{"product_id":"meggitt-iqs450204-450-000-001-a2-b12-h10-i1-iqs450-proximity-signal-conditioner","title":"Meggitt IQS450204-450-000-001-A2-B12-H10-I1 IQS450 Proximity Signal Conditioner","description":"\u003ch2\u003e\n\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/OIP_1_c57bf544-f1cb-4df2-b310-7e3090e3faa8.png?v=1730961514\" width=\"76\" height=\"14\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eConfigured for proximity signal conditioning in the Vibro-Meter proximity measurement system, the \u003cstrong\u003eMeggitt IQS450204-450-000-001-A2-B12-H10-I1\u003c\/strong\u003e (\u003cstrong\u003eIQS450\u003c\/strong\u003e Proximity Signal Conditioner) provides direct electrical signal conversion between compatible TQ series proximity transducers and downstream monitoring equipment. It conditions eddy-current sensor signals into standardized voltage or current outputs while maintaining compatibility with EA series extension cables. The supplied \u003cstrong\u003eI1\u003c\/strong\u003e configuration includes the MA130 DIN rail mounting adaptor for cabinet installation.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe ordering code \u003cstrong\u003eIQS450204-450-000-001-A2-B12-H10-I1\u003c\/strong\u003e represents a factory-defined configuration. The available documentation confirms the following:\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSuffix\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eA2-B12-H10-I1\u003c\/td\u003e\n\u003ctd\u003eFactory configuration including hazardous-area version, sensitivity, total system length, and MA130 DIN rail mounting adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI1\u003c\/td\u003e\n\u003ctd\u003eMA130 DIN rail mounting adaptor supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe manufacturer does not publicly define every individual suffix element in the ordering code. Therefore, detailed decoding of \u003cstrong\u003eA2\u003c\/strong\u003e, \u003cstrong\u003eB12\u003c\/strong\u003e, and \u003cstrong\u003eH10\u003c\/strong\u003e should be verified using the official Meggitt Vibro-Meter ordering guide.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIQS450204-450-000-001-A2-B12-H10-I1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eIQS450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eMeggitt Vibro-Meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSwitzerland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity Signal Conditioner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Sensors\u003c\/td\u003e\n\u003ctd\u003eTQ Series proximity transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Extension Cable\u003c\/td\u003e\n\u003ctd\u003eEA Series extension cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eEddy-current proximity measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003e3-wire voltage output or 2-wire current output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e-20 VDC to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output\u003c\/td\u003e\n\u003ctd\u003e-1.6 V to -17.6 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output\u003c\/td\u003e\n\u003ctd\u003e15.5 mA to 20.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Range\u003c\/td\u003e\n\u003ctd\u003e16 V (voltage), 5 mA (current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e500 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003eSelf-locking miniature coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connection\u003c\/td\u003e\n\u003ctd\u003eThree screw terminals, up to 2.5 mm2 conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eMaximum 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eInjection-moulded aluminium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eMA130 DIN rail adaptor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 140 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Measurements\u003c\/td\u003e\n\u003ctd\u003eShaft vibration, axial displacement, shaft position, eccentricity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Signal Performance\u003c\/h3\u003e\n\u003cp\u003eThe IQS450 operates as part of the Vibro-Meter eddy-current proximity measurement chain. It works together with compatible \u003cstrong\u003eTQ\u003c\/strong\u003e proximity probes and \u003cstrong\u003eEA\u003c\/strong\u003e extension cables that are calibrated as a complete measurement system. Consequently, replacing only one component without maintaining the specified measurement chain can affect scaling accuracy.\u003c\/p\u003e\n\u003cp\u003eThe conditioner continuously converts the probe's high-frequency impedance variation into a conditioned analog output. As a result, machinery protection systems and monitoring platforms receive a stable electrical representation of shaft movement. Furthermore, proper probe installation and gap adjustment allow verification of the operating point before dynamic vibration measurements begin. Correct sensor calibration also supports rotor dynamics analysis while reducing unwanted signal cross-talk between adjacent measurement channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the IQS450 be used with proximity probes from other manufacturers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The IQS450 is designed for operation with compatible Vibro-Meter TQ series proximity transducers and EA series extension cables. Mixing components from different measurement systems can change calibration characteristics and measurement accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the IQS450 support hot replacement while the monitoring system remains energized?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The available product documentation does not specify hot-swap capability. Follow plant maintenance procedures and isolate the associated measurement channel before replacing the signal conditioner.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why should the probe, extension cable, and signal conditioner remain as one calibrated system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The eddy-current measurement chain is factory calibrated as a complete assembly. Maintaining the specified combination preserves sensitivity, linearity, and output scaling throughout the measurement range.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the IQS450 securely on the supplied MA130 DIN rail adaptor inside a suitable industrial enclosure.\u003c\/li\u003e\n\u003cli\u003eRoute proximity probe cables separately from high-power motor and inverter wiring to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eMaintain cable shielding according to the Vibro-Meter installation manual, and terminate the shield using the recommended grounding practice.\u003c\/li\u003e\n\u003cli\u003eTighten terminal connections according to the manufacturer's instructions to prevent intermittent electrical contact.\u003c\/li\u003e\n\u003cli\u003eVerify the complete TQ probe, EA extension cable, and IQS450 measurement chain before commissioning the monitoring system.\u003c\/li\u003e\n\u003cli\u003eConfirm supply polarity before energizing the module because incorrect wiring can prevent proper signal conditioning.\u003c\/li\u003e\n\u003cli\u003eAfter installation, validate the analog output against the configured monitoring channel before placing rotating machinery into service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/OIP_1_c57bf544-f1cb-4df2-b310-7e3090e3faa8.png?v=1730961514\" width=\"76\" height=\"14\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCountry of Origin: USA\u003cbr\u003eLead Time:\u0026amp;nbsp;In Stock, 2 Working Days\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cspan style=\"font-size: 0.875rem;\"\u003eOur Competitive Brands\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"MEGGITT","offers":[{"title":"Default Title","offer_id":53258458825013,"sku":"IQS450204-450-000-001-A2-B12-H10-I1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/IQS450204-450-000-001-A2-B12-H10-I1_100a37f4-c098-4509-b3bc-b23772cbe0ec.jpg?v=1786097561","url":"https:\/\/www.newgenplc.com\/bg\/products\/meggitt-iqs450204-450-000-001-a2-b12-h10-i1-iqs450-proximity-signal-conditioner","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}