/LVDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Signals\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Signal Types\u003c\/td\u003e\n\u003ctd\u003eServo valve driver, relay driver, pulse, generator and line signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Core Compatibility\u003c\/td\u003e\n\u003ctd\u003eR1, R2, R3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOREBUS Interface\u003c\/td\u003e\n\u003ctd\u003e3PL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Distribution Connector\u003c\/td\u003e\n\u003ctd\u003e2PL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e28 x 21.4 x 2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eApplication and Configuration Notes\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCQAG1A performs signal conditioning within the Mark V I\/O architecture. Its connector assignments determine how it exchanges signals with terminal boards and other control boards.\u003c\/p\u003e\n\u003cp\u003eMeanwhile, the JD connector has a specific role in the R1 core and does not serve the same function in R2 or R3. Therefore, maintenance personnel should check the installed I\/O core and connector arrangement before replacing the board.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the main function of the DS200TCQAG1A?\u003c\/p\u003e\n\u003cp\u003eA: It scales and conditions analog signals received from terminal boards and transfers conditioned signals to the COREBUS. It also handles several feedback, control, and monitoring signal types.\u003c\/p\u003e\n\u003cp\u003eQ: Which Mark V I\/O cores use the DS200TCQAG1A?\u003c\/p\u003e\n\u003cp\u003eA: The board is described for use in the R1, R2, and R3 I\/O cores. However, the JD connector is used only in R1 for carrying trip signals to the TCTG board.\u003c\/p\u003e\n\u003cp\u003eQ: What is the difference between the JA, JB, and JG connectors?\u003c\/p\u003e\n\u003cp\u003eA: JA carries thermocouple inputs and cold junction compensation signals. JB handles 4-20 mA signals, while JG carries vibration inputs and +\/-10 VDC signals.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\" alt=\"GE\" width=\"26\" height=\"25\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Mark VI IS200\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003eHot Items \u003c\/span\u003eof \u003cspan\u003eThe GE Speedtronic Mark V\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"656\" height=\"276\" style=\"border-collapse: collapse; width: 492.02pt;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"222\" style=\"width: 166.50pt;\"\u003e \u003ccol width=\"215\" style=\"width: 161.25pt;\"\u003e \u003ccol width=\"219\" style=\"width: 164.25pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCQAG1BFD\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG3AFG\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCCBG1BED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCQCG1BHF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG1AHH\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCCBG3ANE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCQCG1BGK\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG1ACC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200PCCAG2ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCRAG1ACC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG3ADC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCDAH1BHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCTGG1AFF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCEAG1BRE\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCDAH1BHE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200EXPSG1ABB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCEAG1BSF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200DCFBG1BLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200EXPSG1ACB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCEAG1BTF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200PTBAG1AEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200QTBAG1ADC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCCAG1BAA\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200DTBAG1AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TBQBG1ACB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200DTBBG1ABB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCQCG1BKG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TBQAG1ABB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCPSG1AME\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCQAG1BHF-w01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200RTBAG2AHC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCPSG1ARE\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200SDCCG5AHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200SDCCG1AEC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200GDPAG1ALF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200SLCCG3AGH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE General Electric","offers":[{"title":"Default Title","offer_id":68152361091381,"sku":"DS200TCQAG1A","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/DS200TCQAG1A_Cocoai.jpg?v=1794307747","url":"https:\/\/www.newgenplc.com\/de\/products\/general-electric-ds200tcqag1a-mark-v-analog-i-o-board","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}