{"product_id":"honeywell-mc-taih12-high-level-analog-input-sti-field-termination-assembly","title":"Honeywell MC-TAIH12 High Level Analog Input\/STI Field Termination Assembly","description":"\u003ch2\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Honeywell_480x480.png?v=1697038586\" alt=\"\" width=\"68\" height=\"13\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell MC-TAIH12\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eMC-TAIH12\u003c\/strong\u003e High Level Analog Input\/STI Field Termination Assembly, terminates up to 16 high-level analog input channels for Honeywell process I\/O systems. The 51304337-150 part number identifies this HLAI\/STI FTA version. Honeywell documentation lists it as an HLAI\/STI FTA with 16 channels and compression terminals. (RuiMingSheng)\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e51304337-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHigh Level Analog Input\/STI Field Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle-ended or differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Function\u003c\/td\u003e\n\u003ctd\u003eHigh-level analog input \/ Smart Transmitter Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eCompression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Size\u003c\/td\u003e\n\u003ctd\u003eSize B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eYes; MC designation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eEstimated shipping size: 30.8 x 12 x 3.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe MC-TAIH12 belongs to Honeywell's HLAI\/STI field termination hardware. Honeywell planning documentation identifies the model as a 16-channel HLAI\/STI assembly with compression terminals and Size B mounting. (RuiMingSheng)\u003c\/p\u003e\n\u003ch3\u003eProcess Analog Signal Interface\u003c\/h3\u003e\n\u003cp\u003eThe MC-TAIH12 accepts high-level analog field signals and provides termination between field wiring and the associated process I\/O hardware. The input channels can use single-ended or differential relationships to logic ground. (Western Process Computers)\u003c\/p\u003e\n\u003cp\u003eFor field wiring, the assembly uses compression terminals. Therefore, installation should maintain the specified terminal arrangement and preserve separation between analog signal conductors and higher-energy wiring.\u003c\/p\u003e\n\u003cp\u003eThe MC-TAIH12 also supports redundant configurations. Honeywell documentation identifies the HLAI\/STI FTA family as supporting redundancy, while the specific 51304337-150 listing identifies 16 input points. (Western Process Computers)\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many analog input channels does the MC-TAIH12 provide?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The MC-TAIH12 provides 16 high-level analog input channels. Honeywell documentation identifies the assembly as an HLAI\/STI, 16-channel FTA. (RuiMingSheng)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of field termination does the MC-TAIH12 use?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The 51304337-150 version uses compression terminals for field wiring. (Western Process Computers)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the MC-TAIH12 support redundant configurations?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The available technical documentation identifies redundancy support for the MC-TAIH12 HLAI\/STI FTA. (Western Process Computers)\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the complete \u003cstrong\u003eMC-TAIH12 \/ 51304337-150\u003c\/strong\u003e identification before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm that the connected I\/O hardware is compatible with the HLAI\/STI FTA configuration.\u003c\/li\u003e\n\u003cli\u003eWire each analog channel according to the applicable Honeywell termination diagram.\u003c\/li\u003e\n\u003cli\u003eKeep analog input wiring separated from AC power, relay output, and high-current conductors.\u003c\/li\u003e\n\u003cli\u003eUse the specified compression-terminal arrangement and check each termination for mechanical security.\u003c\/li\u003e\n\u003cli\u003eRoute shielded analog cables according to the system grounding specification.\u003c\/li\u003e\n\u003cli\u003eAvoid creating multiple unintended shield-ground points that can introduce ground-loop currents.\u003c\/li\u003e\n\u003cli\u003eBefore energization, verify channel polarity, signal reference, terminal assignment, and field-loop continuity.\u003c\/li\u003e\n\u003cli\u003eDo not apply an unspecified field signal or external supply until the associated I\/O documentation confirms the allowable electrical range.