{"product_id":"mtl-mtl831b-is-analogue-multiplexer-transmitte","title":"MTL MTL831B IS Analogue Multiplexer Transmitte","description":"\u003ch2\u003e\n\u003cimg height=\"45\" width=\"72\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/R.png?v=1716283560\" alt=\"\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eMTL MTL831B\u003c\/strong\u003e IS Analogue Multiplexer Transmitter enables safe and efficient signal transmission from multiple field devices in hazardous environments. It is engineered for precision and reliability, ensuring that process measurements are accurately transmitted to control systems. Moreover, its intrinsic safety design allows deployment in areas with potentially explosive atmospheres. Engineers trust it for both new installations and system upgrades.\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003e\u003cspan\u003e\u003cspan style=\"font-family: 微软雅黑;\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMTL831B IS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalogue Multiplexer Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eUp to 16 single-ended or 8 differential channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e0–20 mA, 4–20 mA, or 0–10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA or 0–20 mA loop-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and input-to-output galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypical: 1.5 W per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% – 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e115 mm x 100 mm x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eATEX, IECEx, FM, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;100 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Compliance\u003c\/td\u003e\n\u003ctd\u003eIEC 61010-1, IEC 60079\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicators\u003c\/td\u003e\n\u003ctd\u003eLED status for power, channel activity, and fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What hazardous areas is the MTL831B suitable for?\u003c\/strong\u003e\u003cbr\u003eA1: It is certified for Zone 0, 1, and 2 hazardous areas under ATEX, IECEx, FM, and CSA standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How many channels can it multiplex?\u003c\/strong\u003e\u003cbr\u003eA2: Up to 16 single-ended or 8 differential channels can be transmitted simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What signal types are supported?\u003c\/strong\u003e\u003cbr\u003eA3: Standard analogue signals, including 0–20 mA, 4–20 mA, and 0–10 V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can it be mounted in a standard DIN rail cabinet?\u003c\/strong\u003e\u003cbr\u003eA4: Yes, it supports DIN rail and panel mounting for flexible installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Is maintenance difficult?\u003c\/strong\u003e\u003cbr\u003eA5: No, plug-in modules and LED indicators simplify calibration, replacement, and fault diagnostics.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\n\u003cimg height=\"37\" width=\"60\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/R.png?v=1716283560\"\u003eOther Attributes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCountry of Origin: France\u003cbr\u003eLead Time:\u0026amp;nbsp;In Stock, 2 Working Days\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/R.png?v=1716283560\" width=\"57\" height=\"36\"\u003eOur Competitive Brands\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e- ABB Advant-800xA，Advant OCS，Bailey Infi 90 and Net 90，H\u0026amp;B Freelance 2000，DSQC Robots，IGCT \/ IGBT\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- GE General Electric Field Control, Genius I\/O, QuickPanel, RX3i PacSystem, Series 90, Series 90, Series VersaMax\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Allen Bradley Allen-Bradley SLC500, MicroLogix, CompactLogix, ControlLogix, PLC-5, Panel View,\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Bently Nevada 3300 System, 3500 System\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Honeywell 7800 Series, FSC, IPC, Mxopen, TDC 2000, TDC 3000, Experion PKS(C200,C300)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Yokogawa Centum CS - Centum VP, Centum XL - micro XL, FA-M3, ProSafe-PLC\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e- Ovation, Foxboro, EPRO, Emerson DeltaV, Fuji, Siemens, HIMA, Prosoft, Invensys Triconex, ICS TRIPLEX, Woodward, Bachmann, Schneider\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"tel:+8618030205725\"\u003e\u003cspan\u003e\u003cstrong\u003eTEL: +86 18030205725 \u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e    \u003ca href=\"maito:manskiwong@cambia.cn\"\u003e\u003cspan\u003e\u003cstrong\u003eE-MAIL: manskiwong@cambia.cn\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"MTL","offers":[{"title":"Default Title","offer_id":52220736078133,"sku":"MTL831B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0834\/0789\/6885\/files\/MTLMTL831BISAnalogueMultiplexerTransmitte.jpg?v=1768558615","url":"https:\/\/www.newgenplc.com\/af\/products\/mtl-mtl831b-is-analogue-multiplexer-transmitte","provider":"New-Gen Automation Limited","version":"1.0","type":"link"}