{"product_id":"ge-is200gdddg1aba-ex2000-gate-driver-and-dynamic-discharge-board","title":"GE IS200GDDDG1ABA EX2000 Gate Driver and Dynamic Discharge Board","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\" alt=\"GE\" width=\"26\" height=\"25\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS200GDDDG1ABA\u003c\/strong\u003e is a Gate Driver and Dynamic Discharge Board manufactured by General Electric (GE) for the EX2000 series. It provides electrical isolation between the IGBT devices and the primary processor firing circuits in GE's PWM-based excitation system. Furthermore, the board controls dynamic discharge switching and processes key electrical and thermal feedback signals for transmission to the LDCC processors.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IS200GDDDG1ABA provides an interface between the IGBT power switching devices and the primary processor firing circuits. Its isolation function separates the power switching stage from the control electronics, helping prevent electrical interference from affecting the firing signals.\u003c\/p\u003e\n\u003cp\u003eMeanwhile, the board manages the dynamic discharge circuitry within the EX2000 PWM exciter. It controls the gating circuits for the active IGBTs in both the A and B legs, regulating their activation and deactivation during dynamic discharge operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDynamic Discharge and IGBT Control\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe dynamic discharge circuit manages the discharge process within the excitation system. The IS200GDDDG1ABA controls the associated IGBT gating circuits for both A and B legs. This allows the control system to coordinate switching operations during the discharge process.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstrumentation and Signal Processing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIn addition to gate control and electrical isolation, the board processes several measurement signals used by the EX2000 PWM system:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOutput DC voltage\u003c\/li\u003e\n\u003cli\u003eDC link voltage\u003c\/li\u003e\n\u003cli\u003eShunt current through a millivolt-level input\u003c\/li\u003e\n\u003cli\u003eHeat sink temperature through a thermistor input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe board transmits these processed measurement signals to the LDCC processors. The regulators then use this feedback for voltage and current regulation and system control.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200GDDDG1ABA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eGate Driver and Dynamic Discharge Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Function\u003c\/td\u003e\n\u003ctd\u003eIGBT gate control, dynamic discharge control and signal processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIGBT Control\u003c\/td\u003e\n\u003ctd\u003eA and B legs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Function\u003c\/td\u003e\n\u003ctd\u003eInterface isolation between IGBTs and primary processor firing circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Inputs\u003c\/td\u003e\n\u003ctd\u003eOutput DC voltage, DC link voltage, shunt current and heat sink thermistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Destination\u003c\/td\u003e\n\u003ctd\u003eLDCC processors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e17.8 cm high x 33.02 cm wide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the main function of the GE IS200GDDDG1ABA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides IGBT gate drive interface isolation, controls the dynamic discharge circuitry and processes electrical and thermal feedback signals in the EX2000 PWM exciter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which IGBT circuits does this board control?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It controls the gating circuits for the active IGBTs in both the A and B legs of the dynamic discharge circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What measurement signals does the IS200GDDDG1ABA process?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It processes output DC voltage, DC link voltage, shunt current millivolt input and heat sink thermistor data. It then sends the processed signals to the LDCC processors for regulator use.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/GE_480x480.png?v=1696902574\" alt=\"GE\" width=\"26\" height=\"25\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Mark VI IS200\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: USA\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan style=\"color: #ff2a00;\"\u003eHot Items \u003c\/span\u003eof \u003cspan\u003eThe GE Speedtronic Mark V\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"656\" height=\"276\" style=\"border-collapse: collapse; width: 492.02pt;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"222\" style=\"width: 166.50pt;\"\u003e \u003ccol width=\"215\" style=\"width: 161.25pt;\"\u003e \u003ccol width=\"219\" style=\"width: 164.25pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCQAG1BFD\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG3AFG\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCCBG1BED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCQCG1BHF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG1AHH\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCCBG3ANE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCQCG1BGK\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG1ACC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200PCCAG2ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCRAG1ACC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200SLCCG3ADC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCDAH1BHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TCTGG1AFF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCEAG1BRE\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCDAH1BHE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200EXPSG1ABB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCEAG1BSF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200DCFBG1BLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200EXPSG1ACB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCEAG1BTF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200PTBAG1AEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200QTBAG1ADC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCCAG1BAA\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200DTBAG1AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TBQBG1ACB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200DTBBG1ABB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCQCG1BKG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200TBQAG1ABB\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCPSG1AME\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200TCQAG1BHF-w01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200RTBAG2AHC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200TCPSG1ARE\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200SDCCG5AHD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\" style=\"height: 17.25pt;\"\u003e\n\u003ctd class=\"et3\" height=\"23\" width=\"222\" style=\"height: 17.25pt; width: 166.50pt;\"\u003eDS200SDCCG1AEC\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"215\" style=\"width: 161.25pt;\"\u003eDS200GDPAG1ALF\u003c\/td\u003e\n\u003ctd class=\"et3\" width=\"219\" style=\"width: 164.25pt;\"\u003eDS200SLCCG3AGH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE General Electric","offers":[{"title":"Default Title","offer_id":68489299722549,"sku":"IS200GDDDG1ABA","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/IS200GDDDG1ABA_Cocoai.jpg?v=1795604024","url":"https:\/\/www.newgenplc.com\/bg\/products\/ge-is200gdddg1aba-ex2000-gate-driver-and-dynamic-discharge-board","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}