\u003c\/li\u003e\n\u003cli\u003eThe manufacturer status supplied for this item is \u003cstrong\u003ediscontinued by manufacturer\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cimg height=\"13\" width=\"68\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Honeywell_480x480.png?v=1697038586\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Honeywell Experion PKS(C200,C300)\u003c\/li\u003e\n\u003cli\u003eCountry of Origin: \u003cspan\u003e USA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLead Time: In Stock, 2 Working Days\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"13\" width=\"68\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/Honeywell_480x480.png?v=1697038586\"\u003e\u003cspan\u003eIn Stock \u003c\/span\u003e\u003cspan\u003eHot Items \u003c\/span\u003eof Honeywell\u003c\/h2\u003e\n\u003ctable width=\"589\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"186\"\u003eFC-SDO-1624\u003c\/td\u003e\n\u003ctd width=\"135\"\u003e8C-PAIH51\u003c\/td\u003e\n\u003ctd width=\"268\"\u003eMC-TAMR03 51309218-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-TSDI-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PAIH51*E\u003c\/td\u003e\n\u003ctd\u003eMC-TAOY22 51204172-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-TSDO-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PAIH52\u003c\/td\u003e\n\u003ctd\u003eMU-TMCN02 561401846-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFS-TSAI-1620M\u003c\/td\u003e\n\u003ctd\u003e8C-PAIN01\u003c\/td\u003e\n\u003ctd\u003eMC-TAIH02 51304453-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFS-TSDI-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PAOH51\u003c\/td\u003e\n\u003ctd\u003eMC-TAIL02 51304437-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-RUSIO-3224\u003c\/td\u003e\n\u003ctd\u003e8C-PAON01\u003c\/td\u003e\n\u003ctd\u003eMC-TDID72 51303928-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-SDI-1624\u003c\/td\u003e\n\u003ctd\u003e8C-PCNT01\u003c\/td\u003e\n\u003ctd\u003eMC-TDODI3 51304650-150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-BKM-0001\u003c\/td\u003e\n\u003ctd\u003e8C-PDIL51\u003c\/td\u003e\n\u003ctd\u003eMC-TDOY23 51204166-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-IO-0001\u003c\/td\u003e\n\u003ctd\u003e8C-PDILAI\u003c\/td\u003e\n\u003ctd\u003eMU-KLAM06 51304465-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-PSU-UNI2450U\u003c\/td\u003e\n\u003ctd\u003e8C-PDOD51\u003c\/td\u003e\n\u003ctd\u003eMU-TAIH02 51304453-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-QPP-0001\u003c\/td\u003e\n\u003ctd\u003e8C-TAID51\u003c\/td\u003e\n\u003ctd\u003eMU-TAMR03 501309218-125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-SAI-1620M\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX51\u003c\/td\u003e\n\u003ctd\u003eMU-TAOX12 51304335-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFC-USI-0001\u003c\/td\u003e\n\u003ctd\u003e8C-TAIX61\u003c\/td\u003e\n\u003ctd\u003eMU-TDID72 51303928-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-PAOX01\u003c\/td\u003e\n\u003ctd\u003e8C-TAOX61\u003c\/td\u003e\n\u003ctd\u003eMU-TDOD12 51304423-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-PFB801\u003c\/td\u003e\n\u003ctd\u003e8C-TCNT01\u003c\/td\u003e\n\u003ctd\u003eMU-TDOR22 51304427-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-PPIX01\u003c\/td\u003e\n\u003ctd\u003eTC-CCN013\u003c\/td\u003e\n\u003ctd\u003eDC-TFB412 51307618-176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCC-TAID11\u003c\/td\u003e\n\u003ctd\u003eTC-CCR012\u003c\/td\u003e\n\u003ctd\u003eTK-IOLI01 51403427-175 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC-TAOX11\u003c\/td\u003e\n\u003ctd\u003eTC-IAH161\u003c\/td\u003e\n\u003ctd\u003eTK-PPD011 51309241-175 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC-IDJ161\u003c\/td\u003e\n\u003ctd\u003eTC-OAV081\u003c\/td\u003e\n\u003ctd\u003eTK-PRS021 51404305-275 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC-IXL061\u003c\/td\u003e\n\u003ctd\u003e10300\/1\/1\u003c\/td\u003e\n\u003ctd\u003eCC-TAIX01 51308363-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDCS3000LCN\u003c\/td\u003e\n\u003ctd\u003e51305887-150\u003c\/td\u003e\n\u003ctd\u003e8C-PAOHA1 51454469-275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTK-FPDXX2\u003c\/td\u003e\n\u003ctd\u003e10012\/1\/2\u003c\/td\u003e\n\u003ctd\u003e8C-PAIMA1 51454473-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53631958974773,"sku":"51304337-150 (Rev V)","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/51304337-150_RevV__Cocoai.jpg?v=1790149463","url":"https:\/\/www.newgenplc.com\/ar\/products\/honeywell-mc-taih12-high-level-analog-input-sti-field-termination-assembly","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}