{"product_id":"yokogawa-aai841-h50-analog-i-o-module","title":"YOKOGAWA AAI841-H50 Analog I\/O Module","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/YOKOGAWA_480x480.png?v=1697472085\" alt=\"\" width=\"70\" height=\"17\"\u003eProduct Description\u003c\/h2\u003e\n\u003cdiv class=\"ybc-p\"\u003e\n\u003cp\u003eThe YOKOGAWA AAI841-H50 is an analog I\/O module that provides 8-channel input and 8-channel output for 4-20 mA signals. It supports non-isolated channel configuration and HART digital communication. Furthermore, the module provides configurable 2-wire or 4-wire transmitter connections, allowing each channel to accommodate the selected transmitter wiring arrangement.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8-channel analog input and 8-channel analog output.\u003c\/li\u003e\n\u003cli\u003eSupports 4-20 mA input and output signals.\u003c\/li\u003e\n\u003cli\u003eNon-isolated I\/O channel configuration.\u003c\/li\u003e\n\u003cli\u003eHART digital communication support.\u003c\/li\u003e\n\u003cli\u003ePer-channel selection of 2-wire or 4-wire transmitter connections using setting pins.\u003c\/li\u003e\n\u003cli\u003e10 ms data update period.\u003c\/li\u003e\n\u003cli\u003eSeparate input and output step response times.\u003c\/li\u003e\n\u003cli\u003ePressure clamp terminal and KS cable external connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAI841-H50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eNon-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Current\u003c\/td\u003e\n\u003ctd\u003e25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Power ON)\u003c\/td\u003e\n\u003ctd\u003e400 ohm at 20 mA to 1000 ohm at 4 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance (Power OFF)\u003c\/td\u003e\n\u003ctd\u003e500 kohm or larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Load Resistance\u003c\/td\u003e\n\u003ctd\u003e0-750 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit-Open Detection\u003c\/td\u003e\n\u003ctd\u003eLess than 0.65 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-16 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-48 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Step Response Time\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Step Response Time\u003c\/td\u003e\n\u003ctd\u003e40 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Power Supply\u003c\/td\u003e\n\u003ctd\u003e14.8 V or higher at 20 mA; 26.4 V or less at 0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Configuration\u003c\/td\u003e\n\u003ctd\u003e2-wire or 4-wire, selectable per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% per 10 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption (5 VDC)\u003c\/td\u003e\n\u003ctd\u003e310 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Consumption (24 VDC)\u003c\/td\u003e\n\u003ctd\u003e500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Communication\u003c\/td\u003e\n\u003ctd\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal, KS cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eAnalog Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe AAI841-H50 handles both analog input and output signals within one module. Its 8 input channels receive 4-20 mA signals from field devices, while the 8 output channels transmit 4-20 mA control signals to external equipment. Therefore, it supports both signal acquisition and control signal transmission through a single module.\u003c\/p\u003e\n\u003cp\u003eMeanwhile, the input and output circuits have different response times and accuracy specifications. The 10 ms data update period defines the data refresh interval, while the 100 ms input response and 40 ms output response describe the respective step response characteristics.\u003c\/p\u003e\n\u003ch3\u003eTransmitter Wiring and HART Communication\u003c\/h3\u003e\n\u003cp\u003eThe module supports both 2-wire and 4-wire transmitter configurations. Maintenance personnel can select the required wiring mode independently for each channel using the setting pins. In addition, the transmitter power supply specification provides the operating voltage conditions for supported 2-wire transmitter connections.\u003c\/p\u003e\n\u003cp\u003eHART communication is available for digital communication alongside the 4-20 mA analog signal. This allows supported HART field devices to exchange digital information through the analog communication loop.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many input and output channels does the AAI841-H50 provide?\u003c\/p\u003e\n\u003cp\u003eA: It provides 8 analog input channels and 8 analog output channels. Both input and output use 4-20 mA signals.\u003c\/p\u003e\n\u003cp\u003eQ: Does the AAI841-H50 support HART communication?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports HART digital communication in addition to its 4-20 mA analog signal processing.\u003c\/p\u003e\n\u003cp\u003eQ: Can the AAI841-H50 connect to both 2-wire and 4-wire transmitters?\u003c\/p\u003e\n\u003cp\u003eA: Yes. It supports both wiring configurations, with the selection made individually for each channel using setting pins.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\n\u003cimg height=\"17\" width=\"70\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/YOKOGAWA_480x480.png?v=1697472085\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCountry of Origin: Japan\/Singapore\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"17\" width=\"70\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/YOKOGAWA_480x480.png?v=1697472085\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof\u003cspan\u003e \u003cu\u003eYOKOGAWA\u003c\/u\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable height=\"471\" width=\"498\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"188\"\u003e \u003ccol width=\"176\"\u003e \u003ccol width=\"134\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd width=\"188\" height=\"23\" class=\"et2\"\u003eANB10D-425\/CU2N\u003c\/td\u003e\n\u003ctd width=\"176\" class=\"et2\"\u003eSDV144-S63\u003c\/td\u003e\n\u003ctd width=\"134\" class=\"et2\"\u003eSAI143-S53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eAAI143-H50\/K4A00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eALE111-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP451-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eEC402-50 S1\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP471-00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSPW482-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eAAI143-H50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP461-51\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-10 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"45\"\u003e\n\u003ctd height=\"45\" class=\"et2\"\u003eSAI143-H63\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-10\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-50 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eAAI143-H50\/A4S00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI533-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eACG10S-F2121 S4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"23\"\u003e\n\u003ctd height=\"23\" class=\"et2\"\u003eANB10D-420\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSNT401-53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAIP826-2 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAFF50D-H41201\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eADV161-P50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAV144-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSEC402-51\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAI143-S53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-420\/CU2N\/NDEL\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eANB10D-421\/CU2N\/NDEL\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI143-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eADV151-P53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAAI543-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eDP97-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003ePW484-50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eYNT512D-Q12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eCP345\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAAI143-H53\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-410\/S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAB841-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-420 S2\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eNFCP100-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAF135-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP461-51\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP451-10 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAI141-S00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP461-51 S1\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI143-H33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAI141-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP461-51 S2\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSAI143-H03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAI841-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSNB10D-225\/CU2T\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eCP345 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFAR181-S00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAAI141-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eSCP451-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFDV161-P00\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAFV10D-S41211\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003ePW702 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eNFDV161-P50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-421\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eAFV30D-A41452\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"18\"\u003e\n\u003ctd height=\"18\" class=\"et2\"\u003eAAR145-S50\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eANB10D-425\u003c\/td\u003e\n\u003ctd class=\"et2\"\u003eALE111-S50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":68026256916789,"sku":"AAI841-H50","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/AAI841-H50_Cocoai.jpg?v=1793693396","url":"https:\/\/www.newgenplc.com\/az\/products\/yokogawa-aai841-h50-analog-i-o-module","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}